<sup>3</sup>From the Minimal Impact Design Standards (MIDS) calculator, which assumes phosphorus in runoff is 55 percent particulate, 45 percent dissolved, and that removal efficiency is 45 percent for particulate fraction and 0 percent for dissolved fraction.</font size> | <sup>3</sup>From the Minimal Impact Design Standards (MIDS) calculator, which assumes phosphorus in runoff is 55 percent particulate, 45 percent dissolved, and that removal efficiency is 45 percent for particulate fraction and 0 percent for dissolved fraction.</font size> | ||
<noinclude>[[category:table]]</noinclude> | <noinclude>[[category:table]]</noinclude> |
Pollutant removal percentages for bioretention BMPs. Source Winer, 2000.
Link to this table
Practice | TSS | Total Phosphorus | Total nitrogen | Metals1 | Bacteria | Hydrocarbons |
---|---|---|---|---|---|---|
Bioretention1 | 852 |
|
50 | 95 | 352 | 80 |
1 Average of zinc and copper
2 Assumed values based on filtering practice performance
3From the Minimal Impact Design Standards (MIDS) calculator, which assumes phosphorus in runoff is 55 percent particulate, 45 percent dissolved, and that removal efficiency is 45 percent for particulate fraction and 0 percent for dissolved fraction.