<td>Wet swale</td>
 
<td>Wet swale</td>
 
<td>[[File:Watershed tab for wet swale.png|100px|alt=Screen shot of the Watershed tab for Wet swale]]</td>
 
<td>[[File:Watershed tab for wet swale.png|100px|alt=Screen shot of the Watershed tab for Wet swale]]</td>
<td>Sedimentation / Infiltration</td>
+
<td>Sedimentation / Transpiration</td>
<td>End</td>
+
<td>throughout</td>
<td>TSS: High
+
<td>
TN: Medium/High
+
:TSS: Medium
TP: Medium/High
+
:TN: Low
Chloride: Low
+
:TP: Low
Metals: High
+
:Chloride: Low
Oils and Grease: High
+
:Metals: Low
Pathogens: High</td>
+
:Oils and Grease: Low
<td>Residential: Yes
+
:Pathogens: Low</td>
Commercial: Yes
+
<td>
Ultra Urban: Limited
+
:Residential
Industrial: Limited
+
:Commercia
Retrofit: Yes
+
:Ultra Urban
Highway/Road: Limited</td>
+
:Industrial
 +
:Highway/Road
 +
:Recreation</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>

Revision as of 14:58, 14 March 2018

Stormwater filtration BMPs - treatment properties
Link to this table

Stormwater BMP Illustration Pollutant Removal Mechanism Location in Treatment Train Pollutant Removal 1,2 Potential Application 1
Dry swale or step pool image dry swale Sedimentation / Infiltration Throughout
TSS: Medium
TN: Low
TP: Medium
Chloride: Low
Metals: Medium
Oils and Grease: Low
Pathogens: Low
Residential
Commercial
Industrial
Ultra Urban
Highway/Road
Recreational
Wet swale Screen shot of the Watershed tab for Wet swale Sedimentation / Transpiration throughout
TSS: Medium
TN: Low
TP: Low
Chloride: Low
Metals: Low
Oils and Grease: Low
Pathogens: Low
Residential
Commercia
Ultra Urban
Industrial
Highway/Road
Recreation
Biofiltration Basin
Bioinfiltration icon.png
Sedimentation / Infiltration Beginning TSS: High

TN: Low/Medium TP: Medium/High Chloride: Low Metals: High

Oils and Grease: High
Residential: Yes

Commercial: Yes Ultra Urban: Limited Industrial: Limited Retrofit: Yes

Highway/Road: Limited
Permeable pavement with underdrain
Permeable pavement icon.png
Infiltration Beginning TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High

Oils and Grease: High
Residential: Yes

Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes

Highway/Road: Limited
Tree Trench/Tree Box (with underdrain)
Tree trench icon.png
Infiltration, Transpiration Throughout TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High

Pathogens: High
Residential: Limited

Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes

Highway/Road: Limited
Green roof TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High

Pathogens: High
Residential: Yes

Commercial: Yes Ultra Urban: Yes Industrial: Yes Retrofit: Yes

Highway/Road: No

1 Treatment Capabilities and Potential Applications referenced from Manual Section BMP's for stormwater infiltration
2 Low = < 30%; Medium = 30‐65%; High = 65‐100%