m |
m |
||
Line 19: | Line 19: | ||
<td>No</td> | <td>No</td> | ||
<td></td> | <td></td> | ||
− | <td>Inlet flush with street surface, see detailed schematic</td> | + | <td>Inlet flush with street surface, [http://www.rainguardian.biz/images/Handouts/RAIN_GUARDIAN_BUNKER_1'_TYPICAL_DETAIL_11X17.pdf see detailed schematic]</td> |
− | <td>See detailed schematic</td> | + | <td>[http://www.rainguardian.biz/images/Handouts/RAIN_GUARDIAN_BUNKER_1'_TYPICAL_DETAIL_11X17.pdf See detailed schematic]</td> |
<td></td> | <td></td> | ||
</tr> | </tr> | ||
Line 29: | Line 29: | ||
<td>Yes</td> | <td>Yes</td> | ||
<td></td> | <td></td> | ||
− | <td>Inlet flush with street surface, See detailed schematic</td> | + | <td>Inlet flush with street surface, See detailed schematic [http://www.rainguardian.biz/images/Handouts/RAIN_GUARDIAN_TURRET_1'_TYPICAL_DETAIL_11X17_FIBERGLASS_GRATE.pdf]</td> |
− | <td>See detailed schematic</td> | + | <td>See detailed schematic [http://www.rainguardian.biz/images/Handouts/RAIN_GUARDIAN_TURRET_1'_TYPICAL_DETAIL_11X17_FIBERGLASS_GRATE.pdf]</td> |
<td></td> | <td></td> | ||
</tr> | </tr> | ||
Line 39: | Line 39: | ||
<td>No</td> | <td>No</td> | ||
<td></td> | <td></td> | ||
− | <td>See detailed schematic</td> | + | <td>See detailed schematic [http://www.rainguardian.biz/images/Handouts/RAIN_GUARDIAN_FOXHOLE_TYPICAL_DETAIL_01-11-18.pdf]</td> |
<td></td> | <td></td> | ||
<td></td> | <td></td> | ||
Line 51: | Line 51: | ||
<td>NA</td> | <td>NA</td> | ||
<td>NA</td> | <td>NA</td> | ||
− | <td>Optional shallow pool upstream of check</td> | + | <td>Optional shallow pool upstream of check [https://stormwater.pca.state.mn.us/index.php?title=Sediment_control_practices_-_Check_dams_(ditch_checks,_ditch_dikes)]</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 65: | Line 65: | ||
<tr> | <tr> | ||
<td>Hydro Screen (multiple model sizes)</td> | <td>Hydro Screen (multiple model sizes)</td> | ||
− | <td>Commercial, Industrial, Residential, Agricultural</td> | + | <td>Commercial, Industrial, Residential, Agricultural [http://www.hydroscreen.com/products/index.html#sthash.ZMy5cd4J.dpbs]</td> |
<td></td> | <td></td> | ||
<td>Yes</td> | <td>Yes</td> |
Screening and straining devices - system and component sizing
Link to this table
Device | Land use | Downstream BMP (type) | Enhancement opportunity | Sizing calculations | Inlets | Outlets | Flow diversion structures |
---|---|---|---|---|---|---|---|
Rain Guardian - Bunker | Residential (recommended) | Bioretention | No | Inlet flush with street surface, see detailed schematic | See detailed schematic | ||
Rain Guardian - Turret | Commercial and Industrial areas | Bioretention | Yes | Inlet flush with street surface, See detailed schematic [1] | See detailed schematic [2] | ||
Rain Guardian - Foxhole | Multiple/various | Bioretention | No | See detailed schematic [3] | |||
Riprap check dams | Multiple/various | No | NA | NA | Optional shallow pool upstream of check [4] | ||
Wattles | Multiple/various | No | Depends on application | NA | NA | NA | |
Hydro Screen (multiple model sizes) | Commercial, Industrial, Residential, Agricultural [5] | Yes | Depends on application | NA | NA | Depends on model, most have bypass capabilities |