(Mtrojan uploaded a new version of File:Solar panels 1.png) |
|||
(11 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
+ | Rain falls on the solar panel and runs off to the edge of the panel, where it falls vertically at the dripline to the ground below. From there this water can infiltrate or move along the ground surface toward the next panel. The area beneath the panel and between panels consists of pervious soil with well-maintained vegetation. Water falling from a panel can therefore infiltrate from the dripline until it encounters the next dripline, where additional water is supplied from the next panel. Panels can be rotated from the horizontal position. α measures the angle of rotation from the horizontal position. Because the panel rotates, the length Z, which represents the horizontal distance beneath a panel, varies. The average value for Z is given by | ||
+ | <math> Z = (COS(α max)H + COS(α min)H) / 2 </math> | ||
+ | |||
+ | where H is the horizontal length of the panel. Y, which is the pervious length between panels, can vary depending on the angle of panel rotation, so for simplicity of calculations Y should be based on the average value of Z. |
Rain falls on the solar panel and runs off to the edge of the panel, where it falls vertically at the dripline to the ground below. From there this water can infiltrate or move along the ground surface toward the next panel. The area beneath the panel and between panels consists of pervious soil with well-maintained vegetation. Water falling from a panel can therefore infiltrate from the dripline until it encounters the next dripline, where additional water is supplied from the next panel. Panels can be rotated from the horizontal position. α measures the angle of rotation from the horizontal position. Because the panel rotates, the length Z, which represents the horizontal distance beneath a panel, varies. The average value for Z is given by
\( Z = (COS(α max)H + COS(α min)H) / 2 \)
where H is the horizontal length of the panel. Y, which is the pervious length between panels, can vary depending on the angle of panel rotation, so for simplicity of calculations Y should be based on the average value of Z.
Click on a date/time to view the file as it appeared at that time.
(newest | oldest) View (newer 10 | older 10) (10 | 20 | 50 | 100 | 250 | 500)Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 12:50, 24 March 2016 | 1,259 × 824 (107 KB) | Mtrojan (talk | contribs) | ||
12:49, 24 March 2016 | 1,259 × 824 (107 KB) | Mtrojan (talk | contribs) | |||
12:28, 24 March 2016 | 1,259 × 824 (107 KB) | Mtrojan (talk | contribs) | Reverted to version as of 12:26, 24 March 2016 | ||
12:27, 24 March 2016 | 1,259 × 824 (107 KB) | Mtrojan (talk | contribs) | |||
12:26, 24 March 2016 | 1,259 × 824 (107 KB) | Mtrojan (talk | contribs) | |||
19:28, 23 March 2016 | 1,278 × 764 (98 KB) | Mtrojan (talk | contribs) | |||
19:56, 11 March 2016 | 1,273 × 703 (91 KB) | Mtrojan (talk | contribs) | |||
19:54, 11 March 2016 | 1,273 × 703 (90 KB) | Mtrojan (talk | contribs) | |||
15:20, 11 March 2016 | 1,273 × 703 (90 KB) | Mtrojan (talk | contribs) | |||
14:36, 11 March 2016 | 1,273 × 914 (100 KB) | Mtrojan (talk | contribs) |
You cannot overwrite this file.
The following 2 pages use this file:
This file contains additional information, probably added from the digital camera or scanner used to create or digitize it.
If the file has been modified from its original state, some details may not fully reflect the modified file.
Horizontal resolution | 59.06 dpc |
---|---|
Vertical resolution | 59.06 dpc |
Software used |
|
This page was last edited on 14 February 2020, at 21:54.