m |
|||
(49 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | <font size=3>'''Summary of properties of permeable pavements.'''</font size><br> | ||
+ | Link to this [[Properties of permeable pavement|table]] | ||
− | < | + | <table class="sortable"> |
− | + | <tr> | |
− | + | <th>Properties</th> | |
− | <tr | ||
− | <th | ||
<th>Pervious concrete</th> | <th>Pervious concrete</th> | ||
<th>Porous asphalt</th> | <th>Porous asphalt</th> | ||
Line 10: | Line 10: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Typical pavement surface thickness<sup> | + | <td width="25%">Typical pavement surface thickness<sup>a</sup></td> |
<td width="25%">5 to 8 inches</td> | <td width="25%">5 to 8 inches</td> | ||
<td width="25%">3 to 4 inches (thicker for high wheel load applications)</td> | <td width="25%">3 to 4 inches (thicker for high wheel load applications)</td> | ||
− | <td width="25%">3 inches</td> | + | <td width="25%">3 inches<sup>a</sup></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Bedding layer<sup> | + | <td width="25%">Bedding layer<sup>a,f</sup></td> |
<td width="25%">None</td> | <td width="25%">None</td> | ||
− | <td width="25%">1 in. No. 57 stone</td> | + | <td width="25%">1 in. [https://unionquarries.com/products/aggregate-types/aashto-57/ AASHTO No. 57 stone]</td> |
− | <td width="25%">2 inches of No. 8 stone</td> | + | <td width="25%">2 inches of [https://unionquarries.com/products/aggregate-types/aashto-8/ AASHTO No. 8 stone] (MnDOT 3127 FA-3)</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Reservoir layer<sup> | + | <td width="25%">Reservoir layer<sup>b,f</sup></td> |
− | <td width="25%">No. 57 stone or per hydraulic design | + | <td width="25%">AASHTO No. 57 stone or per hydraulic design</td> |
− | <td width="25%">No. 2, 3, or 5 stone</td> | + | <td width="25%">[https://www.nesl.com/wp-content/uploads/2019/06/Product-Description-and-Uses_PA-stone.pdf AASHTO No. 2, 3, or 5 stone]</td> |
− | <td width="25%">4 inches of No. 57 stone over No. 2, 3 or 4 stone</td> | + | <td width="25%">4 inches of [https://www.nesl.com/wp-content/uploads/2019/06/Product-Description-and-Uses_PA-stone.pdf AASHTO No. 57 stone over No. 2, 3 or 4 stone]</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td width="25%">Construction properties</td> | <td width="25%">Construction properties</td> | ||
− | <td width="25%">Cast in place | + | <td width="25%"> |
− | <td width="25%">Cast in place | + | *Cast in place |
− | <td width="25%">No cure period | + | *Seven day cure |
+ | *Must be continuously covered</td> | ||
+ | <td width="25%"> | ||
+ | *Cast in place | ||
+ | *24 hour cure</td> | ||
+ | <td width="25%"> | ||
+ | *No cure period | ||
+ | *Manual or mechanical installation of pre-manufactured units</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Installed surfacing cost<sup> | + | <td width="25%">Installed surfacing cost<sup>c</sup></td> |
− | <td width="25%"> | + | <td width="25%">3 to $4/square foot</td> |
− | <td width="25%"> | + | <td width="25%">$2/square foot</td> |
− | <td width="25%"> | + | <td width="25%">3 to $4/square foot</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td width="25%">Minimum batch size</td> | <td width="25%">Minimum batch size</td> | ||
− | <td | + | <td colspan="3"><center>None</center></td> |
− | |||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Longevity<sup> | + | <td width="25%">Longevity<sup>d</sup></td> |
− | <td | + | <td colspan="3"><center>20 to 30 years</center></td> |
− | |||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td width="25%">Overflow</td> | <td width="25%">Overflow</td> | ||
− | <td | + | <td colspan="3"><center>Catch basin, overflow edge, elevated underdrain</center></td> |
− | < | ||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td width="25%">Runoff temperature reduction</td> | <td width="25%">Runoff temperature reduction</td> | ||
− | <td | + | <td colspan="3"><center>Cooling at the reservoir layer</center></td> |
− | |||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 70: | Line 69: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Load bearing capacity<sup> | + | <td width="25%">Load bearing capacity<sup>e</sup></td> |
− | <td | + | <td colspan="3"><center>Handles all vehicle loads with appropriate surface and base/subbase layer material and thickness design</center></td> |
− | < | ||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Surface cleaning<sup> | + | <td width="25%">Surface cleaning<sup>g</sup></td> |
− | <td | + | <td colspan="2"><center>Periodic vacuuming; replace if completely clogged and uncleanable</center></td> |
− | |||
<td width="25%">Periodic vacuuming; replace jointing stones if completely clogged and uncleanable</td> | <td width="25%">Periodic vacuuming; replace jointing stones if completely clogged and uncleanable</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td width="25%">Other issues</td> | <td width="25%">Other issues</td> | ||
− | <td width="25%">Avoid concentrated deicers | + | <td width="25%"> |
− | <td width="25%">Avoid seal coating | + | *Avoid concentrated deicers |
+ | *Avoid winter sanding</td> | ||
+ | <td width="25%"> | ||
+ | *Avoid seal coating | ||
+ | *Avoid winter sanding</td> | ||
<td width="25%">Avoid winter sanding</td> | <td width="25%">Avoid winter sanding</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td width="25%">Design | + | <td width="25%">Design references</td> |
− | <td width="25%">[ | + | <td width="25%">[https://core.ac.uk/download/pdf/215464202.pdf]</td> |
− | <td width="25%"> | + | <td width="25%">[https://www.unh.edu/unhsc/sites/unh.edu.unhsc/files/pubs_specs_info/unhsc_pa_spec_10_09.pdf]</td> |
− | <td width="25%"> | + | <td width="25%">[https://www.fhwa.dot.gov/pavement/concrete/pubs/hif19021.pdf]</td> |
</tr> | </tr> | ||
</table> | </table> | ||
+ | <font size = 1><sup>a</sup>Thickness may vary depending on site and traffic conditions<br> | ||
+ | <sup>b</sup>Reservoir storage may be augmented by corrugated metal pipes, plastic arch pipe or plastic lattice crates<br> | ||
+ | <sup>c</sup>Supply and install minimum surface thickness only; minimum 30,000 sf with Minnesota 2012 prevailing labor wages. Does not include base reservoir, drainage appurtenances, engineering, or inspection<br> | ||
+ | <sup>d</sup>Based on pavement being properly maintained. Resurfacing or rehabilitation may be needed after the indicated period<br> | ||
+ | <sup>e</sup>Depends primarily on on-site geotechnical considerations and structural design computations<br> | ||
+ | <sup>f</sup> ASTM D448 Standard Classification for Sizes of Aggregate for Road and Bridge Construction or ASASHTO M-43<br> | ||
+ | <sup>g</sup>Periodic vacuuming frequency determined from inspection, intensity of use, and other potential sediment sources | ||
+ | </font size> | ||
− | < | + | <noinclude>[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Permeable pavement]]</noinclude> |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | </ |
Summary of properties of permeable pavements.
Link to this table
Properties | Pervious concrete | Porous asphalt | PICP |
---|---|---|---|
Typical pavement surface thicknessa | 5 to 8 inches | 3 to 4 inches (thicker for high wheel load applications) | 3 inchesa |
Bedding layera,f | None | 1 in. AASHTO No. 57 stone | 2 inches of AASHTO No. 8 stone (MnDOT 3127 FA-3) |
Reservoir layerb,f | AASHTO No. 57 stone or per hydraulic design | AASHTO No. 2, 3, or 5 stone | 4 inches of AASHTO No. 57 stone over No. 2, 3 or 4 stone |
Construction properties |
|
|
|
Installed surfacing costc | 3 to $4/square foot | $2/square foot | 3 to $4/square foot |
Minimum batch size | |||
Longevityd | |||
Overflow | |||
Runoff temperature reduction | |||
Surface colors/texture | Range of light colors and textures | Black or dark grey colors | Wide range of colors, textures and patterns |
Load bearing capacitye | |||
Surface cleaningg | Periodic vacuuming; replace jointing stones if completely clogged and uncleanable | ||
Other issues |
|
|
Avoid winter sanding |
Design references | [1] | [2] | [3] |
aThickness may vary depending on site and traffic conditions
bReservoir storage may be augmented by corrugated metal pipes, plastic arch pipe or plastic lattice crates
cSupply and install minimum surface thickness only; minimum 30,000 sf with Minnesota 2012 prevailing labor wages. Does not include base reservoir, drainage appurtenances, engineering, or inspection
dBased on pavement being properly maintained. Resurfacing or rehabilitation may be needed after the indicated period
eDepends primarily on on-site geotechnical considerations and structural design computations
f ASTM D448 Standard Classification for Sizes of Aggregate for Road and Bridge Construction or ASASHTO M-43
gPeriodic vacuuming frequency determined from inspection, intensity of use, and other potential sediment sources
This page was last edited on 15 August 2022, at 20:44.