(57 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{alert|The anticipated construction period for this page is through August, 2014|alert-under-construction}}
+
[[File:Pdf image.png|100px|thumb|alt=pdf image|<font size=3>[https://stormwater.pca.state.mn.us/index.php?title=File:Requirements,_recommendations_and_information_for_using_bioretention_with_an_underdrain_BMPs_in_the_MIDS_calculator_-_Minnesota_Stormwater_Manual_feb_2021.pdf Download pdf]</font size>]]
 +
[[File:Symbol for biofiltration with an underdrain.jpg|300px|thumb|alt=Symbol for Bioretention basin (with underdrain)) used in MIDS calculator|<font size=3>Symbol for Bioretention basin (with underdrain) used in MIDS calculator.</font size>]]
 +
[[File:Watershed tab bioretention with underdrain.png|300px|thumb|alt=Screen shot of Watershed tab for bioretention with underdrain. The user must input a value for impervious area or the BMP will not provide volume and pollutant reduction. Other fields are optional.|<font size=3>Screen shot Watershed tab for Bioretention basin (with underdrain).The user must input a value for impervious area or the BMP will not provide volume and pollutant reduction. Other fields are optional.</font size>]]
 +
[[File:User inputs tab for bioretention with underdrain.png|300px|thumb|alt=Screen shot of the BMP Parameters tab for a Bioretention basin (with underdrain). The user must enter values for all blank cells.|<font size=3>Screen shot of the BMP Parameters tab for a Bioretention basin (with underdrain). The user must enter values for all blank cells.</font size>]]
  
[[File:Symbol for biofiltration with an underdrain.jpg|300px|thumb|alt=Symbol for biofiltration (Bioretention basin (with underdrain)) in MIDS calculator|<font size=3>Symbol for biofiltration (Bioretention basin (with underdrain)) in MIDS calculator.</font size>]]
+
For a bioretention (aka biofiltration) BMP with an underdrain at the bottom of the engineered media, most of the stormwater captured by the BMP is filtered and lost to the [[Glossary#U|underdrain]]. However, some stormwater infiltrates through the basin bottom and sidewalls if these do not have an impermeable liner. Volume retention also occurs by [[Glossary#E|evapotranspiration]] through the vegetation in the biofiltration BMP.  For [[Bioretention terminology|biofiltration]] systems with an elevated underdrain, additional volume retention is achieved through [[Glossary#I|infiltration]] of water stored in the pore spaces of the engineered media between the underdrain invert and the native soils. All pollutants in infiltrated water are credited as being removed, while a portion of the pollutant loads in the stormwater that flows through the underdrain are removed through [[Glossary#F|filtration]].
[[File:Watershed tab bioretention with underdrain.png|300px|thumb|alt=Screen shot watershed tab bioretention with underdrain|<font size=3>Screen shot of the watershed tab for bioretention with an underdrain.</font size>]]
 
[[File:User inputs tab for bioretention with underdrain.png|300px|thumb|alt=Screen shot from MIDS calculator showing user inputs needed for a biofiltration basin|<font size=3>Screen shot from MIDS calculator showing user inputs needed for a biofiltration basin</font size>]]
 
  
For a biofiltration BMP with an underdrain at the bottom, most of the stormwater captured by the BMP is lost to the [[Glossary#U|underdrain]]. However, some stormwater infiltrates through the basin bottom and sidewalls if these do not have an impermeable liner. [[Glossary#E|Evapotranspiration]] also occurs from vegetation in the biofiltration BMP.  For a biofiltration system with an elevated underdrain, in addition to volume losses through the sidewalls and through evapotranspiration, the water stored between the underdrain and the native soils is captured and infiltrated.  In a bioretention BMP with an underdrain, all pollutants in infiltrated water are removed, while pollutants are removed through filtration for the water that flows through an underdrain.
+
NOTE: A bioretention device with an installed underdrain is a type of [[Glossary#B|biofiltration]] device, since some portion of the treated water is filtered and discharged downstream rather than infiltrated. MPCA believes that biofiltration is the more generally applicable term for this BMP type; but the reader will currently find both of these terms on relevant pages, due to MPCA's understanding that [[Bioretention_terminology|a variety of terms]] are currently common in stormwater management.  
  
===MIDS calculator user inputs for biofiltration===
+
==Version 4 changes==
 +
{{alert|Updates have been made to Version 4 of the MIDS Calculator|alert-info}}
  
For biofiltration systems, the user must input the following parameters to calculate the volume and pollutant load reductions associated with the BMP.
+
*'''The USER must enter a bypass percent for this BMP.''' [https://stormwater.pca.state.mn.us/index.php?title=Estimating_and_calculating_bypass_for_the_Minimal_Impact_Design_Standards_(MIDS)_Calculator See the guidance for determining bypass percent.]
 +
*The question ''Is a soil amendment used to attenuate phosphorus?'' was changed to ''Do you have a properly designed phosphorus treatment layer or area in your system (e.g. iron enhanced layer)?''. Currently, the only option for incorporating an amendment to retain phosphorus is to install [https://stormwater.pca.state.mn.us/index.php?title=Design_criteria_for_bioretention#Layered_systems a treatment layer below the bioretention media]. This typically is a layer containing 5-8 percent iron [https://stormwater.pca.state.mn.us/index.php?title=Design_criteria_for_iron_enhanced_sand_filter (link here for more information on iron-enhanced systems)]. [https://www.wrc.umn.edu/biofiltration-media-optimization-phase-ii-multi-year-performance-impacts-road-salt-and-optimized Research is currently being done] to determine if amendments can be incorporated directly into the bioretention media.
 +
*When an amendment is added to the practice, the particulate phosphorus removal was changed from 0 to 40 percent. This was error in previous versions of the calculator.
  
*'''Watershed tab'''
+
===MIDS calculator user inputs for biofiltration basin (with underdrain)===
 +
 
 +
For a biofiltration with underdrain system, the user must input the following parameters to calculate the volume and pollutant load reductions associated with the BMP.
 +
 
 +
*'''Watershed tab:'''
 
**'''BMP Name:''' this cell is auto-filled but can be changed by the user.
 
**'''BMP Name:''' this cell is auto-filled but can be changed by the user.
**'''Routing/downstream BMP:''' if this BMP is part of a treatment train and water is being routed from this BMP to another BMP, the user selects the name of the BMP from the dropdown box to which water is being routed.  All water must be routed to a single downstream BMP. Note that the user must include the BMP receiving the routed water in the Schematic or the BMP will not appear in the dropdown box.
+
**'''Routing/downstream BMP:''' if this BMP is part of a [[Using the treatment train approach to BMP selection|treatment train]] and water is being routed from this BMP to another BMP, the user selects the name of the BMP to which water is being routed from the dropdown box.  All water must be routed to a single downstream BMP. Note that the user must include the BMP receiving the routed water in the Schematic or the BMP will not appear in the dropdown box.
**'''BMP Watershed Area:''' BMP watershed areas are the areas draining directly to the BMP. Values can be added for four soil types ([[Glossary#H|Hydrologic Soil Groups]] (HSG) A, B, C, D) and for three Land Cover types (Forest/Open Space, Managed Turf and impervious).  The surface area of the BMP should be included as a managed turf land cover under the hydrologic soils group of the native soils located under the BMP. Units are in acres.
+
**'''BMP Watershed Area:''' BMP watershed areas are the areas draining directly to the BMP. Values can be added for four soil types ([[Glossary#H|Hydrologic Soil Groups]] (HSG) A, B, C, D) and for three Land Cover types (Forest/Open Space, Managed Turf, and Impervious).  The surface area of the BMP should be included as a managed turf land cover of the hydrologic soil type of the native soils that are located under the BMP. Units are in acres.
  
*'''BMP Parameters tab'''
+
*'''BMP Parameters tab:'''
**'''Is the underdrain elevated above native soils?:''' This is a YES/NO question.  Answering YES means the underdrain is elevated within the media (i.e., [[Bioretention terminology|Biofiltration with a raised underdrain]]).  This creates storage capacity between the underdrain and the native soils.  Answering NO means that the underdrain is not elevated within the media and is directly above the native soils with no storage capacity below the underdrain (i.e., Biofiltration with underdrain at the bottom).
+
**'''Is the underdrain elevated above native soils?:''' This is a YES/NO question.  Answering YES means the underdrain is elevated within the media (i.e., [[Bioretention terminology|Biofiltration with a raised underdrain]]).  This creates storage capacity between the underdrain and the native soils.  Answering NO means that the underdrain is not elevated within the media and is directly above the native soils with no storage capacity below the underdrain (i.e., [[Bioretention terminology|Biofiltration with underdrain at the bottom]]).
 
**'''Are the sides of the basin lined with an impermeable liner?:''' This is a YES/NO question.  Answering YES means the sides of the basin are lined, preventing water from infiltrating into the native soils.  Answering NO means the sides are not lined and infiltration is allowed through the side of the basin into the native soils.
 
**'''Are the sides of the basin lined with an impermeable liner?:''' This is a YES/NO question.  Answering YES means the sides of the basin are lined, preventing water from infiltrating into the native soils.  Answering NO means the sides are not lined and infiltration is allowed through the side of the basin into the native soils.
**'''Is the bottom of the basin lined with an impermeable liner?''':  This is a YES/NO question.  Answering YES means the bottom of the basin is lined, preventing water from infiltration into the native soils.  Answering NO means the bottom is not lined and infiltration is allowed through the bottom of the basin into the native soils.
+
**'''Is the bottom of the basin lined with an impermeable liner?''':  This is a YES/NO question.  Answering YES means the bottom of the basin is lined, preventing water from infiltrating into the native soils.  Answering NO means the bottom is not lined and infiltration is allowed through the bottom of the basin into the native soils.
**'''Surface area at overflow (A<sub>O</sub>):''' This is the surface area of the BMP at the lowest outlet point of the surface overflow from the ponding area of the BMP. The user inputs this value in square feet.  
+
**'''Surface area at overflow (A<sub>O</sub>):''' This is the surface area of the BMP at the lowest outlet point of the surface overflow from the ponding area of the BMP. Units are in square feet.  
**'''Surface area at media surface (A<sub>m</sub>):''' This is the surface area at the bottom of the ponded water within the BMP. This is therefore the area at the surface of the engineered media. The user inputs this value in square feet.
+
**'''Media surface area (A<sub>M</sub>):''' This is the surface area at the bottom of the ponded water within the BMP. This is therefore the area at the surface of the [[Design criteria for bioretention#Materials specifications - filter media|engineered media]]. Units are in square feet.
**'''Overflow depth (D<sub>O</sub>):''' This is the maximum depth of ponded water within the BMP (i.e., distance from the overflow elevation to the top of the soil or media). The user inputs this value in feet. The maximum value allowed for this depth is 1.5 feet.
+
**'''Surface area at underdrain (A<sub>U</sub>):''' This is the surface area of the BMP at the invert elevation of the underdrain. If the response to ''"Is the underdrain elevated above native soils?"'' is set to NO, then this cell will become inactive and populated with the ''Bottom surface area'' value. Units are in square feet.
**'''Surface area at underdrain (A<sub>U</sub>):''' This is the surface area of the BMP at the invert elevation of the underdrain. If the response to ''Is the underdrain elevated above native soils?'' is set to NO, then this cell will become inactive and populated with the ''Bottom surface area'' value. The user inputs this value in square feet.
+
**'''Bottom surface area (A<sub>B</sub>):''' This is the surface area at the bottom of the engineered media.  It represents the area where the engineered media changes to native soils. Units are in square feet
**'''Bottom surface area (A<sub>B</sub>):''' This is the surface area at the bottom of the [[Design criteria for bioretention#Materials specifications - filter media|engineered media]].  It represents the area where the engineered media changes to native soils.  The user inputs this value in square feet.  
+
**'''Overflow depth (D<sub>O</sub>):''' This is the maximum depth of ponded water within the BMP (i.e., vertical distance from the overflow elevation to the top of the soil or media). Units are in feet. The maximum allowable depth is 1.5 feet.
**'''Total media depth (D<sub>M</sub>):''' This is the depth of the engineered media between the media surface and the native soils.  The user inputs this value in feet.
+
**'''Total media depth (D<sub>M</sub>):''' This is the depth of the engineered media between the media surface and the native soils.  Units are in feet.
**'''Depth below underdrain (D<sub>U</sub>):''' This is the depth of the media between the underdrain invert and the native soils. If the response to ''Is the underdrain elevated above native soils?'' is set to NO, then this cell will become inactive and populated with a 0.  The user inputs this value in feet.
+
**'''Depth below underdrain (D<sub>U</sub>):''' This is the depth of the media between the underdrain invert and the native soils. If the response to ''"Is the underdrain elevated above native soils?"'' is set to NO, then this cell will become inactive and populated with a 0.  Units are in feet.
**'''Media field capacity minus wilting point (FC-WP):''' This is the amount of water between [http://stormwater.pca.state.mn.us/index.php/Glossary#F field capacity] and the permanent [http://stormwater.pca.state.mn.us/index.php/Glossary#W wilting point] stored in the media above the underdrain. This is water often considered to be available for uptake by plants. If multiple types of media are used in the BMP, this value should be an average of the media installed above the underdrain.  Values for field capacity and wilting point based on soil type can be found [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties here]. The user inputs this value in cubic feet of water per cubic feet of media. The recommended range for this value is 0.05 to 0.17.
+
**'''Media field capacity minus wilting point (FC-WP):''' This is the amount of water between [http://stormwater.pca.state.mn.us/index.php/Glossary#F field capacity] and the permanent [http://stormwater.pca.state.mn.us/index.php/Glossary#W wilting point] stored in the media above the underdrain. This is water often considered to be available for uptake by plants. If multiple types of media are used in the BMP, this value should be a weighted average of [[Soil water storage properties|the soil water storage values of the media ]] installed above the underdrain.  Values for field capacity and wilting point based on soil type can be found [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties here]. Units are in cubic feet of water per cubic feet of media. The recommended range for this value is 0.05 to 0.17.
**'''Media porosity minus filed capacity (n - FC)''' - This is the ratio of media pore space to the total media volume between the underdrain invert and the bottom of the media (top of native soil). If multiple types of media are used in the BMP, this value should be an average of the media installed between the underdrain and the native soils. Values for porosity and field capacity based on soil type can be found [[Soil water storage properties|here]]. The user inputs this value in cubic feet of pore space per cubic feet of media. The recommended range for this value is 0.15 to 0.35.
+
**'''Media porosity minus field capacity (n - FC)''' - This is the amount of water between [[Glossary#P|media porosity]] and [[Glossary#F|field capacity]] stored in the media between the underdrain invert and the bottom of the media (top of native soil). If multiple types of media are used in the BMP, this value should be a weighted average of [[Soil water storage properties|the soil water storage values of the media ]] installed between the underdrain and the native soils. Values for porosity and field capacity based on soil type can be found [[Soil water storage properties|here]]. Units are in cubic feet of pore space per cubic feet of media. The recommended range for this value is 0.15 to 0.35.
**'''Is a tree(s) planted in the BMP?:''' This is a YES/NO question.  If trees are planted within the bioretention basin then additional volume loss associated with evapotranspiration will be applied.
+
**'''Is a tree(s) planted in the BMP?:''' This is a YES/NO question.  If trees are planted within the biofiltration basin then additional volume loss associated with [[Glossary#E|evapotranspiration]] will be applied.
**'''Bioretention planting media mix:''' The user selects the type of media mix installed for planting from a predefined list of [[Design criteria for bioretention#Guidance for bioretention media composition|Media mixes]]: Media mix A (water quality blend), Media mix B (enhanced filtration blend), Media mix C (North Carolina State University water quality blend), Media mix D, or Other. This value is used to determine the annual phosphorus load reduction credit.
+
**'''Bioretention planting media mix:''' The user selects the type of media mix installed for planting from a predefined list of [[Design criteria for bioretention#Guidance for bioretention media composition|media mixes]]: Media mix A (water quality blend), Media mix B (enhanced filtration blend), Media mix C (North Carolina State University water quality blend), Media mix D, or Other. This value is used to determine the annual phosphorus load reduction credit.
 
**'''Is the P content of the media less than 30 mg/kg?:''' This is a YES/NO question.  The P content of the planting media should be tested using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3] test or an [[Design criteria for bioretention#Notes about soil phosphorus testing: applicability and interpretation|acceptable alternative method]]. Select YES if the P content of the planting media is less than 30 milligrams per kilogram and NO if it is greater.  P content testing is not needed for planting media C or D; therefore, this item will automatically populate to YES if one of those two media types are selected. This value is used to determine the annual phosphorus load reduction credit.
 
**'''Is the P content of the media less than 30 mg/kg?:''' This is a YES/NO question.  The P content of the planting media should be tested using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3] test or an [[Design criteria for bioretention#Notes about soil phosphorus testing: applicability and interpretation|acceptable alternative method]]. Select YES if the P content of the planting media is less than 30 milligrams per kilogram and NO if it is greater.  P content testing is not needed for planting media C or D; therefore, this item will automatically populate to YES if one of those two media types are selected. This value is used to determine the annual phosphorus load reduction credit.
**'''Is a soil amendment used to attenuate phosphorus?:''' This is a YES/NO question.  Answer YES if the bioretention filter media contains [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption soils amendments to enhance phosphorus sorption] and NO if amendments are not used. This value is used to determine the annual phosphorus load reduction credit.
+
**'''Do you have a properly designed phosphorus treatment layer or area in your system (e.g. iron enhanced layer)?:''' This is a YES/NO question.  Answer YES if the bioretention filter media contains [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption soil amendments to enhance phosphorus sorption] and NO if amendments are not used. This value is used to determine the annual phosphorus load reduction credit.
**'''Underlying soil - Hydrologic Soil Group:''' The user selects the most restrictive soil (lowest hydraulic conductivity) within 3 feet of the soil/media interface in the biofiltration basin. There are 14 soil options that fall into 4 different Hydrologic Soil Groups ([[Glossary#H|Hydrologic Soil Group]] (HSG) A, B, C, or D) for the user. Once a soil type is selected, the corresponding [[Design infiltration rates|infiltration rates]] will populate in the ''Infiltration rate of underlying soils'' field. The user may also select ''User Defined''.  This selection will activate the ''User Defined Infiltration Rate'' cell allowing the user to enter a different value from the values in the predefined selection list. The maximum allowable infiltration rate is 1.63 inches per hour.
+
**'''Underlying soil - Hydrologic Soil Group:''' The user selects the most restrictive soil (lowest hydraulic conductivity) within the 5 feet below the media/native soil interface of the biofiltration basin. There are 14 soil options that fall into 4 different Hydrologic Soil Groups ([[Glossary#H|Hydrologic Soil Group]] (HSG) A, B, C, or D) for the user. Once a soil type is selected, the corresponding [[Design infiltration rates|infiltration rate]] will populate the ''Infiltration rate of underlying soils'' field. The user may also select ''User Defined''.  This selection will activate the ''User Defined Infiltration Rate'' cell, allowing the user to enter a different value from those in the predefined selection list. The maximum allowable infiltration rate is 1.63 inches per hour.
**'''Required drawdown time:''' This is the time in which the stormwater captured by and ponded within the BMP must drain into the underlying soil/media. The user may select from predefined values of 48 or 24 hours. The [http://www.pca.state.mn.us/index.php/water/water-types-and-programs/stormwater/construction-stormwater/index.html MPCA Construction Stormwater General Permit] requires drawdown within 48 hours, but 24 hours is Highly Recommended when discharges are to a [[Sensitive waters and other receiving waters|trout stream]]. The calculator uses the underlying soil infiltration rate and the ''Depth below underdrain'' to check if the BMP is meeting the drawdown time requirement. The user will encounter an error and be required to enter a new ''Depth below underdrain'' if the stormwater stored in the BMP cannot drawdown in the required time.
+
**'''Required drawdown time:''' This is the time in which the stormwater captured by and ponded within the BMP must drain into the underlying soil and/or flow through the underdrain. The user must select from predefined values of 48 or 24 hours. The [http://www.pca.state.mn.us/index.php/water/water-types-and-programs/stormwater/construction-stormwater/index.html MPCA Construction Stormwater General Permit] requires drawdown within 48 hours, but 24 hours is ''Highly Recommended'' when discharges are to a [[Sensitive waters and other receiving waters|trout stream]]. The calculator uses the underlying soil infiltration rate and the ''Depth below underdrain (D<sub>U</sub>)'' to check if the BMP is meeting the drawdown time requirement. The user will encounter an error and be required to enter a new ''Depth below underdrain (D<sub>U</sub>)'' if the stormwater stored in the BMP cannot drawdown in the required time. Note that the upper limit of 1.5 feet set for the ''Overflow depth (D<sub>O</sub>)'' also serves to ensure that the required drawdown time is met.  
**'''BMP Summary Tab:''' The BMP Summary tab summarizes the volume and pollutant reductions provided by the specific BMP. It details the performance goal volume reductions and annual average volume, dissolved P, particulate P, and TSS load reductions. Included in the summary are the total volume and pollutant loads received by the BMP from its direct watershed, from upstream BMPs and a combined value of the two. Also included in the summary, are the volume and pollutant load reductions provided by the BMP, in addition to the volume and pollutant loads that exit the BMP through the outflow. This outflow load and volume is what is routed to the downstream BMP if one is defined in the ''Watershed'' tab. Finally, percent reductions are provided for the percent of the performance goal achieved, percent annual runoff volume retained, total percent annual particulate phosphorus reduction, total percent annual dissolved phosphorus reduction, total percent annual TP reduction, and total percent annual TSS reduction.
+
*'''BMP Summary tab:''' The BMP Summary tab summarizes the volume and pollutant reductions provided by the specific BMP. It details the performance goal volume reductions and annual average volume, dissolved P, particulate P, and TSS load reductions. Included in the summary are the total volume and pollutant loads received by the BMP from its direct watershed, from upstream BMPs and a combined value of the two. Also included in the summary are the volume and pollutant load reductions provided by the BMP, along with the volume and pollutant loads that exit the BMP through the outflow. This outflow load and volume is what is routed to the downstream BMP, if one is defined in the ''Watershed'' tab. Finally, percent reductions are provided for the percent of the performance goal achieved, percent annual runoff volume retained, total percent annual particulate phosphorus reduction, total percent annual dissolved phosphorus reduction, total percent annual TP reduction, and total percent annual TSS reduction.
  
 
==Model input requirements and recommendations==
 
==Model input requirements and recommendations==
The following are requirements or recommendations for inputs into the MIDS calculator. If the following are not met, an error message will inform the user to change the input to meet the requirement.
+
 
*Overflow depth cannot be greater than 1.5 feet
+
If the following requirements for inputs into the MIDS calculator are not met, then an error message will inform the user to change the input to meet the requirement.
*The water underneath the underdrain must meet the drawdown time requirement specified. The drawdown time requirement is checked by comparing the user defined drawdown time with the calculated drawdown time(DDT<sub>calc</sub>), given by
+
*''Overflow depth (D<sub>O</sub>)'' cannot be greater than 1.5 feet
 +
*Surface areas must be equal to or less than all surface areas at higher elevations
 +
*The ''Depth below underdrain (D<sub>U</sub>)'' cannot be greater than the ''Total media depth (D<sub>M</sub>)''
 +
*''Infiltration rate of underlying soils'' cannot exceed 1.63 inches per hour
 +
*If the user enters a value for ''field capacity minus wilting point (FC-WP)'' or ''porosity minus field capacity (n-FC)'' outside the recommended range a warning will appear.  The user will not be required to enter a new value.
 +
*The water below the underdrain must meet the user-specifed drawdown time requirement. The drawdown time requirement is checked by comparing the specified drawdown time with the calculated drawdown time (DDT<sub>calc</sub>), given by
  
 
<math>DDT_{calc}=D_U / (I_R / 12)</math>
 
<math>DDT_{calc}=D_U / (I_R / 12)</math>
  
 
Where
 
Where
:DU is the depth below the underdrain (ft); and
+
:D<sub>U</sub> is the depth below the underdrain (ft); and
:IR is the infiltration rate of the native soils (inches/hr).
+
:I<sub>R</sub> is the infiltration rate of the native soils (in/hr).
  
If DDT<sub>calc</sub> is greater than the user defined required drawdown time then the user will be prompted to enter a new depth below the underdrain or infiltration rate of the native soils.
+
If DDT<sub>calc</sub> is greater than the user-specified required drawdown time then the user will be prompted to enter a new depth below the underdrain or infiltration rate of the native soils.
*Infiltration rates of the underlying soils are restricted to a maximum of 1.63 inches/hour
 
*Surface areas must be equal to or less than all surface areas at higher elevations
 
*The ''Depth below the underdrain'' cannot be greater than the ''Total media depth''
 
*If the user enters a value for ''field capacity minus wilting point'' or ''porosity minus field capacity'' outside the recommended range a warning will appear.  The user will not be required to enter a new value.
 
  
 
==Methodology==
 
==Methodology==
  
===Required Treatment Volume===
+
===Required treatment volume===
''Required treatment volume'', or the volume of stormwater runoff delivered to the BMP, equals the performance goal (1.1 inches or user-specified performance goal) times the impervious area draining to the BMP plus any water routed to the BMP from an upstream BMP. This stormwater is delivered to the BMP instantaneously following the [http://www.stormh2o.com/SW/Articles/Kerplunk_15253.aspx Kerplunk method].
 
  
===Volume Reduction===
+
''Required treatment volume'', or the volume of stormwater runoff delivered to the BMP, equals the performance goal ([[Performance goals for new development, re-development and linear projects|1.1 inches for MIDS]] or user-specified performance goal) times the impervious area draining to the BMP plus any water routed to the BMP from an upstream BMP. This stormwater is delivered to the BMP instantaneously.
The volume reduction achieved by a BMP compares the capacity of the BMP to the required treatment volume. The ''Volume reduction capacity of BMP [V]'' is calculated using BMP inputs provided by the user. For this BMP, the volume reduction credit methodology is determined by the location of the underdrain.
 
  
====Underdrain located at BMP bottom====
+
===Volume reduction===
If the underdrain is located at the bottom of the BMP, then the ''Volume reduction capacity of BMP [V]'' is determined based on infiltration into the bottom of the BMP (V<sub>inf_b</sub>), infiltration into the side slopes of the BMP (V<sub>inf_s</sub>), and evapotranspiration in the planting media above the underdrain (V<sub>ET</sub>).
 
  
Even with an underdrain present, under saturated media conditions some water will infiltrate through the bottom soils as water in the basin draws down. The volume of water lost through the bottom (V<sub>inf_b</sub>) of the BMP equals the following
+
The total estimated ''Volume reduction capacity of BMP [V]'' is the sum of infiltration and ET occurring in the biofiltration BMP, and is calculated with user-provided inputs. For this BMP, the location of the underdrain determines how the infiltration component is calculated. If the underdrain is located at the bottom of the BMP, then the infiltration credit is based on infiltration into the bottom of the BMP (V<sub>inf<sub>b</sub></sub>) and into side slopes of the BMP above the underdrain (V<sub>inf<sub>s</sub></sub>). In contrast, if the underdrain is elevated above the bottom of the BMP, then the infiltration credit is based on the volume capacity of the bioretention base (V<sub>BB</sub>) between the underdrain and the native soils, and infiltration into the side slopes of the BMP above the underdrain (V<sub>inf<sub>s</sub></sub>). Both types of underdrain configurations can receive credit for ET in the media above the underdrain (V<sub>ET</sub>). A biofiltration system with an elevated underdrain thus behaves as a dual system, with the portion above the drain acting like a biofiltration system with an underdrain at the bottom and the portion below the underdrain acting like a bioinfiltration system.
  
<math>V_{Inf_B} = I_R * (DDT) * A_B / (12in/ft) = 0.06 * (DDT) * A_B / (12in/ft)</math>
+
The ''Volume of retention provided by BMP'' is the total instantaneous volume credit that can be claimed for that BMP, and is determined by [[Requirements, recommendations and information for using bioretention with an underdrain BMPs in the MIDS calculator#Comparison of volume reduction capacity with volume performance goal|comparing the ''Volume reduction capacity of BMP [V]'' to the ''Required treatment volume'']].
 +
 
 +
====Volume reduction from infiltration====
 +
 
 +
=====Underdrain located at bottom of engineered media: ''Volume reduction from basin bottom infiltration (V<sub>inf<sub>b</sub></sub>)''=====
 +
Even with an underdrain installed at the bottom of the engineered media, under saturated conditions some water will infiltrate through the bottom soils rather than pass through the underdrain.  This ''Volume reduction from basin bottom infiltration (V<sub>inf<sub>b</sub></sub>)'' is given by
 +
 
 +
<math>V_{Inf_b} = I_R * (DDT) * A_B / (12in/ft) = 0.06 * (DDT) * A_B / (12in/ft)</math>
  
 
Where
 
Where
 
:I<sub>R</sub> is an infiltration rate into the native soils of 0.06 inches per hour;
 
:I<sub>R</sub> is an infiltration rate into the native soils of 0.06 inches per hour;
:A<sub>B</sub> is the surface area at the bottom of the BMP in ft<sup>2</sup>; and
+
:A<sub>B</sub> is the surface area at the bottom of the BMP (ft<sup>2</sup>); and
:DDT is the drawdown time in hours.
+
:DDT is the drawdown time (hr).
  
 
The default infiltration rate is set at 0.06 inches per hour to represent a D soil. This rate was selected because it is assumed most of the stormwater will pass through the underdrain before it can infiltrate through the bottom of the BMP. This may be a conservative assumption if underdrains are small, spaced
 
The default infiltration rate is set at 0.06 inches per hour to represent a D soil. This rate was selected because it is assumed most of the stormwater will pass through the underdrain before it can infiltrate through the bottom of the BMP. This may be a conservative assumption if underdrains are small, spaced
far apart, and the underlying soil has an infiltration rate greater than 0.06 inches per hour. Conversely, more closely spaced or larger underdrains may allow the basin to drain in less than the required drawdown time, resulting in a slight overestimation of infiltration loss through the basin bottom.  If the user specifies that an impermeable liner is present at the bottom of the BMP, then no credit is given for infiltration into the bottom soils.
+
far apart, and the underlying soil has an infiltration rate greater than 0.06 inches per hour. Conversely, more closely spaced or larger underdrains may allow the basin to drain in less than the required drawdown time, resulting in a slight overestimation of (V<sub>inf<sub>b</sub></sub>).  If the user specifies that an impermeable liner is present at the bottom of the BMP, then no credit is given for infiltration into the bottom soils.
  
Under saturated conditions within the filter media, water will infiltrate through the sides of the basin as the stormwater draws down through the underdrain. Stormwater lost from a sloped sidewall (V<sub>inf_s</sub>) is considered to infiltrate vertically into the surrounding soil. The volume of water infiltrated through the sidewalls is given by
+
=====Elevated underdrain: ''Volume reduction stored below the underdrain''=====
  
<math>V_{InfS} = I_R * (DDT / 2) * (A_O - A_U ) / (12in/ft) = 0.06 * (DDT / 2) * (A_O - A_U ) / (12in/ft)</math>
+
If the underdrain is elevated above the bottom of the BMP, then storage capacity becomes available in the media between the underdrain and the native soils. 
 +
In systems with an elevated underdrain, this ''Volume reduction stored below underdrain'' is credited instead basin bottom infiltration (V<sub>Inf<sub>b</sub></sub>) credit that is given when the underdrain is at the bottom of the engineered media. This ''Volume reduction stored below underdrain'' (V<sub>U</sub>) is given by
 +
 
 +
<math>V_U= (A_U + A_B) / 2 * (n - FC) * D_U </math>
  
 
Where:
 
Where:
:A<sub>O</sub> is the surface area at overflow in ft<sup>2</sup>; and
+
:A<sub>U</sub> is the surface area at the underdrain (ft<sup>2</sup>);
:A<sub>U</sub> is the surface area at the underdrain in ft<sup>2</sup>  
+
:A<sub>B</sub> is the surface area at the bottom of the basin (ft<sup>2</sup>);
 +
:(n - FC) is the media porosity minus field capacity of the soils; and
 +
:D<sub>U</sub> is the depth of the media below the underdrain (ft).
 +
 
 +
The stored water must drain within the specified drawdown time. The underlying soil controls the infiltration rate. The user must input the soil with the most restrictive hydraulic conductivity in the 5 feet directly below the basin (i.e. below the bottom of the engineered media). If the user specifies that an impermeable liner is present at the bottom of the BMP, then no volume reduction credit is given for storage below the underdrain.
  
The drawdown time is reduced by a factor of 2 to account for the drop in water level within the BMP over the drawdown period. The drop in water level is therefore considered to be linear over the drawdown time. A conservative default infiltration rate of 0.06 inches per hour is used because it is assumed that most of the stormwater will pass through the underdrain before it can infiltrate through the side walls of the BMP.  If the user specifies that an impermeable liner is present on the sides of the BMP, then no credit is given for infiltration into the side soils.
+
=====Volume reduction from basin sides infiltration (V<sub>inf<sub>s</sub></sub>): underdrain elevated or at bottom of engineered media=====
  
The volume of water lost through evapotranspiration (VET) is the smaller of two calculated values, potential ET and measured ET.  
+
Under saturated conditions within the filter media, water will infiltrate through any existing sloped sidewalls of the basin as the stormwater draws down through the underdrain. Stormwater lost from a sloped sidewall (V<sub>inf<sub>s</sub></sub>) is considered to infiltrate vertically into the surrounding soil. This credit is calculated whether the underdrain is elevated or at the base of the engineered media. The volume of water infiltrated through the sidewalls is given by
 +
 
 +
<math>V_{Inf_s} = I_R * (DDT / 2) * (A_O - A_U ) / (12in/ft) = 0.06 * (DDT / 2) * (A_O - A_U ) / (12in/ft)</math>
 +
 
 +
Where:
 +
:A<sub>O</sub> is the surface area at overflow (ft<sup>2</sup>);
 +
:A<sub>U</sub> is the surface area at the underdrain (ft<sup>2</sup>); and
 +
:DDT is the drawdown time (hr).
 +
 
 +
Due to the fact that drawdown occurs as a continuous process, basin sides infiltration is not presumed to occur along the entire height of the sidewall during the entire drawdown time. For example, at "time zero", the entire sidewall should be exposed to saturated conditions and exhibit sidewall infiltration; but at the end of the drawdown period, there would theoretically be no section of the sidewall that is exposed to saturated conditions. Therefore, the drawdown time used in the calculation of (V<sub>inf<sub>s</sub></sub>) is reduced by a factor of 2 to account for the drop in water level and to approximate the "average" water level within the BMP during the drawdown period. The drop in water level is thus assumed to be linear over the drawdown time. A conservative default infiltration rate of 0.06 inches per hour is used because it is assumed that most of the stormwater will pass through the underdrain before it can infiltrate through the sidewalls of the BMP. If the user specifies that an impermeable liner is present on the sides of the BMP or if the sidewalls are not sloped (i.e., A<sub>O</sub> = A<sub>U</sub>), then no credit is given for infiltration into the side soils.
 +
 
 +
====Volume reduction from evapotranspiration (ET)====
 +
 
 +
In addition to the credit given for infiltration, a biofiltration BMP can achieve volume reduction through ET. The volume of water lost through evapotranspiration (V<sub>ET</sub>) is the smaller of two calculated values, potential ET and measured ET.  
 
 
*Potential ET (ET<sub>pot</sub>) is equal to the amount of water stored between [[Glossary#F|field capacity]] and the [[Glossary#W|wilting point]] in the media above the underdrain.  ET<sub>pot</sub> is given by
+
=====Potential ET (ET<sub>pot</sub>)=====
 +
 
 +
Potential ET (ET<sub>pot</sub>) is equal to the amount of water stored between [[Glossary#F|field capacity]] and the [[Glossary#W|wilting point]] in the media above the underdrain, and is given by
  
 
<math>ET_{pot} = (D_M - D_U ) * (A_M + A_U) / 2 * (FC - WP)</math>
 
<math>ET_{pot} = (D_M - D_U ) * (A_M + A_U) / 2 * (FC - WP)</math>
  
 
Where
 
Where
:D<sub>M</sub> is the total media depth in feet;
+
:D<sub>M</sub> is the total media depth (ft);
:D<sub>U</sub> is the depth under the underdrain in feet;
+
:D<sub>U</sub> is the depth under the underdrain (ft);
:A<sub>M</sub> is the surface area of the media in square feet;
+
:A<sub>M</sub> is the surface area of the media (ft<sup>2</sup>);
:AU is the surface area at the underdrain in square feet; and
+
:AU is the surface area at the underdrain (ft<sup>2</sup>); and
 
:(FC – WP) is the difference between field capacity and wilting point.
 
:(FC – WP) is the difference between field capacity and wilting point.
  
*Measured ET (ET<sub>mea</sub>) is the amount of water lost to ET as measured using available data. Pan evaporation (PE) measurements collected at the University of Minnesota Southwest Experiment Station at Lamberton, Minnesota were used to estimate an average daily PE (Source: [http://conservancy.umn.edu/handle/109293 Climate of Minnesota Part XII- The Hydrologic Cycle and Soil Water], 1979). A rate of 0.2 inches per day was used, which is an intermediate value between the summertime maximum rate and the lowest rates in October. PE is converted to ET by multiplying by a correction factor of 0.5. Analysis of rainfall patterns indicates that a typical time period between precipitation events is 72 hours in Minnesota. Therefore, a volume loss from ET is calculated over a 3 day period to measure conformance to the MIDS performance goal. Therefore, the measured ET volume equals the media surface area (A<sub>M</sub>) in square feet times the daily ET rate in inches per day times 3 days.  
+
=====Measured ET (ET<sub>mea</sub>)=====
 +
 
 +
Measured ET (ET<sub>mea</sub>) is the amount of water lost to ET as measured using available data. An average daily pan evaporation rate was estimated using previous measurements collected at the University of Minnesota Southwest Experiment Station at Lamberton, Minnesota (Source: [https://conservancy.umn.edu/handle/11299/109293 Climate of Minnesota Part XII- The Hydrologic Cycle and Soil Water], 1979). A rate of 0.2 inches per day was selected, as this is an intermediate value between the summertime maximum rate and the lowest rates in October. Analysis of rainfall data indicates that a typical time period between precipitation events is 72 hours (3 days) in Minnesota. Therefore, a 3 day period is used to calculate the ET<sub>mea</sub>. A factor of 0.5 is also applied to convert the pan evaporation rate to ET<sub>mea</sub>. The ET<sub>mea</sub> volume thus equals the media surface area (A<sub>M</sub>) in square feet times the average daily ET rate in inches per day times 3 days.  
  
 
<math>ET_{mea} = A_M * 0.2 in/day * 0.5 * 3 days / 12 in/ft  =  0.025 A_M</math>
 
<math>ET_{mea} = A_M * 0.2 in/day * 0.5 * 3 days / 12 in/ft  =  0.025 A_M</math>
Line 106: Line 143:
 
:If trees are planted in the bioretention basin then ET<sub>mea</sub> is multiplied by a factor of 3.
 
:If trees are planted in the bioretention basin then ET<sub>mea</sub> is multiplied by a factor of 3.
  
Measured ET and potential ET are compared and the volume lost to ET is the smaller of the two values.
+
====Comparison of volume reduction capacity with volume performance goal====
  
====Elevated Underdrain====
+
The sum of the volumes lost to infiltration and to ET as calculated using the appropriate methods above gives the ''Volume reduction capacity of BMP [V]''. The MIDS calculator compares the ''Volume reduction capacity of BMP [V]'' with the ''Required treatment volume'', and the lesser of the two values is used to populate the ''Volume of retention provided by BMP''. This comparison between potential and actual treatment volumes ensures that the BMP does not claim more credit than is due based on the actual amount of water routed to it. The ''Volume of retention provided by BMP'' is the actual volume credit the BMP receives toward the instantaneous performance goal. For example, if the BMP is oversized the user will only receive volume credit for the ''Required treatment volume'' routed to the BMP.
If the underdrain is elevated above the bottom of the BMP, then the volume reduction credit is determined based on the storage capacity in the media between the underdrain and the native soils, infiltration through the sides of the BMP (V<sub>inf_s</sub>), and evapotranspiration in the planting media above the underdrain (V<sub>ET</sub>).
 
  
When the underdrain is elevated, storage capacity becomes available in the media between the underdrain and the native soils.  The storage capacity credit replaces the credit given for infiltration into the bottom of the BMP below the underdrain (V<sub>Inf_B</sub>). The volume of water captured below the underdrain is given by
+
Annual volume retention is assessed by converting the instantaneous ''Volume reduction capacity of BMP [V]'' to an annual volume reduction percentage. This is accomplished through the use of [[Performance curves for MIDS calculator|performance curves]] developed from a range of modeling scenarios. These performance curves use the ''Volume reduction capacity of BMP [V]'', the [[Design infiltration rates|infiltration rate]] of the underlying soils, the percent imperviousness of the contributing watershed area, and the size of the contributing watershed to calculate the ''Percent annual runoff volume retained'' and annual ''Retention volume provided by BMP''.
  
<math>V= (A_U + A_B) / 2 * (n - FC) * D_U </math>
+
{{:Soil water storage properties}}
  
Where:
+
===Pollutant reduction===
:A<sub>U</sub> is the surface area at the underdrain in ft<sup>2</sup>;
+
[[File:schematic showing pollutant reduction calculations bioretention with underdrain.jpg|300px|thumb|alt=Schematic showing pollutant load reductions for infiltrated and filtration in Bioretention basin (with an underdrain)|<font size=3>Schematic showing how pollutant load reductions are calculated for Bioretention basin (with an underdrain).  All TSS and phosphorus in infiltrated water is considered reduced.  TSS loads are reduced by 60 percent for the portion of water filtered and captured by the underdrain.  Phosphorus reductions in the filtered water are a function of the [[Phosphorus credits for bioretention systems with an underdrain|media and media thickness]].</font size>]]
:A<sub>B</sub> is the surface area at the bottom of the basin in ft<sup>2</sup>;
 
:(n - FC) is the media porosity minus field capacity of the soils; and
 
:D<sub>U</sub> is the depth of the media below the underdrain in ft
 
  
The stored water must drain within the specified drawdown time. The underlying soil controls the infiltration rate. The user must input the soil with the most restrictive hydraulic conductivity in the 3 feet directly below the basin.
+
Pollutant removal can be accomplished both via volume reducing and non-volume reducing processes in a biofiltration BMP. Pollutant load reductions are calculated on an annual basis and are thus dependent upon the volume of water retained by the BMP through infiltration and ET and the volume of water treated by filtration in the BMP.
  
In addition to the credit given for the storage capacity below the underdrain, a biofiltration system with an elevated underdrain also receives volume reduction credit for infiltration into the sloped sidewall as well as evapotranspiration. Credit is given following the same methods described when the underdrain is located at the bottom of the BMP (see discussion above). A biofiltration system with an elevated underdrain thus behaves as a dual system, with the portion above the drain acting like a biofiltration system with an underdrain at the bottom and the portion below the underdrain acting like a bioinfiltration system.
+
====Pollutant reduction via volume reduction====
 +
The first step in calculating annual pollutant load reductions is to determine the annual ''Retention volume provided by BMP'' as discussed in the [[Requirements,_recommendations_and_information_for_using_bioretention_with_an_underdrain_BMPs_in_the_MIDS_calculator#Volume reduction|Volume reduction section]]. All pollutants in this retained water are considered captured for a 100 percent removal. Thus, while oversizing a BMP above the ''Required treatment volume'' will not provide additional credit towards the instantaneous volume performance goal, it may provide additional annual pollutant reduction through treatment of water beyond the ''Required treatment volume''.
  
The ''Volume of retention provided by BMP'' is the amount of volume credit the BMP provides toward the performance goal.  This value is equal to the ''Volume reduction capacity of BMP [V]'', calculated using the above method, as long as the volume reduction capacity is less than or equal to the ''Required treatment volume''.  If ''Volume reduction capacity of BMP [V]'' is greater than ''Required treatment volume'', then the BMP volume credit is equal to ''Required treatment volume''.  This check makes sure the BMP is not getting more credit than the amount of water it receives.  For example, if the BMP is oversized the user will only receive credit for ''Required treatment volume'' routed to the BMP.
+
====Pollutant reduction via non-volume reduction treatment====
 +
Stormwater that is routed to the BMP but not infiltrated or lost through ET is assumed to flow through the filter media and out the underdrain, and is indicated by the ''Annual outflow volume'' in the BMP Summary tab. The removal rate for TSS in this filtered stormwater is set at 60 percent.
  
===Pollutant Reduction===
+
{{alert|The Minnesota Stormwater Manual provides a TSS credit of 80 percent for biofiltration practices. A literature review suggests 80 percent may be high, but the Construction Stormwater (CSW) General Permit requires 80 percent reduction of TSS for filtration practices. Therefore, the CSW permit target cannot be achieved using the MIDS calculator. We created a MIDS calculator Excel file that utilizes 80 percent removal for biofiltration practices. Access the file at [[file:Corrected July 14.xls]].|alert-info}}
[[File:schematic showing pollutant reduction calculations bioretention with underdrain.jpg|300px|thumb|alt=Schematic showing pollutant load reductions for infiltrated and filtration|<font size=3>Schematic showing how pollutant load reductions are calculated for bioretention with an underdrain. All TSS and phosphorus in infiltrated water is reduced. TSS loads are reduced by 60 percent for the portion captured by the underdrain. Phosphorus reductions are a function of the [[Phosphorus credits for bioretention systems with an underdrain|media and media thickness]].</font size>]]
 
  
Pollutant load reductions are calculated on an annual basis.  Therefore, the first step in calculating annual pollutant load reductions is converting ''Volume reduction capacity of BMP'', which is an instantaneous volume reduction, to an annual volume reduction percentage. This is accomplished through the use of [[Performance curves for MIDS calculator|performance curves]] developed from multiple modeling scenarios. The performance curves use ''Volume reduction capacity of BMP [V]'', the [[Design infiltration rates|infiltration rate]] of the underlying soils, the contributing watershed percent impervious area, and the size of the contributing watershed to calculate a percent annual volume reduction. While oversizing a BMP above ''Required treatment volume'' will not provide additional credit towards the performance goal volume, it may provide additional pollutant reduction.
+
The removal rates for particulate phosphorus and dissolved phosphorus in the filtered stormwater depend on the user's input to three drop-down boxes: “Planting media mix”; “Is the P content of the media less than 30 mg/kg?”; and “Is a soil amendment used to attenuate phosphorus?”.
  
A 100 percent removal is credited for all pollutants associated with the reduced volume of stormwater. Stormwater captured by the bioretention system but not infiltrated or consumed through ET is assumed to flow through the filter media and out the underdrain.  A constant 60 percent removal rate is applied to the filtered stormwater for TSS reduction.  The removal rates of the filtered stormwater for annual particulate phosphorus and dissolved phosphorus depend on the answers given to the three user inputs: ''Bioretention planting media mix'', ''Is the P content of the media less than 30 mg/kg?'' and ''Is a soil amendment used to attenuate phosphorus?''
+
=====Particulate Phosphorus=====
 +
The [[Phosphorus credits for bioretention systems with an underdrain| particulate phosphorus credit]] given for non-volume reduction treatment is either 0 percent or 80 percent depending on the media mix used and its P content.
  
'''Particulate Phosphorus:''' The particulate [[Phosphorus credits for bioretention systems with an underdrain|phosphorus credit]] given is either 0 percent or 45 percent depending on the media mix used and the P content of the media.
+
*If [http://stormwater.pca.state.mn.us/index.php/Construction_specifications_for_bioretention#Materials_specifications_-_filter_media Media Mix] C or D is used, or if a media mix other than C or D is used and the soil phosphorus as measured using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test]  or a [[Design_criteria_for_bioretention#Notes_about_soil_phosphorus_testing:_applicability_and_interpretation|suitable alternative test]] is 30 milligrams per kilogram or less, then the annual particulate phosphorus reduction credit is 80 percent of the filtered water volume.
 +
*If a media mix other than C or D is used and the soil phosphorus has not been determined or is greater than 30 milligrams per kilogram as measured using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test] or a [[Design_criteria_for_bioretention#Notes_about_soil_phosphorus_testing:_applicability_and_interpretation|suitable alternative test]], then the annual particulate phosphorus reduction credit is 0 percent of the filtered water volume.  
  
*If [[Phosphorus credits for bioretention systems with an underdrain|Media Mix]] C or D is used, the annual particulate phosphorus reduction credit is 45 percent of the filtered water volume.
+
NOTE: If the Olsen test is used to determine P content of the media mix, a [[Design_criteria_for_bioretention#Notes_about_soil_phosphorus_testing:_applicability_and_interpretation| simple conversion]] is required.
*If a media mix other than C or D is used and the soil phosphorus as measured using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test]  or a suitable alternative test is 30 milligrams per kilogram or less, the annual particulate phosphorus reduction credit is 45 percent of the filtered water volume.
 
**If a media mix other than C or D is used and the soil phosphorus as measured using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test] or a suitable alternative test is greater than 30 milligrams per kilogram, the annual pollutant phosphorus reduction credit is 0 percent of the filtered water volume.
 
**If a media mix other than C or D is used and the soil phosphorus has not been determined, the annual particulate phosphorus credit is 0 percent of the filtered water volume.  
 
  
'''Dissolved Phosphorus:''' The dissolved phosphorus credit given is between 0 percent and 60 percent depending on the media mix, the media P content, and if the media was amended to attenuate phosphorus.  
+
=====Dissolved Phosphorus=====
 +
The dissolved phosphorus credit given for non-volume reduction treatment is between 0 percent and 60 percent depending on the media mix, the media P content, and if the media was amended to attenuate phosphorus.  
  
*If Media Mix C or D is used, or if a media mix other than C or D is used and soil phosphorus as measured using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test] or a suitable alternative test is 30 milligrams per kilogram or less, the annual dissolved phosphorus credit applied to the filtered water volume is calculated by
+
*If Media Mix C or D is used, or if a media mix other than C or D is used and soil phosphorus as measured by the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test] or a [[Design_criteria_for_bioretention#Notes_about_soil_phosphorus_testing:_applicability_and_interpretation|suitable alternative test]] is 30 milligrams per kilogram or less, then the annual dissolved phosphorus credit applied to the filtered water volume, expressed as a percent, is given by
  
 
<math>credit = 20 percent (D_M- D_U) / 2 ft</math>
 
<math>credit = 20 percent (D_M- D_U) / 2 ft</math>
  
 
Where
 
Where
:D<sub>M</sub> - D<sub>U</sub> represents the media depth above the underdrain.
+
:D<sub>M</sub> - D<sub>U</sub> represents the media depth above the underdrain (ft).
  
 
The credit is calculated as a percent reduction with a maximum value of 20 percent for media depths above the underdrain greater than 2 feet.  If the media depth above the underdrain is less than 2 feet the credit is reduced equivalently.   
 
The credit is calculated as a percent reduction with a maximum value of 20 percent for media depths above the underdrain greater than 2 feet.  If the media depth above the underdrain is less than 2 feet the credit is reduced equivalently.   
*If a media mix other than C or D is used and the soil phosphorus as measured using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test] or a suitable alternative test is greater than 30 milligrams per kilogram, the annual dissolved phosphorus credit is 0 percent of the filtered water volume.
+
*If a media mix other than C or D is used and the soil phosphorus has not been determined or is greater than 30 milligrams per kilogram as measured using the [http://soiltesting.tamu.edu/files/mehlich3.pdf Mehlich 3 test] or a [[Design_criteria_for_bioretention#Notes_about_soil_phosphorus_testing:_applicability_and_interpretation|suitable alternative test]], then the annual dissolved phosphorus credit is 0 percent of the filtered water volume.
*If a media mix other than C or D is used and the soil phosphorus has not been determined, the annual dissolved phosphorus credit is 0 percent of the filtered water volume.  
 
 
*An additional annual dissolved phosphorus credit of 40 percent of the filtered water volume may be received if [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption phosphorus-sorbing amendments] are used. Acceptable amendments include the following:  
 
*An additional annual dissolved phosphorus credit of 40 percent of the filtered water volume may be received if [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption phosphorus-sorbing amendments] are used. Acceptable amendments include the following:  
 
**5 percent by volume elemental iron filings above the internal water storage (IWS) layer or elevated underdrain;
 
**5 percent by volume elemental iron filings above the internal water storage (IWS) layer or elevated underdrain;
 
**minimum 5 percent by volume sorptive media above IWS layer or elevated underdrain;
 
**minimum 5 percent by volume sorptive media above IWS layer or elevated underdrain;
 
**minimum 5 percent by weight water treatment residuals (WTR) to a depth of at least 3.9 inches (10 centimeters);  
 
**minimum 5 percent by weight water treatment residuals (WTR) to a depth of at least 3.9 inches (10 centimeters);  
*An additional annual dissolved phosphorus credit commensurate with the research results can be applied if other phosphorus-sorptive amendments are proposed that have supporting third party research results showing dissolved phosphorus reduction for at least a 20-year lifespan.  
+
*For other proposed phosphorus-sorbing amendments: an additional annual dissolved phosphorus credit can be applied if and only if there is <u>supporting third party research</u> showing that this dissolved phosphorus reduction will occur for at least a 20-year lifespan.  The credit may be commensurate with existing research results, with the understanding that the user may be asked to provide this documentation.
  
 
{{:Phosphorus credits for bioretention systems with an underdrain}}
 
{{:Phosphorus credits for bioretention systems with an underdrain}}
Line 164: Line 197:
  
 
==Routing==
 
==Routing==
A biofiltration basin can be routed to any other BMP, except for a green roof and a swale side slope or any BMP that would cause stormwater to be rerouted back to the biofiltration basin already in the sequence.  All BMPs can be routed to a biofiltration, except for a swale side slope BMP.   
+
A biofiltration basin can be routed to any other BMP, except for a [[Green roofs|green roof]], a [[Filtration|swale]] side slope, or any BMP that would cause stormwater to be rerouted back to the biofiltration basin already in the sequence.  All BMPs can be routed to a biofiltration, except for a swale side slope BMP.   
  
 
==Assumptions for biofiltration basin with underdrain==
 
==Assumptions for biofiltration basin with underdrain==
 
The following general assumptions apply in calculating the credit for a biofiltration basin.  If these assumptions are not followed the volume and pollutant reduction credits cannot be applied.
 
The following general assumptions apply in calculating the credit for a biofiltration basin.  If these assumptions are not followed the volume and pollutant reduction credits cannot be applied.
*The biofiltration basin has been properly [[Design criteria for bioretention|designed]], [[Construction specifications for bioretention|constructed]] and will be properly [[Operation and maintenance of bioretention|maintained]].
+
*The biofiltration basin has been properly [[Design criteria for bioretention|designed]], [[Construction specifications for bioretention|constructed]], and will be properly [[Operation and maintenance of bioretention|maintained]].
 
*Stormwater runoff entering the biofiltration basin has undergone [[Pre-treatment|pretreatment]].
 
*Stormwater runoff entering the biofiltration basin has undergone [[Pre-treatment|pretreatment]].
 
*Stormwater captured by the BMP enters the BMP media instantaneously. This will slightly underestimate actual infiltration since some water will infiltrate through the basin bottom and sidewalls during a rain event, thus creating more volume for storage in the BMP.  
 
*Stormwater captured by the BMP enters the BMP media instantaneously. This will slightly underestimate actual infiltration since some water will infiltrate through the basin bottom and sidewalls during a rain event, thus creating more volume for storage in the BMP.  
Line 174: Line 207:
 
*Evapotranspiration is independent of plant type, plant density and weather conditions.
 
*Evapotranspiration is independent of plant type, plant density and weather conditions.
  
==Biofiltration Basin with an elevated underdrain example (Version 2)==
+
==Biofiltration Basin with an elevated underdrain example==
 
[[File:Schematic for example bioretention with underdrain.jpg|thumb|left|alt=schematic used for the MIDS calculator example bioretention with underdrain|<font size=3>Schematic for the MIDS calculator example for bioretention with an underdrain.  Impervious surface area is 1.4 acres.  Pervious surface area, which includes a turf area and the bioretention basin, is 0.8 acres.  See Step 1.</font size>]]
 
[[File:Schematic for example bioretention with underdrain.jpg|thumb|left|alt=schematic used for the MIDS calculator example bioretention with underdrain|<font size=3>Schematic for the MIDS calculator example for bioretention with an underdrain.  Impervious surface area is 1.4 acres.  Pervious surface area, which includes a turf area and the bioretention basin, is 0.8 acres.  See Step 1.</font size>]]
[[File:Tree trench no drain example site information tab.png|300px|thumb|alt=screen shot site information tab with elevated underdrain|<font size=3>Screen shot of site information tab for bioretention with elevated underdrain example. The User must input impervious acres and zip code. Other fields are optional. See Step 2.</font size>]]
+
[[File:Tree trench no drain example site information tab.png|300px|thumb|alt=screen shot Site Information tab with elevated underdrain|<font size=3>Screen shot of Site Information tab for bioretention with elevated underdrain example. The user must input impervious acres and ZIP code. Other fields are optional. See Step 2.</font size>]]
[[File:Schematic for example bioretention with elevated underdrain.jpg|300px|thumb|left|alt=Schematic used for example bioretention with elevated underdrain|<font size=3>Schematic used for example bioretention with elevated underdrain. See Step 1.</font size>]]
+
[[File:Schematic for example bioretention with elevated underdrain.jpg|300px|thumb|left|alt=Schematic used for example bioretention with elevated underdrain|<font size=3>Schematic used for MIDS calculator example for bioretention with elevated underdrain. See Step 1.</font size>]]
[[File:Schematic tab bioretention with elevated underdrain example.png|300px|thumb|alt=Screen shot of schematic tab for bioretention with elevated underdrain example|<font size=3>Screen shot of the Schematic tab for the bioretention with elevated underdrain example.  See Step 3.</font size>]]
+
[[File:Schematic tab bioretention with elevated underdrain example.png|300px|thumb|alt=Screen shot of Schematic tab for bioretention with elevated underdrain example|<font size=3>Screen shot of the MIDS calculator Schematic tab for the bioretention with elevated underdrain example.  See Step 3.</font size>]]
 +
 
 +
This example was completed using Version 2 of the Calculator.
  
 
An unlined biofiltration basin with an elevated underdrain is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area (turf area and the bioretention BMP area). All of the runoff from the watershed will be treated by the biofiltration basin. The soils across the area have a unified soils [http://stormwater.pca.state.mn.us/index.php/Design_infiltration_rates classification of SM] (HSG type B soil). The surface overflow is located 1 ft above the media surface.  The surface area of the biofiltration basin at the overflow point will be 6534 square feet.  The area is 5600 square feet at the media surface.  The surface area at the invert of the underdrain will be 3948 square feet. The area at the media-soil interface is 3320 square feet. The total media depth will be 3 feet with 1 foot of media between the underdrain and the native soils.  Following the MPCA [http://www.pca.state.mn.us/index.php/water/water-types-and-programs/stormwater/construction-stormwater/index.html Construction Stormwater General Permit] requirement, the water below the underdrain in the biofiltration basin needs to drawdown in a 48 hour time period. The media will be [[Design criteria for bioretention#Guidance for bioretention media composition|Media Mix C]], which is mostly sand resulting in a difference between the media [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties wilting point and field capacity] of 0.11 cubic feet per cubic foot and a difference between the [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties media porosity and field capacity] of 0.26 cubic feet per cubic foot. The P content of the media is less than 30 mg/kg (milligrams per kilogram) and no [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption soil amendments] will be used to attenuate phosphorus. The following steps detail how this system would be set up in the MIDS calculator.
 
An unlined biofiltration basin with an elevated underdrain is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area (turf area and the bioretention BMP area). All of the runoff from the watershed will be treated by the biofiltration basin. The soils across the area have a unified soils [http://stormwater.pca.state.mn.us/index.php/Design_infiltration_rates classification of SM] (HSG type B soil). The surface overflow is located 1 ft above the media surface.  The surface area of the biofiltration basin at the overflow point will be 6534 square feet.  The area is 5600 square feet at the media surface.  The surface area at the invert of the underdrain will be 3948 square feet. The area at the media-soil interface is 3320 square feet. The total media depth will be 3 feet with 1 foot of media between the underdrain and the native soils.  Following the MPCA [http://www.pca.state.mn.us/index.php/water/water-types-and-programs/stormwater/construction-stormwater/index.html Construction Stormwater General Permit] requirement, the water below the underdrain in the biofiltration basin needs to drawdown in a 48 hour time period. The media will be [[Design criteria for bioretention#Guidance for bioretention media composition|Media Mix C]], which is mostly sand resulting in a difference between the media [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties wilting point and field capacity] of 0.11 cubic feet per cubic foot and a difference between the [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties media porosity and field capacity] of 0.26 cubic feet per cubic foot. The P content of the media is less than 30 mg/kg (milligrams per kilogram) and no [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption soil amendments] will be used to attenuate phosphorus. The following steps detail how this system would be set up in the MIDS calculator.
Line 184: Line 219:
 
Step 1: Determine the watershed characteristics of your entire site.  For this example we have a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious area in type B soils.  The pervious area includes the turf area and the area of the biofiltration basin.   
 
Step 1: Determine the watershed characteristics of your entire site.  For this example we have a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious area in type B soils.  The pervious area includes the turf area and the area of the biofiltration basin.   
  
Step 2: Fill in the site specific information into the ''Site Information'' tab.  This includes entering a Zip Code (55414 for this example) and the watershed information from Step 1. The Managed turf area includes the turf area and the area of the bioretention basin.  Zip code and impervious area must be filled in or an error message will be generated.  Other fields on this screen are optional.
+
Step 2: Fill in the site specific information into the ''Site Information'' tab.  This includes entering a ZIP Code (55414 for this example) and the watershed information from Step 1. The Managed turf area includes the turf area and the area of the bioretention basin.  ZIP code and impervious area must be filled in or an error message will be generated.  Other fields on this screen are optional.
  
Step 3: Go to the Schematic tab and drag and drop the ''Bioretention basin (with underdrain)'' icon into the ''Schematic Window''
+
Step 3: Go to the Schematic tab and drag and drop the ''Bioretention basin (with underdrain)'' icon into the ''Schematic'' window.
  
Step 4: Open the BMP properties for the bioretention basin by right clicking on the ''Bioretention basin (with underdrain)'' icon and selecting ''Edit BMP properties'', or by double clicking on the ''Bioretention basin (with underdrain)'' icon.  
+
Step 4: Open the BMP properties for the bioretention basin by right clicking on the ''Bioretention basin (with underdrain)'' icon and selecting ''Edit BMP Properties'', or by double clicking on the ''Bioretention basin (with underdrain)'' icon.  
  
Step 5: If help is needed click on the ''Minnesota Stormwater Manual Wiki'' link or the ''Help'' button to review input parameter specifications and calculation specific to the ''Bioretention basin (with underdrain)'' BMP.
+
Step 5: If help is needed click on the ''Minnesota Stormwater Manual Wiki'' link or the ''Help'' button to review input parameter specifications and calculations specific to the ''Bioretention basin (with underdrain)'' BMP.
  
Step 6: Determine the watershed characteristics for the Bioretention basin.  For this example the entire site is draining to the bioretention basin.  The watershed parameters therefore include a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. There is no routing for this BMP. Fill in the BMP specific watershed information (1.4 acres on impervious cover and 0.8 acres of Managed turf in B soils).
+
Step 6: Determine the watershed characteristics for the Bioretention basin.  For this example the entire site is draining to the bioretention basin.  The watershed parameters therefore include a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. There is no routing for this BMP. Fill in the BMP specific watershed information in the ''Watershed'' tab (1.4 acres on impervious cover and 0.8 acres of Managed turf in B soils).
  
 
<gallery caption="MIDS calculator screen shots for inputs for bioretention with an elevated underdrain. Click on an image for enlarged view." widths="140px">
 
<gallery caption="MIDS calculator screen shots for inputs for bioretention with an elevated underdrain. Click on an image for enlarged view." widths="140px">
File:Watershed tab bioretention with elevated underdrain example.png|alt=Schematic showing watershed tab for bioretention elevated underdrain|Screen shot showing watershed tab for bioretention with an elevated underdrain. See Step 6.
+
File:Watershed tab bioretention with elevated underdrain example.png|alt=Schematic showing Watershed tab for bioretention elevated underdrain|Screen shot showing Watershed tab for bioretention with an elevated underdrain. See Step 6.
File:BMP Parameters tab bioretention with elevated underdrain example 1.png|alt=Schematic showing BMP Parameters tab for bioretention elevated underdrain|Screen shot showing BMP Parameters tab for bioretention with an elevated underdrain. See Step 7.
+
File:BMP Parameters tab bioretention with elevated underdrain example 1.png|alt=Schematic showing BMP Parameters tab for bioretention elevated underdrain|Screen shot showing BMP Parameters tab for bioretention with an elevated underdrain. See Step 7.
File:BMP Parameters tab bioretention with elevated underdrain example 2.png|alt=Schematic showing BMP Parameters tab for bioretention elevated underdrain|Screen shot showing BMP Parameters tab for bioretention with an elevated underdrain. See Step 7.
+
File:BMP Parameters tab bioretention with elevated underdrain example 3.png|alt=Schematic showing BMP Parameters tab for bioretention elevated underdrain|Screen shot showing BMP Parameters tab for bioretention with an elevated underdrain. See Step 7.
 
File:BMP Summary tab bioretention with elevated underdrain example.png|alt=screen shot BMP Summary tab for bioretention elevated underdrain|Screen shot of the BMP Summary tab for bioretention with an elevated underdrain. See Step 8.
 
File:BMP Summary tab bioretention with elevated underdrain example.png|alt=screen shot BMP Summary tab for bioretention elevated underdrain|Screen shot of the BMP Summary tab for bioretention with an elevated underdrain. See Step 8.
File:results tab bioretention with elevated underdrain example.png|alt=Screen shot results tab for bioretention with an elevated underdrain example|Screen shot for the example of a bioretention system with an elevated underdrain. See Step 10.
+
File:results tab bioretention with elevated underdrain example.png|alt=Screen shot of the Results tab for bioretention with an elevated underdrain example|Screen shot of Results tab for the example of a bioretention system with an elevated underdrain. See Step 10.
 
</gallery>
 
</gallery>
  
Step 7: Enter in the BMP design parameters into the ''BMP parameters'' tab.  Bioretention basin with an underdrain requires the following entries.
+
Step 7: Enter the BMP design parameters into the ''BMP parameters'' tab.  This bioretention basin with an elevated underdrain example would require the following entries:
 
*Is the underdrain elevated above native soils – Yes;
 
*Is the underdrain elevated above native soils – Yes;
 
*Are the sides of the basin lined with an impermeable liner – No;
 
*Are the sides of the basin lined with an impermeable liner – No;
 
*Is the bottom of the basin lined with an impermeable liner – No;
 
*Is the bottom of the basin lined with an impermeable liner – No;
*Surface area of overflow which is 6534 square feet;
+
*Surface area at overflow [A<sub>O</sub>]: 6534 square feet;
*Surface area at media surface which is 5600 square feet;
+
*Media surface area [A<sub>M</sub>]: 5600 square feet;
*Surface area at underdrain which is 3948 square feet;
+
*Surface area at underdrain [A<sub>U</sub>]: 3948 square feet;
*Bottom surface area (area at media-soil interface) which is 3230 square feet;
+
*Bottom surface area (area at media-soil interface) [A<sub>B</sub>]: 3230 square feet;
*Overflow depth which is 1 foot;
+
*Overflow depth [D<sub>O</sub>]: 1 foot;
*Total media depth which is 3 feet;
+
*Total media depth [D<sub>M</sub>]: 3 feet;
*Depth below underdrain which is 1 foot;
+
*Depth below underdrain [D<sub>U</sub>]: 1 foot;
*Media field capacity minus wilting point which is 0.11 cubic feet per cubic foot;
+
*Media field capacity minus wilting point [FP-WP]: 0.11 cubic feet per cubic foot;
*Media porosity minus field capacity which is 0.26 cubic feet per cubic foot;
+
*Media porosity minus field capacity [n-FC]: 0.26 cubic feet per cubic foot;
 
*Is a tree(s) planted in the BMP – No;
 
*Is a tree(s) planted in the BMP – No;
*Bioretention planting media mix which is Media Mix C;
+
*Bioretention planting media mix Media Mix C (selected in dropdown box);
*Is the P content of the media less than 30 mg/kg which autofills to “Yes” for Media Mix C;
+
*Is the P content of the media less than 30 mg/kg autofills to “Yes” for Media Mix C;
*Is a soil amendment used – No;
+
*Is there a designed phosphorus treatment layer – No;
*Underlying soil – Hydrologic Soil Group which is SM (HSG B; 0.45 in/hr) from the dropdown box; and
+
*Underlying soil – Hydrologic Soil Group: SM (HSG B; 0.45 in/hr) (selected in dropdown box); and
*Required drawdown time (hrs) which is 48 from the dropdown box.
+
*Required drawdown time: 48 hours (selected in dropdown box).
  
 
Step 8: Click on ''BMP Summary'' tab to view results for this BMP.
 
Step 8: Click on ''BMP Summary'' tab to view results for this BMP.
  
Step 9: Click on the ''OK'' button to exit the BMP properties screen.
+
Step 9: Click on the ''OK'' button to exit the ''BMP Properties'' screen.
  
 
Step 10: Click on ''Results'' tab to see overall results for the site.
 
Step 10: Click on ''Results'' tab to see overall results for the site.
Line 230: Line 265:
 
===Biofiltration Basin with an underdrain at bottom example (Version 2)===
 
===Biofiltration Basin with an underdrain at bottom example (Version 2)===
 
[[File:Schematic for example bioretention with underdrain.jpg|300px|left|thumb|alt=Schematic used  for example bioretention with underdrain at the bottom|<font size=3>Schematic used  for MIDS calculator example for bioretention with an underdrain at the bottom. In this example there is 1.4 acres of impervious parking draining to the bioretention basin.  Pervious area is 0.8 acres and includes the turf area and the bioretention BMP.  See Step 1.</font size>]]
 
[[File:Schematic for example bioretention with underdrain.jpg|300px|left|thumb|alt=Schematic used  for example bioretention with underdrain at the bottom|<font size=3>Schematic used  for MIDS calculator example for bioretention with an underdrain at the bottom. In this example there is 1.4 acres of impervious parking draining to the bioretention basin.  Pervious area is 0.8 acres and includes the turf area and the bioretention BMP.  See Step 1.</font size>]]
[[File:Tree trench no drain example site information tab.png|300px|thumb|alt=screen shot site information tab with underdrain at the bottom|<font size=3>Screen shot of the Site information tab for the MIDS example for bioretention with an underdrain at the bottom. The User must input impervious acres and zip code.  Other fields are optional. See Step 2.</font size>]]
+
[[File:Tree trench no drain example site information tab.png|300px|thumb|alt=screen shot Site Information tab with underdrain at the bottom|<font size=3>Screen shot of the Site Information tab for the MIDS example for bioretention with an underdrain at the bottom. The user must input impervious acres and ZIP code.  Other fields are optional. See Step 2.</font size>]]
 
[[file:Schematic for example bioretention with underdrain2.jpg|300px|thumb|left|alt=Schematic used  for example bioretention with underdrain at the bottom.|<font size=3>Schematic used for the MIDS calculator example for bioretention with an underdrain at the bottom.  See Step 1.</font size>]]
 
[[file:Schematic for example bioretention with underdrain2.jpg|300px|thumb|left|alt=Schematic used  for example bioretention with underdrain at the bottom.|<font size=3>Schematic used for the MIDS calculator example for bioretention with an underdrain at the bottom.  See Step 1.</font size>]]
[[File:Schematic tab bioretention with elevated underdrain example.png|300px|thumb|alt=Screen shot of schematic tab for bioretention with underdrain at the bottom example|<font size=3>Screen shot of the Schematic tab for the MIDS calculator example for bioretention with an underdrain at the bottom.  See Step 3.</font size>]]
+
[[File:Schematic tab bioretention with elevated underdrain example.png|300px|thumb|alt=Screen shot of Schematic tab for bioretention with underdrain at the bottom example|<font size=3>Screen shot of the Schematic tab for the MIDS calculator example for bioretention with an underdrain at the bottom.  See Step 3.</font size>]]
  
An unlined biofiltration basin with an underdrain at the bottom is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area (turf area and the bioretention BMP area). All of the runoff from the watershed will be treated by the biofiltration basin. The soils across the area have a unified soils [http://stormwater.pca.state.mn.us/index.php/Design_infiltration_rates classification of SM] (HSG type B soil). The surface overflow is located 1 ft above the media surface.  The surface area of the biofiltration basin at the overflow point will be 6534 square feet.  The area is 5600 square feet at the media surface.  The area at the media-soil interface is 3320 square feet. The total media depth will be 3 feet.  The media will be [http://stormwater.pca.state.mn.us/index.php/Construction_specifications_for_bioretention#Guidance_for_bioretention_media_composition Media Mix C], which is mostly sand resulting in a difference between the media [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties wilting point and field capacity] of 0.11 cubic feet per cubic foot and a difference between the [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties media porosity and field capacity] of 0.26 cubic feet per cubic foot. The P content of the media is less than 30 mg/kg (milligrams per kilogram) and no [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption soil amendments] will be used to attenuate phosphorus. The following steps detail how this system would be set up in the MIDS calculator.
+
An unlined biofiltration basin with an underdrain at the bottom is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area (turf area and the bioretention BMP area). All of the runoff from the watershed will be treated by the biofiltration basin. The soils across the area have a unified soils [http://stormwater.pca.state.mn.us/index.php/Design_infiltration_rates classification of SM (HSG type B soil)]. The surface overflow is located 1 ft above the media surface.  The surface area of the biofiltration basin at the overflow point will be 6534 square feet.  The area is 5600 square feet at the media surface.  The area at the media-soil interface is 3320 square feet. The total media depth will be 3 feet.  The media will be [http://stormwater.pca.state.mn.us/index.php/Construction_specifications_for_bioretention#Guidance_for_bioretention_media_composition Media Mix C], which is mostly sand resulting in a difference between the media [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties wilting point and field capacity] of 0.11 cubic feet per cubic foot and a difference between the [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties media porosity and field capacity] of 0.26 cubic feet per cubic foot. The P content of the media is less than 30 mg/kg (milligrams per kilogram) and no [http://stormwater.pca.state.mn.us/index.php/Soil_amendments_to_enhance_phosphorus_sorption soil amendments] will be used to attenuate phosphorus. The following steps detail how this system would be set up in the MIDS calculator.
  
 
Step 1: Determine the watershed characteristics of your entire site.  For this example we have a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious area in type B soils.  The pervious area includes the turf area and the area of the biofiltration basin.   
 
Step 1: Determine the watershed characteristics of your entire site.  For this example we have a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious area in type B soils.  The pervious area includes the turf area and the area of the biofiltration basin.   
Line 240: Line 275:
 
Step 2: Fill in the site specific information into the ''Site Information'' tab.  This includes entering a Zip Code (55414 for this example) and the watershed information from Step 1. The Managed turf area includes the turf area and the area of the bioretention basin.  Zip code and impervious area must be filled in or an error message will be generated.  Other fields on this screen are optional.
 
Step 2: Fill in the site specific information into the ''Site Information'' tab.  This includes entering a Zip Code (55414 for this example) and the watershed information from Step 1. The Managed turf area includes the turf area and the area of the bioretention basin.  Zip code and impervious area must be filled in or an error message will be generated.  Other fields on this screen are optional.
  
Step 3: Go to the Schematic tab and drag and drop the ''Bioretention basin (with underdrain)'' icon into the ''Schematic Window''
+
Step 3: Go to the ''Schematic'' tab and drag and drop the ''Bioretention basin (with underdrain)'' icon into the ''Schematic'' window.
  
Step 4: Open the BMP properties for the bioretention basin by right clicking on the “Bioretention basin (with underdrain)” icon and selecting ''Edit BMP properties'', or by double clicking on the ''Bioretention basin (with underdrain)'' icon.  
+
Step 4: Open the BMP properties for the bioretention basin by right clicking on the “Bioretention basin (with underdrain)” icon and selecting ''Edit BMP Properties'', or by double clicking on the ''Bioretention basin (with underdrain)'' icon.  
  
Step 5: If help is needed click on the ''Minnesota Stormwater Manual Wiki'' link or the ''Help'' button to review input parameter specifications and calculation specific to the “Bioretention basin (with underdrain)” BMP.
+
Step 5: If help is needed click on the ''Minnesota Stormwater Manual Wiki'' link or the ''Help'' button to review input parameter specifications and calculations pertinent to the “Bioretention basin (with underdrain)” BMP.
  
Step 6: Determine the watershed characteristics for the Bioretention basin.  For this example the entire site is draining to the bioretention basin.  The watershed parameters therefore include a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. There is no routing for this BMP. Fill in the BMP specific watershed information (1.4 acres on impervious cover and 0.8 acres of Managed turf in B soils).
+
Step 6: Determine the watershed characteristics for the biofiltration basin.  For this example the entire site is draining to the biofiltration basin.  The watershed parameters therefore include a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. There is no routing for this BMP. Fill in the BMP specific watershed information in the ''Watershed'' tab (1.4 acres on impervious cover and 0.8 acres of Managed turf in B soils).
  
 
<gallery caption="MIDS calculator screen shots for inputs for bioretention with an underdrain at the bottom. Click on an image for enlarged view." widths="140px">
 
<gallery caption="MIDS calculator screen shots for inputs for bioretention with an underdrain at the bottom. Click on an image for enlarged view." widths="140px">
File:Watershed tab bioretention with elevated underdrain example.png|alt=Schematic showing watershed tab for bioretention with underdrain at bottom|Screen showing watershed tab for bioretention with an underdrain at the bottom. See Step 6.
+
File:Watershed tab bioretention with elevated underdrain example.png|alt=Schematic showing Watershed tab for bioretention with underdrain at bottom|Screen showing Watershed tab for bioretention with an underdrain at the bottom. See Step 6.
File:BMP Parameters tab bioretention with underdrain example 1.png|alt=Schematic showing BMP Parameters tab for bioretention with underdrain at the bottom|MIDS calculator screen shot showing BMP Parameters tab for bioretention with an underdrain at the bottom. See Step 7.
+
File:BMP Parameters tab bioretention with underdrain example 1.png|alt=Schematic showing BMP Parameters tab for bioretention with underdrain at the bottom|MIDS calculator screen shot showing BMP Parameters tab for bioretention with an underdrain at the bottom. See Step 7.
File:BMP Parameters tab bioretention with underdrain example 2.png|alt=Schematic showing BMP Parameters tab for bioretention with underdrain at the bottom|MIDS calculator screen shot showing BMP Parameters tab for bioretention with an underdrain at the bottom. See Step 7.
+
File:BMP Parameters tab bioretention with underdrain example 2.png|alt=Schematic showing BMP Parameters tab for bioretention with underdrain at the bottom|MIDS Calculator screen shot showing BMP Parameters tab for bioretention with an underdrain at the bottom. See Step 7.
File:BMP Summary tab bioretention with underdrain example.png|alt=screen shot BMP Summary tab for bioretention with underdrain at the bottom|MIDS calculator screen shot of the BMP Summary tab for bioretention with an underdrain at the bottom. See Step 8.
+
File:BMP Summary tab bioretention with underdrain example.png|alt=screen shot BMP Summary tab for bioretention with underdrain at the bottom|MIDS Calculator screen shot of the BMP Summary tab for bioretention with an underdrain at the bottom. See Step 8.
File:results tab bioretention with elevated underdrain example.png|alt=Screen shot results tab for bioretention with an underdrain at the bottom example|MIDS calculator screen shot for the example of a bioretention system with an underdrain at the bottom. See Step 10.
+
File:results tab bioretention with elevated underdrain example.png|alt=Screen shot of Results tab for bioretention with an underdrain at the bottom example|Screen shot of the Results tab for the example of a bioretention system with an underdrain at the bottom. See Step 10.
 
</gallery>
 
</gallery>
  
Step 7: Enter in the BMP design parameters into the ''BMP parameters'' tab.  Bioretention basin with an underdrain requires the following entries.
+
Step 7: Enter in the BMP design parameters into the ''BMP Parameters'' tab.  This bioretention basin example with an underdrain at the bottom of the media requires the following entries:
 
*Is the underdrain elevated above native soils – No;
 
*Is the underdrain elevated above native soils – No;
 
*Are the sides of the basin lined with an impermeable liner – No;
 
*Are the sides of the basin lined with an impermeable liner – No;
 
*Is the bottom of the basin lined with an impermeable liner – No;
 
*Is the bottom of the basin lined with an impermeable liner – No;
*Surface area of overflow which is 6534 square feet;
+
*Surface area of overflow [A<sub>O</sub>]: 6534 square feet;
*Surface area at media surface which is 5600 square feet;
+
*Media surface area [A<sub>M</sub>]: 5600 square feet;
*Bottom surface area (area at media-soil interface) which is 3230 square feet;
+
*Bottom surface area (area at media-soil interface) [A<sub>B</sub>]: 3230 square feet;
*Overflow depth which is 1 foot;
+
*Overflow depth [D<sub>O</sub>]: 1 foot;
*Total media depth which is 3 feet;
+
*Total media depth [D<sub>M</sub>]: 3 feet;
*Media field capacity minus wilting point which is 0.11 cubic feet per cubic foot;
+
*Media field capacity minus wilting point [FC-WP]: 0.11 cubic feet per cubic foot;
*Media porosity minus field capacity which is 0.26 cubic feet per cubic foot;
+
*Media porosity minus field capacity [n-FC]: 0.26 cubic feet per cubic foot;
 
*Is a tree(s) planted in the BMP – No;
 
*Is a tree(s) planted in the BMP – No;
*Bioretention planting media mix which is Media Mix C;
+
*Bioretention planting media mix Media Mix C (selected from the dropdown box);
*Is the P content of the media less than 30 mg/kg which autofills to “Yes” for Media Mix C;
+
*Is the P content of the media less than 30 mg/kg –  autofills to “Yes” for Media Mix C;
*Is a soil amendment used No;
+
*Is a soil amendment used to attenuate phosphorus– No;
*Underlying soil – Hydrologic Soil Group which is SM (HSG B; 0.45 in/hr) from the dropdown box; and
+
*Underlying soil – Hydrologic Soil Group: SM (HSG B; 0.45 in/hr) (selected from the dropdown box); and
*Required drawdown time (hrs) which is 48 from the dropdown box.
+
*Required drawdown time: 48 hrs (selected from the dropdown box).
  
 
Step 8: Click on ''BMP Summary'' tab to view results for this BMP.
 
Step 8: Click on ''BMP Summary'' tab to view results for this BMP.
  
Step 9: Click on the ''OK'' button to exit the BMP properties screen.
+
Step 9: Click on the ''OK'' button to exit the ''BMP properties'' screen.
  
 
Step 10: Click on ''Results'' tab to see overall results for the site.
 
Step 10: Click on ''Results'' tab to see overall results for the site.
  
 
==Requirements==
 
==Requirements==
[[File:Illustration of depth to bedrock or wt.jpg|thumb|300px|alt=image illustrating separation distance to bedrock or seasonal high water table|<font size=2>Measurement of depth from the bottom of the infiltration BMP (bioretention with elevated underdrain) to the seasonally high water table or bedrock. Note that there must be a minimum of 2 feet separation when soils beneath the BMP are ripped, with a total separation distance of 3 feet or more. Infiltration BMPs include any BMP that allows water to infiltrate into the underlying soil.</font size>]]
+
[[File:3 foot separation b.png|thumb|300px|alt=image illustrating separation distance to bedrock or seasonal high water table|<font size=3>Measurement of depth from the bottom of the infiltration BMP (bioretention with elevated underdrain) to the seasonally high water table or bedrock. Note that there must be a minimum of 2 feet separation when soils beneath the BMP are ripped, with a total separation distance of 3 feet or more. Infiltration BMPs include any BMP that allows water to infiltrate into the underlying soil.</font size>]]
  
 
{{alert|The following are requirements of the [http://www.pca.state.mn.us/index.php/water/water-types-and-programs/stormwater/construction-stormwater/index.html Minnesota Construction Stormwater General Permit]|alert-danger}}
 
{{alert|The following are requirements of the [http://www.pca.state.mn.us/index.php/water/water-types-and-programs/stormwater/construction-stormwater/index.html Minnesota Construction Stormwater General Permit]|alert-danger}}
*3 foot separation from the bottom of an infiltration system (bioretention with elevated underdrain) to the seasonal high water table
+
*At least a 3 foot separation from the bottom of an infiltration system (includes bioretention with elevated underdrain) to the seasonal high water table
*Use the most restrictive infiltration rate within 3 feet of the bottom of the BMP
+
*If soils below the bottom of the infiltration system are ripped to promote infiltration, at least 2 feet of separation from the bottom of the ripped zone to the [[Glossary#S|seasonal high water table]]
 +
*Use the most restrictive infiltration rate within 5 feet of the bottom of the BMP
 
*For [[Determining soil infiltration rates|measured infiltration rates]], apply a safety factor of 2
 
*For [[Determining soil infiltration rates|measured infiltration rates]], apply a safety factor of 2
*Pretreatment for infiltration systems (bioretention with elevated underdrain)
+
*[[Pretreatment]] for infiltration systems
  
 
==Recommendations==
 
==Recommendations==
{{alert|The following are recommendations for inputs into the MIDS calculator|alert-warning}}
+
{{alert|The following are recommendations for inputs into the MIDS Calculator|alert-warning}}
 
*Drawdown time of 24 hours when the discharge is to [[Sensitive waters and other receiving waters|trout streams]]
 
*Drawdown time of 24 hours when the discharge is to [[Sensitive waters and other receiving waters|trout streams]]
*[[Determining soil infiltration rates|Field tested infiltration rates]] rather than table values
+
*Use of [[Determining soil infiltration rates|field tested infiltration rates]] rather than table values
  
 
==Information==
 
==Information==
{{alert|The following information may be useful in determining inputs for the MIDS calculator|alert-info}}
+
{{alert|The following information may be useful in determining inputs for the MIDS Calculator|alert-info}}
 
*Guidance on determining [[Design criteria for bioretention#Determine site infiltration rates (for facilities with infiltration and/or recharge)|infiltration rates]]
 
*Guidance on determining [[Design criteria for bioretention#Determine site infiltration rates (for facilities with infiltration and/or recharge)|infiltration rates]]
 
*Information on [[Stormwater infiltration and constraints on infiltration|site constraints]] (shallow soil, karst, etc.)
 
*Information on [[Stormwater infiltration and constraints on infiltration|site constraints]] (shallow soil, karst, etc.)
 
*Guidance on [[Pre-treatment|pretreatment]]
 
*Guidance on [[Pre-treatment|pretreatment]]
 +
*Information on [[Design criteria for bioretention#Materials specifications - filter media|soil mixes]]
 
*[[Construction specifications for bioretention|Construction specifications for bioretention BMPs]]
 
*[[Construction specifications for bioretention|Construction specifications for bioretention BMPs]]
 
*Information on [[Operation and maintenance of bioretention|operation and maintenance of bioretention BMPs]].
 
*Information on [[Operation and maintenance of bioretention|operation and maintenance of bioretention BMPs]].
  
 
==Links to MIDS pages==
 
==Links to MIDS pages==
 +
*[[Overview of Minimal Impact Design Standards (MIDS)]]
 
*[[Performance goals for new development, re-development and linear projects]]
 
*[[Performance goals for new development, re-development and linear projects]]
*[[Flexible treatment options]]
+
*[[Design Sequence Flowchart-Flexible treatment options]]
*[[Ordinance goals]]
+
*[[Community Assistance Package]]
 
*[[MIDS calculator]]
 
*[[MIDS calculator]]
 +
*[[Performance curves for MIDS calculator]]
 +
*[[Training and workshop materials and modules]]
 +
*[[Technical documents]]
 +
 +
<noinclude>
 +
==Related pages==
 +
*[[Bioretention terminology]] (including types of bioretention)
 +
*[[Overview for bioretention]]
 +
*[[Design criteria for bioretention]]
 +
*[[Construction specifications for bioretention]]
 +
*[[Operation and maintenance of bioretention]]
 +
*[[Assessing the performance of bioretention]]
 +
*[[Cost-benefit considerations for bioretention]]
 +
*[[Calculating credits for bioretention]]
 +
*[[Soil amendments to enhance phosphorus sorption]]
 +
*[[Summary of permit requirements for bioretention]]
 +
*[[Supporting material for bioretention]]
 +
*[[External resources for bioretention]]
 +
*[[References for bioretention]]
 +
*[[Requirements, recommendations and information for using bioretention with no underdrain BMPs in the MIDS calculator]]
 +
*[[Requirements, recommendations and information for using bioretention with an underdrain BMPs in the MIDS calculator]]
 +
 +
[[Category:Level 3 - Models and modeling/Specific models/MIDS Calculator]]
 +
[[Category:Level 3 - Best management practices/Structural practices/Bioretention‏‎]]
 +
</noinclude>

Latest revision as of 13:27, 29 January 2023

Symbol for Bioretention basin (with underdrain)) used in MIDS calculator
Symbol for Bioretention basin (with underdrain) used in MIDS calculator.
Screen shot of Watershed tab for bioretention with underdrain. The user must input a value for impervious area or the BMP will not provide volume and pollutant reduction. Other fields are optional.
Screen shot Watershed tab for Bioretention basin (with underdrain).The user must input a value for impervious area or the BMP will not provide volume and pollutant reduction. Other fields are optional.
Screen shot of the BMP Parameters tab for a Bioretention basin (with underdrain). The user must enter values for all blank cells.
Screen shot of the BMP Parameters tab for a Bioretention basin (with underdrain). The user must enter values for all blank cells.

For a bioretention (aka biofiltration) BMP with an underdrain at the bottom of the engineered media, most of the stormwater captured by the BMP is filtered and lost to the underdrain. However, some stormwater infiltrates through the basin bottom and sidewalls if these do not have an impermeable liner. Volume retention also occurs by evapotranspiration through the vegetation in the biofiltration BMP. For biofiltration systems with an elevated underdrain, additional volume retention is achieved through infiltration of water stored in the pore spaces of the engineered media between the underdrain invert and the native soils. All pollutants in infiltrated water are credited as being removed, while a portion of the pollutant loads in the stormwater that flows through the underdrain are removed through filtration.

NOTE: A bioretention device with an installed underdrain is a type of biofiltration device, since some portion of the treated water is filtered and discharged downstream rather than infiltrated. MPCA believes that biofiltration is the more generally applicable term for this BMP type; but the reader will currently find both of these terms on relevant pages, due to MPCA's understanding that a variety of terms are currently common in stormwater management.

Version 4 changes

Information: Updates have been made to Version 4 of the MIDS Calculator

MIDS calculator user inputs for biofiltration basin (with underdrain)

For a biofiltration with underdrain system, the user must input the following parameters to calculate the volume and pollutant load reductions associated with the BMP.

  • Watershed tab:
    • BMP Name: this cell is auto-filled but can be changed by the user.
    • Routing/downstream BMP: if this BMP is part of a treatment train and water is being routed from this BMP to another BMP, the user selects the name of the BMP to which water is being routed from the dropdown box. All water must be routed to a single downstream BMP. Note that the user must include the BMP receiving the routed water in the Schematic or the BMP will not appear in the dropdown box.
    • BMP Watershed Area: BMP watershed areas are the areas draining directly to the BMP. Values can be added for four soil types (Hydrologic Soil Groups (HSG) A, B, C, D) and for three Land Cover types (Forest/Open Space, Managed Turf, and Impervious). The surface area of the BMP should be included as a managed turf land cover of the hydrologic soil type of the native soils that are located under the BMP. Units are in acres.
  • BMP Parameters tab:
    • Is the underdrain elevated above native soils?: This is a YES/NO question. Answering YES means the underdrain is elevated within the media (i.e., Biofiltration with a raised underdrain). This creates storage capacity between the underdrain and the native soils. Answering NO means that the underdrain is not elevated within the media and is directly above the native soils with no storage capacity below the underdrain (i.e., Biofiltration with underdrain at the bottom).
    • Are the sides of the basin lined with an impermeable liner?: This is a YES/NO question. Answering YES means the sides of the basin are lined, preventing water from infiltrating into the native soils. Answering NO means the sides are not lined and infiltration is allowed through the side of the basin into the native soils.
    • Is the bottom of the basin lined with an impermeable liner?: This is a YES/NO question. Answering YES means the bottom of the basin is lined, preventing water from infiltrating into the native soils. Answering NO means the bottom is not lined and infiltration is allowed through the bottom of the basin into the native soils.
    • Surface area at overflow (AO): This is the surface area of the BMP at the lowest outlet point of the surface overflow from the ponding area of the BMP. Units are in square feet.
    • Media surface area (AM): This is the surface area at the bottom of the ponded water within the BMP. This is therefore the area at the surface of the engineered media. Units are in square feet.
    • Surface area at underdrain (AU): This is the surface area of the BMP at the invert elevation of the underdrain. If the response to "Is the underdrain elevated above native soils?" is set to NO, then this cell will become inactive and populated with the Bottom surface area value. Units are in square feet.
    • Bottom surface area (AB): This is the surface area at the bottom of the engineered media. It represents the area where the engineered media changes to native soils. Units are in square feet
    • Overflow depth (DO): This is the maximum depth of ponded water within the BMP (i.e., vertical distance from the overflow elevation to the top of the soil or media). Units are in feet. The maximum allowable depth is 1.5 feet.
    • Total media depth (DM): This is the depth of the engineered media between the media surface and the native soils. Units are in feet.
    • Depth below underdrain (DU): This is the depth of the media between the underdrain invert and the native soils. If the response to "Is the underdrain elevated above native soils?" is set to NO, then this cell will become inactive and populated with a 0. Units are in feet.
    • Media field capacity minus wilting point (FC-WP): This is the amount of water between field capacity and the permanent wilting point stored in the media above the underdrain. This is water often considered to be available for uptake by plants. If multiple types of media are used in the BMP, this value should be a weighted average of the soil water storage values of the media installed above the underdrain. Values for field capacity and wilting point based on soil type can be found here. Units are in cubic feet of water per cubic feet of media. The recommended range for this value is 0.05 to 0.17.
    • Media porosity minus field capacity (n - FC) - This is the amount of water between media porosity and field capacity stored in the media between the underdrain invert and the bottom of the media (top of native soil). If multiple types of media are used in the BMP, this value should be a weighted average of the soil water storage values of the media installed between the underdrain and the native soils. Values for porosity and field capacity based on soil type can be found here. Units are in cubic feet of pore space per cubic feet of media. The recommended range for this value is 0.15 to 0.35.
    • Is a tree(s) planted in the BMP?: This is a YES/NO question. If trees are planted within the biofiltration basin then additional volume loss associated with evapotranspiration will be applied.
    • Bioretention planting media mix: The user selects the type of media mix installed for planting from a predefined list of media mixes: Media mix A (water quality blend), Media mix B (enhanced filtration blend), Media mix C (North Carolina State University water quality blend), Media mix D, or Other. This value is used to determine the annual phosphorus load reduction credit.
    • Is the P content of the media less than 30 mg/kg?: This is a YES/NO question. The P content of the planting media should be tested using the Mehlich 3 test or an acceptable alternative method. Select YES if the P content of the planting media is less than 30 milligrams per kilogram and NO if it is greater. P content testing is not needed for planting media C or D; therefore, this item will automatically populate to YES if one of those two media types are selected. This value is used to determine the annual phosphorus load reduction credit.
    • Do you have a properly designed phosphorus treatment layer or area in your system (e.g. iron enhanced layer)?: This is a YES/NO question. Answer YES if the bioretention filter media contains soil amendments to enhance phosphorus sorption and NO if amendments are not used. This value is used to determine the annual phosphorus load reduction credit.
    • Underlying soil - Hydrologic Soil Group: The user selects the most restrictive soil (lowest hydraulic conductivity) within the 5 feet below the media/native soil interface of the biofiltration basin. There are 14 soil options that fall into 4 different Hydrologic Soil Groups (Hydrologic Soil Group (HSG) A, B, C, or D) for the user. Once a soil type is selected, the corresponding infiltration rate will populate the Infiltration rate of underlying soils field. The user may also select User Defined. This selection will activate the User Defined Infiltration Rate cell, allowing the user to enter a different value from those in the predefined selection list. The maximum allowable infiltration rate is 1.63 inches per hour.
    • Required drawdown time: This is the time in which the stormwater captured by and ponded within the BMP must drain into the underlying soil and/or flow through the underdrain. The user must select from predefined values of 48 or 24 hours. The MPCA Construction Stormwater General Permit requires drawdown within 48 hours, but 24 hours is Highly Recommended when discharges are to a trout stream. The calculator uses the underlying soil infiltration rate and the Depth below underdrain (DU) to check if the BMP is meeting the drawdown time requirement. The user will encounter an error and be required to enter a new Depth below underdrain (DU) if the stormwater stored in the BMP cannot drawdown in the required time. Note that the upper limit of 1.5 feet set for the Overflow depth (DO) also serves to ensure that the required drawdown time is met.
  • BMP Summary tab: The BMP Summary tab summarizes the volume and pollutant reductions provided by the specific BMP. It details the performance goal volume reductions and annual average volume, dissolved P, particulate P, and TSS load reductions. Included in the summary are the total volume and pollutant loads received by the BMP from its direct watershed, from upstream BMPs and a combined value of the two. Also included in the summary are the volume and pollutant load reductions provided by the BMP, along with the volume and pollutant loads that exit the BMP through the outflow. This outflow load and volume is what is routed to the downstream BMP, if one is defined in the Watershed tab. Finally, percent reductions are provided for the percent of the performance goal achieved, percent annual runoff volume retained, total percent annual particulate phosphorus reduction, total percent annual dissolved phosphorus reduction, total percent annual TP reduction, and total percent annual TSS reduction.

Model input requirements and recommendations

If the following requirements for inputs into the MIDS calculator are not met, then an error message will inform the user to change the input to meet the requirement.

  • Overflow depth (DO) cannot be greater than 1.5 feet
  • Surface areas must be equal to or less than all surface areas at higher elevations
  • The Depth below underdrain (DU) cannot be greater than the Total media depth (DM)
  • Infiltration rate of underlying soils cannot exceed 1.63 inches per hour
  • If the user enters a value for field capacity minus wilting point (FC-WP) or porosity minus field capacity (n-FC) outside the recommended range a warning will appear. The user will not be required to enter a new value.
  • The water below the underdrain must meet the user-specifed drawdown time requirement. The drawdown time requirement is checked by comparing the specified drawdown time with the calculated drawdown time (DDTcalc), given by

\(DDT_{calc}=D_U / (I_R / 12)\)

Where

DU is the depth below the underdrain (ft); and
IR is the infiltration rate of the native soils (in/hr).

If DDTcalc is greater than the user-specified required drawdown time then the user will be prompted to enter a new depth below the underdrain or infiltration rate of the native soils.

Methodology

Required treatment volume

Required treatment volume, or the volume of stormwater runoff delivered to the BMP, equals the performance goal (1.1 inches for MIDS or user-specified performance goal) times the impervious area draining to the BMP plus any water routed to the BMP from an upstream BMP. This stormwater is delivered to the BMP instantaneously.

Volume reduction

The total estimated Volume reduction capacity of BMP [V] is the sum of infiltration and ET occurring in the biofiltration BMP, and is calculated with user-provided inputs. For this BMP, the location of the underdrain determines how the infiltration component is calculated. If the underdrain is located at the bottom of the BMP, then the infiltration credit is based on infiltration into the bottom of the BMP (Vinfb) and into side slopes of the BMP above the underdrain (Vinfs). In contrast, if the underdrain is elevated above the bottom of the BMP, then the infiltration credit is based on the volume capacity of the bioretention base (VBB) between the underdrain and the native soils, and infiltration into the side slopes of the BMP above the underdrain (Vinfs). Both types of underdrain configurations can receive credit for ET in the media above the underdrain (VET). A biofiltration system with an elevated underdrain thus behaves as a dual system, with the portion above the drain acting like a biofiltration system with an underdrain at the bottom and the portion below the underdrain acting like a bioinfiltration system.

The Volume of retention provided by BMP is the total instantaneous volume credit that can be claimed for that BMP, and is determined by comparing the Volume reduction capacity of BMP [V] to the Required treatment volume.

Volume reduction from infiltration

Underdrain located at bottom of engineered media: Volume reduction from basin bottom infiltration (Vinfb)

Even with an underdrain installed at the bottom of the engineered media, under saturated conditions some water will infiltrate through the bottom soils rather than pass through the underdrain. This Volume reduction from basin bottom infiltration (Vinfb) is given by

\(V_{Inf_b} = I_R * (DDT) * A_B / (12in/ft) = 0.06 * (DDT) * A_B / (12in/ft)\)

Where

IR is an infiltration rate into the native soils of 0.06 inches per hour;
AB is the surface area at the bottom of the BMP (ft2); and
DDT is the drawdown time (hr).

The default infiltration rate is set at 0.06 inches per hour to represent a D soil. This rate was selected because it is assumed most of the stormwater will pass through the underdrain before it can infiltrate through the bottom of the BMP. This may be a conservative assumption if underdrains are small, spaced far apart, and the underlying soil has an infiltration rate greater than 0.06 inches per hour. Conversely, more closely spaced or larger underdrains may allow the basin to drain in less than the required drawdown time, resulting in a slight overestimation of (Vinfb). If the user specifies that an impermeable liner is present at the bottom of the BMP, then no credit is given for infiltration into the bottom soils.

Elevated underdrain: Volume reduction stored below the underdrain

If the underdrain is elevated above the bottom of the BMP, then storage capacity becomes available in the media between the underdrain and the native soils. In systems with an elevated underdrain, this Volume reduction stored below underdrain is credited instead basin bottom infiltration (VInfb) credit that is given when the underdrain is at the bottom of the engineered media. This Volume reduction stored below underdrain (VU) is given by

\(V_U= (A_U + A_B) / 2 * (n - FC) * D_U \)

Where:

AU is the surface area at the underdrain (ft2);
AB is the surface area at the bottom of the basin (ft2);
(n - FC) is the media porosity minus field capacity of the soils; and
DU is the depth of the media below the underdrain (ft).

The stored water must drain within the specified drawdown time. The underlying soil controls the infiltration rate. The user must input the soil with the most restrictive hydraulic conductivity in the 5 feet directly below the basin (i.e. below the bottom of the engineered media). If the user specifies that an impermeable liner is present at the bottom of the BMP, then no volume reduction credit is given for storage below the underdrain.

Volume reduction from basin sides infiltration (Vinfs): underdrain elevated or at bottom of engineered media

Under saturated conditions within the filter media, water will infiltrate through any existing sloped sidewalls of the basin as the stormwater draws down through the underdrain. Stormwater lost from a sloped sidewall (Vinfs) is considered to infiltrate vertically into the surrounding soil. This credit is calculated whether the underdrain is elevated or at the base of the engineered media. The volume of water infiltrated through the sidewalls is given by

\(V_{Inf_s} = I_R * (DDT / 2) * (A_O - A_U ) / (12in/ft) = 0.06 * (DDT / 2) * (A_O - A_U ) / (12in/ft)\)

Where:

AO is the surface area at overflow (ft2);
AU is the surface area at the underdrain (ft2); and
DDT is the drawdown time (hr).

Due to the fact that drawdown occurs as a continuous process, basin sides infiltration is not presumed to occur along the entire height of the sidewall during the entire drawdown time. For example, at "time zero", the entire sidewall should be exposed to saturated conditions and exhibit sidewall infiltration; but at the end of the drawdown period, there would theoretically be no section of the sidewall that is exposed to saturated conditions. Therefore, the drawdown time used in the calculation of (Vinfs) is reduced by a factor of 2 to account for the drop in water level and to approximate the "average" water level within the BMP during the drawdown period. The drop in water level is thus assumed to be linear over the drawdown time. A conservative default infiltration rate of 0.06 inches per hour is used because it is assumed that most of the stormwater will pass through the underdrain before it can infiltrate through the sidewalls of the BMP. If the user specifies that an impermeable liner is present on the sides of the BMP or if the sidewalls are not sloped (i.e., AO = AU), then no credit is given for infiltration into the side soils.

Volume reduction from evapotranspiration (ET)

In addition to the credit given for infiltration, a biofiltration BMP can achieve volume reduction through ET. The volume of water lost through evapotranspiration (VET) is the smaller of two calculated values, potential ET and measured ET.

Potential ET (ETpot)

Potential ET (ETpot) is equal to the amount of water stored between field capacity and the wilting point in the media above the underdrain, and is given by

\(ET_{pot} = (D_M - D_U ) * (A_M + A_U) / 2 * (FC - WP)\)

Where

DM is the total media depth (ft);
DU is the depth under the underdrain (ft);
AM is the surface area of the media (ft2);
AU is the surface area at the underdrain (ft2); and
(FC – WP) is the difference between field capacity and wilting point.
Measured ET (ETmea)

Measured ET (ETmea) is the amount of water lost to ET as measured using available data. An average daily pan evaporation rate was estimated using previous measurements collected at the University of Minnesota Southwest Experiment Station at Lamberton, Minnesota (Source: Climate of Minnesota Part XII- The Hydrologic Cycle and Soil Water, 1979). A rate of 0.2 inches per day was selected, as this is an intermediate value between the summertime maximum rate and the lowest rates in October. Analysis of rainfall data indicates that a typical time period between precipitation events is 72 hours (3 days) in Minnesota. Therefore, a 3 day period is used to calculate the ETmea. A factor of 0.5 is also applied to convert the pan evaporation rate to ETmea. The ETmea volume thus equals the media surface area (AM) in square feet times the average daily ET rate in inches per day times 3 days.

\(ET_{mea} = A_M * 0.2 in/day * 0.5 * 3 days / 12 in/ft = 0.025 A_M\)

If trees are planted in the bioretention basin then ETmea is multiplied by a factor of 3.

Comparison of volume reduction capacity with volume performance goal

The sum of the volumes lost to infiltration and to ET as calculated using the appropriate methods above gives the Volume reduction capacity of BMP [V]. The MIDS calculator compares the Volume reduction capacity of BMP [V] with the Required treatment volume, and the lesser of the two values is used to populate the Volume of retention provided by BMP. This comparison between potential and actual treatment volumes ensures that the BMP does not claim more credit than is due based on the actual amount of water routed to it. The Volume of retention provided by BMP is the actual volume credit the BMP receives toward the instantaneous performance goal. For example, if the BMP is oversized the user will only receive volume credit for the Required treatment volume routed to the BMP.

Annual volume retention is assessed by converting the instantaneous Volume reduction capacity of BMP [V] to an annual volume reduction percentage. This is accomplished through the use of performance curves developed from a range of modeling scenarios. These performance curves use the Volume reduction capacity of BMP [V], the infiltration rate of the underlying soils, the percent imperviousness of the contributing watershed area, and the size of the contributing watershed to calculate the Percent annual runoff volume retained and annual Retention volume provided by BMP.

Recommended values for porosity, field capacity and wilting point for different soils.1
Link to this table.

Soil Hydrologic soil group Porosity 2 (volume/volume) Field capacity (volume/volume) Wilting point (volume/volume) Porosity minus field capacity (volume/volume)3 Field capacity minus wilting point (volume/volume)4
Sand A (GM, SW, or SP) 0.43 0.17 0.025 to 0.09 0.26 0.11
Loamy sand A (GM, SW, or SP) 0.44 0.09 0.04 0.35 0.05
Sandy loam A (GM, SW, or SP) 0.45 0.14 0.05 0.31 0.09
Loam B (ML or OL) 0.47 0.25 to 0.32 0.09 to 0.15 0.19 0.16
Silt loam B (ML or OL) 0.50 0.28 0.11 0.22 0.17
Sandy clay loam C 0.4 0.07
Clay loam D 0.46 0.32 0.15 0.14 0.17
Silty clay loam D 0.47 to 0.51 0.30 to 0.37 0.17 to 0.22 0.16 0.14
Sandy clay D 0.43 0.11
Silty clay D 0.47 0.05
Clay D 0.47 0.32 0.20 0.15 0.12

1Sources of information include Saxton and Rawls (2006), Cornell University, USDA-NIFA, Minnesota Stormwater Manual. (See References for trees)
2Soil saturation is assumed to be equal to the porosity.
3This value may be used to represent the volume of water that will drain from a bioretention media.
4This value may be used to estimate the amount of water available for evapotranspiration


Pollutant reduction

Schematic showing pollutant load reductions for infiltrated and filtration in Bioretention basin (with an underdrain)
Schematic showing how pollutant load reductions are calculated for Bioretention basin (with an underdrain). All TSS and phosphorus in infiltrated water is considered reduced. TSS loads are reduced by 60 percent for the portion of water filtered and captured by the underdrain. Phosphorus reductions in the filtered water are a function of the media and media thickness.

Pollutant removal can be accomplished both via volume reducing and non-volume reducing processes in a biofiltration BMP. Pollutant load reductions are calculated on an annual basis and are thus dependent upon the volume of water retained by the BMP through infiltration and ET and the volume of water treated by filtration in the BMP.

Pollutant reduction via volume reduction

The first step in calculating annual pollutant load reductions is to determine the annual Retention volume provided by BMP as discussed in the Volume reduction section. All pollutants in this retained water are considered captured for a 100 percent removal. Thus, while oversizing a BMP above the Required treatment volume will not provide additional credit towards the instantaneous volume performance goal, it may provide additional annual pollutant reduction through treatment of water beyond the Required treatment volume.

Pollutant reduction via non-volume reduction treatment

Stormwater that is routed to the BMP but not infiltrated or lost through ET is assumed to flow through the filter media and out the underdrain, and is indicated by the Annual outflow volume in the BMP Summary tab. The removal rate for TSS in this filtered stormwater is set at 60 percent.

Information: The Minnesota Stormwater Manual provides a TSS credit of 80 percent for biofiltration practices. A literature review suggests 80 percent may be high, but the Construction Stormwater (CSW) General Permit requires 80 percent reduction of TSS for filtration practices. Therefore, the CSW permit target cannot be achieved using the MIDS calculator. We created a MIDS calculator Excel file that utilizes 80 percent removal for biofiltration practices. Access the file at File:Corrected July 14.xls.

The removal rates for particulate phosphorus and dissolved phosphorus in the filtered stormwater depend on the user's input to three drop-down boxes: “Planting media mix”; “Is the P content of the media less than 30 mg/kg?”; and “Is a soil amendment used to attenuate phosphorus?”.

Particulate Phosphorus

The particulate phosphorus credit given for non-volume reduction treatment is either 0 percent or 80 percent depending on the media mix used and its P content.

  • If Media Mix C or D is used, or if a media mix other than C or D is used and the soil phosphorus as measured using the Mehlich 3 test or a suitable alternative test is 30 milligrams per kilogram or less, then the annual particulate phosphorus reduction credit is 80 percent of the filtered water volume.
  • If a media mix other than C or D is used and the soil phosphorus has not been determined or is greater than 30 milligrams per kilogram as measured using the Mehlich 3 test or a suitable alternative test, then the annual particulate phosphorus reduction credit is 0 percent of the filtered water volume.

NOTE: If the Olsen test is used to determine P content of the media mix, a simple conversion is required.

Dissolved Phosphorus

The dissolved phosphorus credit given for non-volume reduction treatment is between 0 percent and 60 percent depending on the media mix, the media P content, and if the media was amended to attenuate phosphorus.

  • If Media Mix C or D is used, or if a media mix other than C or D is used and soil phosphorus as measured by the Mehlich 3 test or a suitable alternative test is 30 milligrams per kilogram or less, then the annual dissolved phosphorus credit applied to the filtered water volume, expressed as a percent, is given by

\(credit = 20 percent (D_M- D_U) / 2 ft\)

Where

DM - DU represents the media depth above the underdrain (ft).

The credit is calculated as a percent reduction with a maximum value of 20 percent for media depths above the underdrain greater than 2 feet. If the media depth above the underdrain is less than 2 feet the credit is reduced equivalently.

  • If a media mix other than C or D is used and the soil phosphorus has not been determined or is greater than 30 milligrams per kilogram as measured using the Mehlich 3 test or a suitable alternative test, then the annual dissolved phosphorus credit is 0 percent of the filtered water volume.
  • An additional annual dissolved phosphorus credit of 40 percent of the filtered water volume may be received if phosphorus-sorbing amendments are used. Acceptable amendments include the following:
    • 5 percent by volume elemental iron filings above the internal water storage (IWS) layer or elevated underdrain;
    • minimum 5 percent by volume sorptive media above IWS layer or elevated underdrain;
    • minimum 5 percent by weight water treatment residuals (WTR) to a depth of at least 3.9 inches (10 centimeters);
  • For other proposed phosphorus-sorbing amendments: an additional annual dissolved phosphorus credit can be applied if and only if there is supporting third party research showing that this dissolved phosphorus reduction will occur for at least a 20-year lifespan. The credit may be commensurate with existing research results, with the understanding that the user may be asked to provide this documentation.

Phosphorus credits for bioretention systems with an underdrain. This includes tree trenches and dry swales.
Link to this table

Particulate phosphorus (PP) Dissolved phosphorus (DP)
Is Media Mix C or D being used or, if using a mix other than C or D, is the media phosphorus content 30 mg/kg or less per the Mehlich 3 (or equivalent) test1?
  • If yes, particulate credit = 100% of the particulate fraction (assumed to be 55% of total P)
  • If no or unknown, particulate credit = 0%

The assumption of 55 percent particulate phosphorus and 45 percent dissolved phosphorus is likely inaccurate for certain land uses, such as industrial, transportation, and some commercial areas. Studies indicate particulate phosphorus comprises a greater percent of total phosphorus in these land uses. It may therefore be appropriate to modify the above equation with locally derived ratios for particulate and dissolved phosphorus. For more information on fractionation of phosphorus in stormwater runoff, link here.


Example PP removal credit

  • Particulate fraction (55% of TP) * removal rate for that fraction (80% for bioretention and tree trench and 68% for swale main channel) = 0.55 * 0.80 = 0.44 or 44% for bioretention and tree trench (with underdrain) and 0.55 * 0.68 or 36% for swale main channel (with underdrain)
  • If particulate is 75% of TP, removal = 0.75 * 0.80 or 60% for bioretention and tree trench (with underdrain) and 0.75 * 0.68 or 51% for dry swale
1. Is Media Mix C or D being used or, if using a mix other than C or D, is the media phosphorus content 30 mg/kg or less per the Mehlich 3 (or equivalent) test1?
  • If yes, credit as a % (up to a maximum of 20%) = 20 * (depth of media above underdrain, in feet/2)
  • If no or unknown, credit = 0%

2. Does the system include approved P-sorbing soil amendments2?

  • If yes, additional 40% credit


Example DP removal credit

  • DP removal if dissolved credit is 20% = Dissolved fraction (45%) * removal rate for that fraction (20%) = 0.09 or 9 percent
  • Adjust DP removal if depth is less than 2 feet. Example depth = 1 foot then DP removal = 0.45 * 10% * 1/2 = 0.045
  • Adjust DP removal if dissolved credit is higher due to use of P-sorbing soil amendments
  • Adjust if the fraction (percentage) of DP is different than 45%

The assumption of 55 percent particulate phosphorus and 45 percent dissolved phosphorus is likely inaccurate for certain land uses, such as industrial, transportation, and some commercial areas. Studies indicate particulate phosphorus comprises a greater percent of total phosphorus in these land uses. It may therefore be appropriate to modify the above equation with locally derived ratios for particulate and dissolved phosphorus. For more information on fractionation of phosphorus in stormwater runoff, link here.

TP removal = PP removal + DP removal

1Other widely accepted soil P tests may be used. Note: a basic conversion of test results may be necessary
2Acceptable P sorption amendments include

  • 5% by volume elemental iron filings above IWS or elevated underdrain
  • minimum 5% by volume sorptive media above IWS or elevated underdrain
  • minimum 5% by weight water treatment residuals (WTR) to a depth of at least 10 cm
  • other P sorptive amendments with supporting third party research results showing P reduction for at least 20 year lifespan, P credit commensurate with research results


NOTE: The user can modify event mean concentrations (EMCs) on the Site Information tab in the calculator. Default concentrations are 54.5 milligrams per liter for total suspended solids (TSS) and 0.3 milligrams per liter for total phosphorus (particulate plus dissolved). The calculator will notify the user if the default is changed. Changing the default EMC will result in changes to the total pounds of pollutant reduced.

Routing

A biofiltration basin can be routed to any other BMP, except for a green roof, a swale side slope, or any BMP that would cause stormwater to be rerouted back to the biofiltration basin already in the sequence. All BMPs can be routed to a biofiltration, except for a swale side slope BMP.

Assumptions for biofiltration basin with underdrain

The following general assumptions apply in calculating the credit for a biofiltration basin. If these assumptions are not followed the volume and pollutant reduction credits cannot be applied.

  • The biofiltration basin has been properly designed, constructed, and will be properly maintained.
  • Stormwater runoff entering the biofiltration basin has undergone pretreatment.
  • Stormwater captured by the BMP enters the BMP media instantaneously. This will slightly underestimate actual infiltration since some water will infiltrate through the basin bottom and sidewalls during a rain event, thus creating more volume for storage in the BMP.
  • Infiltration rates used to calculate the infiltration credit through the bottom and sidewalls of the basin are 0.06 inches per hour.
  • Evapotranspiration is independent of plant type, plant density and weather conditions.

Biofiltration Basin with an elevated underdrain example

schematic used for the MIDS calculator example bioretention with underdrain
Schematic for the MIDS calculator example for bioretention with an underdrain. Impervious surface area is 1.4 acres. Pervious surface area, which includes a turf area and the bioretention basin, is 0.8 acres. See Step 1.
screen shot Site Information tab with elevated underdrain
Screen shot of Site Information tab for bioretention with elevated underdrain example. The user must input impervious acres and ZIP code. Other fields are optional. See Step 2.
Schematic used for example bioretention with elevated underdrain
Schematic used for MIDS calculator example for bioretention with elevated underdrain. See Step 1.
Screen shot of Schematic tab for bioretention with elevated underdrain example
Screen shot of the MIDS calculator Schematic tab for the bioretention with elevated underdrain example. See Step 3.

This example was completed using Version 2 of the Calculator.

An unlined biofiltration basin with an elevated underdrain is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area (turf area and the bioretention BMP area). All of the runoff from the watershed will be treated by the biofiltration basin. The soils across the area have a unified soils classification of SM (HSG type B soil). The surface overflow is located 1 ft above the media surface. The surface area of the biofiltration basin at the overflow point will be 6534 square feet. The area is 5600 square feet at the media surface. The surface area at the invert of the underdrain will be 3948 square feet. The area at the media-soil interface is 3320 square feet. The total media depth will be 3 feet with 1 foot of media between the underdrain and the native soils. Following the MPCA Construction Stormwater General Permit requirement, the water below the underdrain in the biofiltration basin needs to drawdown in a 48 hour time period. The media will be Media Mix C, which is mostly sand resulting in a difference between the media wilting point and field capacity of 0.11 cubic feet per cubic foot and a difference between the media porosity and field capacity of 0.26 cubic feet per cubic foot. The P content of the media is less than 30 mg/kg (milligrams per kilogram) and no soil amendments will be used to attenuate phosphorus. The following steps detail how this system would be set up in the MIDS calculator.

Step 1: Determine the watershed characteristics of your entire site. For this example we have a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious area in type B soils. The pervious area includes the turf area and the area of the biofiltration basin.

Step 2: Fill in the site specific information into the Site Information tab. This includes entering a ZIP Code (55414 for this example) and the watershed information from Step 1. The Managed turf area includes the turf area and the area of the bioretention basin. ZIP code and impervious area must be filled in or an error message will be generated. Other fields on this screen are optional.

Step 3: Go to the Schematic tab and drag and drop the Bioretention basin (with underdrain) icon into the Schematic window.

Step 4: Open the BMP properties for the bioretention basin by right clicking on the Bioretention basin (with underdrain) icon and selecting Edit BMP Properties, or by double clicking on the Bioretention basin (with underdrain) icon.

Step 5: If help is needed click on the Minnesota Stormwater Manual Wiki link or the Help button to review input parameter specifications and calculations specific to the Bioretention basin (with underdrain) BMP.

Step 6: Determine the watershed characteristics for the Bioretention basin. For this example the entire site is draining to the bioretention basin. The watershed parameters therefore include a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. There is no routing for this BMP. Fill in the BMP specific watershed information in the Watershed tab (1.4 acres on impervious cover and 0.8 acres of Managed turf in B soils).

Step 7: Enter the BMP design parameters into the BMP parameters tab. This bioretention basin with an elevated underdrain example would require the following entries:

  • Is the underdrain elevated above native soils – Yes;
  • Are the sides of the basin lined with an impermeable liner – No;
  • Is the bottom of the basin lined with an impermeable liner – No;
  • Surface area at overflow [AO]: 6534 square feet;
  • Media surface area [AM]: 5600 square feet;
  • Surface area at underdrain [AU]: 3948 square feet;
  • Bottom surface area (area at media-soil interface) [AB]: 3230 square feet;
  • Overflow depth [DO]: 1 foot;
  • Total media depth [DM]: 3 feet;
  • Depth below underdrain [DU]: 1 foot;
  • Media field capacity minus wilting point [FP-WP]: 0.11 cubic feet per cubic foot;
  • Media porosity minus field capacity [n-FC]: 0.26 cubic feet per cubic foot;
  • Is a tree(s) planted in the BMP – No;
  • Bioretention planting media mix – Media Mix C (selected in dropdown box);
  • Is the P content of the media less than 30 mg/kg – autofills to “Yes” for Media Mix C;
  • Is there a designed phosphorus treatment layer – No;
  • Underlying soil – Hydrologic Soil Group: SM (HSG B; 0.45 in/hr) (selected in dropdown box); and
  • Required drawdown time: 48 hours (selected in dropdown box).

Step 8: Click on BMP Summary tab to view results for this BMP.

Step 9: Click on the OK button to exit the BMP Properties screen.

Step 10: Click on Results tab to see overall results for the site.

Biofiltration Basin with an underdrain at bottom example (Version 2)

Schematic used for example bioretention with underdrain at the bottom
Schematic used for MIDS calculator example for bioretention with an underdrain at the bottom. In this example there is 1.4 acres of impervious parking draining to the bioretention basin. Pervious area is 0.8 acres and includes the turf area and the bioretention BMP. See Step 1.
screen shot Site Information tab with underdrain at the bottom
Screen shot of the Site Information tab for the MIDS example for bioretention with an underdrain at the bottom. The user must input impervious acres and ZIP code. Other fields are optional. See Step 2.
Schematic used for example bioretention with underdrain at the bottom.
Schematic used for the MIDS calculator example for bioretention with an underdrain at the bottom. See Step 1.
Screen shot of Schematic tab for bioretention with underdrain at the bottom example
Screen shot of the Schematic tab for the MIDS calculator example for bioretention with an underdrain at the bottom. See Step 3.

An unlined biofiltration basin with an underdrain at the bottom is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area (turf area and the bioretention BMP area). All of the runoff from the watershed will be treated by the biofiltration basin. The soils across the area have a unified soils classification of SM (HSG type B soil). The surface overflow is located 1 ft above the media surface. The surface area of the biofiltration basin at the overflow point will be 6534 square feet. The area is 5600 square feet at the media surface. The area at the media-soil interface is 3320 square feet. The total media depth will be 3 feet. The media will be Media Mix C, which is mostly sand resulting in a difference between the media wilting point and field capacity of 0.11 cubic feet per cubic foot and a difference between the media porosity and field capacity of 0.26 cubic feet per cubic foot. The P content of the media is less than 30 mg/kg (milligrams per kilogram) and no soil amendments will be used to attenuate phosphorus. The following steps detail how this system would be set up in the MIDS calculator.

Step 1: Determine the watershed characteristics of your entire site. For this example we have a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious area in type B soils. The pervious area includes the turf area and the area of the biofiltration basin.

Step 2: Fill in the site specific information into the Site Information tab. This includes entering a Zip Code (55414 for this example) and the watershed information from Step 1. The Managed turf area includes the turf area and the area of the bioretention basin. Zip code and impervious area must be filled in or an error message will be generated. Other fields on this screen are optional.

Step 3: Go to the Schematic tab and drag and drop the Bioretention basin (with underdrain) icon into the Schematic window.

Step 4: Open the BMP properties for the bioretention basin by right clicking on the “Bioretention basin (with underdrain)” icon and selecting Edit BMP Properties, or by double clicking on the Bioretention basin (with underdrain) icon.

Step 5: If help is needed click on the Minnesota Stormwater Manual Wiki link or the Help button to review input parameter specifications and calculations pertinent to the “Bioretention basin (with underdrain)” BMP.

Step 6: Determine the watershed characteristics for the biofiltration basin. For this example the entire site is draining to the biofiltration basin. The watershed parameters therefore include a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. There is no routing for this BMP. Fill in the BMP specific watershed information in the Watershed tab (1.4 acres on impervious cover and 0.8 acres of Managed turf in B soils).

Step 7: Enter in the BMP design parameters into the BMP Parameters tab. This bioretention basin example with an underdrain at the bottom of the media requires the following entries:

  • Is the underdrain elevated above native soils – No;
  • Are the sides of the basin lined with an impermeable liner – No;
  • Is the bottom of the basin lined with an impermeable liner – No;
  • Surface area of overflow [AO]: 6534 square feet;
  • Media surface area [AM]: 5600 square feet;
  • Bottom surface area (area at media-soil interface) [AB]: 3230 square feet;
  • Overflow depth [DO]: 1 foot;
  • Total media depth [DM]: 3 feet;
  • Media field capacity minus wilting point [FC-WP]: 0.11 cubic feet per cubic foot;
  • Media porosity minus field capacity [n-FC]: 0.26 cubic feet per cubic foot;
  • Is a tree(s) planted in the BMP – No;
  • Bioretention planting media mix – Media Mix C (selected from the dropdown box);
  • Is the P content of the media less than 30 mg/kg – autofills to “Yes” for Media Mix C;
  • Is a soil amendment used to attenuate phosphorus– No;
  • Underlying soil – Hydrologic Soil Group: SM (HSG B; 0.45 in/hr) (selected from the dropdown box); and
  • Required drawdown time: 48 hrs (selected from the dropdown box).

Step 8: Click on BMP Summary tab to view results for this BMP.

Step 9: Click on the OK button to exit the BMP properties screen.

Step 10: Click on Results tab to see overall results for the site.

Requirements

image illustrating separation distance to bedrock or seasonal high water table
Measurement of depth from the bottom of the infiltration BMP (bioretention with elevated underdrain) to the seasonally high water table or bedrock. Note that there must be a minimum of 2 feet separation when soils beneath the BMP are ripped, with a total separation distance of 3 feet or more. Infiltration BMPs include any BMP that allows water to infiltrate into the underlying soil.
Warning: The following are requirements of the Minnesota Construction Stormwater General Permit
  • At least a 3 foot separation from the bottom of an infiltration system (includes bioretention with elevated underdrain) to the seasonal high water table
  • If soils below the bottom of the infiltration system are ripped to promote infiltration, at least 2 feet of separation from the bottom of the ripped zone to the seasonal high water table
  • Use the most restrictive infiltration rate within 5 feet of the bottom of the BMP
  • For measured infiltration rates, apply a safety factor of 2
  • Pretreatment for infiltration systems

Recommendations

Caution: The following are recommendations for inputs into the MIDS Calculator

Information

Information: The following information may be useful in determining inputs for the MIDS Calculator

Links to MIDS pages


Related pages

This page was last edited on 29 January 2023, at 13:27.