m |
m |
||
(17 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | <font size=3>'''Stormwater BMP selection in karst settings. Sources Karst Working Group, 2009; Minnesota Stormwater Wiki; Tennessee Permanent Stormwater Management and Design Guidance.'''</font size><br> | |
− | Link to this [[Structural BMP use in karst settings|table]] | + | Link to this [[Structural BMP use in karst settings|table]] |
<table class="sortable"> | <table class="sortable"> | ||
<tr> | <tr> | ||
<th>'''BMP'''</th> | <th>'''BMP'''</th> | ||
+ | <th>Suitability in karst regions</th> | ||
<th>'''Karst considerations'''</th> | <th>'''Karst considerations'''</th> | ||
+ | <th>[https://stormwater.pca.state.mn.us/index.php?title=MN_CSW_Permit_Section_16_Infiltration_Systems Construction stormwater permit restriction<sup>1</sup>]</th> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>Bioretention</td> | + | <td>Impervious area disconnect</td> |
− | <td>If | + | <td>Preferred</td> |
+ | <td> | ||
+ | *Strongly recommended for most residential lots less than 6,000 square feet. | ||
+ | *Discharge point from the disconnect should extend at least 15 feet from any building foundation. | ||
+ | </td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Bioretention with underdrain (biofiltration)</td> | ||
+ | <td>Preferred</td> | ||
+ | <td> | ||
+ | *Requires 3 foot minimum separation distance between practice bottom and bedrock. If this is not possible, an underdrain should be used to convey the water away. | ||
+ | *It’s recommended that the drainage area to an individual bioretention BMP be kept less than 20,000 square feet. | ||
+ | *Larger designs that rely on exfiltration of treated runoff into the soils below are not recommended. | ||
+ | </td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Rain tank/cistern</td> | ||
+ | <td>Preferred</td> | ||
+ | <td> | ||
+ | *Above ground tanks are preferred to below ground. | ||
+ | *Overflow of tank should extend at least 15 feet from building foundation. | ||
+ | </td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Rooftop disconnect</td> | ||
+ | <td>Preferred</td> | ||
+ | <td> | ||
+ | *15 feet foundation set back. | ||
+ | *Runoff should be spread diffusely across landscape. | ||
+ | </td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Green roofs</td> | ||
+ | <td>Preferred</td> | ||
+ | <td> | ||
+ | *Runoff should be spread diffusely across landscape.</td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Dry swale or grassed channel</td> | ||
+ | <td>Preferred</td> | ||
+ | <td> | ||
+ | *Line with underdrains. | ||
+ | *Incorporate compost amendments into the bottom of the channel to improve runoff reduction for vegetative uptake, and transpiration. | ||
+ | *Do not incorporate check dams unless the swale or channel incorporates an underdrain. Otherwise small areas of infiltration would develop in the zones upgradient of the check dam where the water is captured without adequate outlet. | ||
+ | {{alert|If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst|alert-danger}} | ||
+ | </td> | ||
+ | <td>Yes if designed for infiltration</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Media filter</td> | <td>Media filter</td> | ||
− | <td> | + | <td>Preferred</td> |
+ | <td> | ||
+ | *Recommended practice in areas of shallow bedrock and soil.</td> | ||
+ | <td>No</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Vegetative filter</td> | <td>Vegetative filter</td> | ||
+ | <td>Preferred</td> | ||
+ | <td> | ||
+ | *Recommended practice in areas of shallow bedrock and soil.</td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Soil compost amendment</td> | ||
+ | <td>Adequate</td> | ||
+ | <td></td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Small scale infiltration/micro-bioinfiltration</td> | ||
+ | <td>Adequate</td> | ||
<td> | <td> | ||
− | * | + | *Create multiple small sized infiltration BMPs to infiltrate impervious areas of 250 to 2,500 square feet. |
− | * | + | *Not recommended for sites identified as a stormwater hotspot. |
+ | {{alert|If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst|alert-danger}} | ||
+ | </td> | ||
+ | <td>Yes</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Permeable pavement</td> | ||
+ | <td>Adequate</td> | ||
+ | <td>{{alert|If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst|alert-danger}}</td> | ||
+ | <td>Yes if designed for infiltration (no underdrain)</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Infiltration trench or basin</td> | <td>Infiltration trench or basin</td> | ||
+ | <td>Adequate</td> | ||
<td> | <td> | ||
− | * | + | *Surface area to depth ratios of practices may need to be larger than typical basin designs to minimize depth of the BMP. |
− | * | + | *Confirm suitability with supporting geotechnical investigations and calculations. |
− | + | *Not recommended for sites identified as a stormwater hotspot. | |
+ | *Incorporate pre-treatment to limit risk of groundwater contamination in the event of future failure of the BMP associated with development of a karst feature. Local review authority should be consulted for approval. | ||
+ | {{alert|If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst|alert-danger}} | ||
+ | </td> | ||
+ | <td>Yes</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>Constructed wetlands</td> |
+ | <td>Adequate</td> | ||
+ | <td> | ||
+ | *Requires larger surface area to drainage area ratios to limit the depth of the wetland. | ||
+ | *Bedrock should act like a liner and help to maintain a permanent pool, unless fracture zone is present. | ||
+ | *Consider using [http://stormwater.pca.state.mn.us/index.php/Liners_for_stormwater_management liner and liner cells]. | ||
+ | {{alert|If the CSW permit applies, liners are required in areas of active karst|alert-danger}} | ||
+ | </td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Dry extended detention (ED) ponds and wet ponds</td> | ||
+ | <td>Adequate</td> | ||
<td> | <td> | ||
− | * | + | *Requires larger surface area to drainage area ratios to limit the depth of the basin or pond. If analysis shows that the soils can support the weight of a pond then a [http://stormwater.pca.state.mn.us/index.php/Liners_for_stormwater_management liner] should be used to prevent infiltration |
− | + | {{alert|If the CSW permit applies, liners are required in areas of active karst|alert-danger}}</td> | |
− | + | <td>No</td> | |
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>Wet swale</td> |
+ | <td>Discouraged</td> | ||
+ | <td>Not feasible</td> | ||
+ | <td>No</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Large scale infiltration</td> | ||
+ | <td>Discouraged</td> | ||
<td> | <td> | ||
− | * | + | *Use small scale infiltration practices instead. |
− | + | {{alert|If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst|alert-danger}} | |
− | + | </td> | |
+ | <td>Yes</td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <font size=1><sup>1</sup>[https://stormwater.pca.state.mn.us/index.php?title=MN_CSW_Permit_Section_16_Infiltration_Systems#16.20 Section 16.20 of the CSW Permit] prohibits prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of [[Karst|active karst features]].</font size> | ||
+ | |||
+ | <noinclude> | ||
+ | [[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Hydrology and geology]] | ||
+ | </noinclude> |
Stormwater BMP selection in karst settings. Sources Karst Working Group, 2009; Minnesota Stormwater Wiki; Tennessee Permanent Stormwater Management and Design Guidance.
Link to this table
BMP | Suitability in karst regions | Karst considerations | Construction stormwater permit restriction1 |
---|---|---|---|
Impervious area disconnect | Preferred |
|
No |
Bioretention with underdrain (biofiltration) | Preferred |
|
No |
Rain tank/cistern | Preferred |
|
No |
Rooftop disconnect | Preferred |
|
No |
Green roofs | Preferred |
|
No |
Dry swale or grassed channel | Preferred |
Warning: If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst
|
Yes if designed for infiltration |
Media filter | Preferred |
|
No |
Vegetative filter | Preferred |
|
No |
Soil compost amendment | Adequate | No | |
Small scale infiltration/micro-bioinfiltration | Adequate |
Warning: If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst
|
Yes |
Permeable pavement | Adequate | Warning: If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst |
Yes if designed for infiltration (no underdrain) |
Infiltration trench or basin | Adequate |
Warning: If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst
|
Yes |
Constructed wetlands | Adequate |
Warning: If the CSW permit applies, liners are required in areas of active karst
|
No |
Dry extended detention (ED) ponds and wet ponds | Adequate |
Warning: If the CSW permit applies, liners are required in areas of active karst |
No |
Wet swale | Discouraged | Not feasible | No |
Large scale infiltration | Discouraged |
Warning: If the CSW permit applies, Section 16.20 prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst
|
Yes |
1Section 16.20 of the CSW Permit prohibits prohibits permittees from constructing infiltration systems in areas within 1,000 feet upgradient or 100 feet downgradient of active karst features.
This page was last edited on 13 December 2022, at 18:23.