(Created page with "<center><font size=3>'''Water harvesting and use system matrix'''</font size><br> Link to this table</center> <table class="sorta...") |
m |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | <font size=3>'''Water harvesting and use system matrix'''</font size><br> | |
− | + | Link to this [[Water harvesting and use system matrix|table]] | |
− | Link to this [[Water harvesting and use system | ||
<table class="sortable"> | <table class="sortable"> | ||
Line 111: | Line 110: | ||
<font size=1><sup>1</sup>Minimal - pretreatment; Medium - pretreatment + disinfection OR pretreatment + treatment; High - pretreatment + treatment + disinfection</font size> | <font size=1><sup>1</sup>Minimal - pretreatment; Medium - pretreatment + disinfection OR pretreatment + treatment; High - pretreatment + treatment + disinfection</font size> | ||
− | [[ | + | <noinclude> |
+ | [[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Harvest and reuse]] | ||
+ | </noinclude> |
Water harvesting and use system matrix
Link to this table
Beneficial Uses | |||||
---|---|---|---|---|---|
Health criteria Level | Level of effort1 | Health criteria Level | Level of effort1 | ||
Outdoor | Sanitary sewer flushing | Limited human exposure at point of use and limited exposure to pathogens upstream of point of use | No treatment needed | Limited human exposure at point of use and limited exposure to pathogens upstream of point of use | Minimal |
Irrigation – low exposure risk | Limited human exposure at point of use and limited exposure to pathogens upstream of point of use | Minimal | Limited human exposure at point of use and limited exposure to pathogens upstream of point of use | Minimal to Medium | |
Irrigation – high exposure risk | Limited human contact and controlled access at point of use | Minimal to Medium | Limited human contact and controlled access at point of use | Medium to High | |
Vehicle/building washing | Limited human contact and controlled access at point of use | Minimal to Medium | Limited human contact and controlled access at point of use | Minimal to Medium | |
Fire fighting | Limited human exposure at point of use and limited exposure to pathogens upstream of point of use | Minimal | Limited human exposure at point of use and limited exposure to pathogens upstream of point of use | Minimal to Medium | |
Water features (uncontrolled access) | Limited human contact and controlled access at point of use | Medium | Limited human contact and controlled access at point of use | Medium | |
Street cleaning/ dust control | Limited human contact and controlled access at point of use | Minimal to Medium | Limited human contact and controlled access at point of use | Minimal to Medium | |
Indoor | Fire supression | Limited human contact and controlled access at point of use | Medium | Limited human contact and controlled access at point of use | Medium |
Cooling | Limited human contact and controlled access at point of use | Minimal to Medium | Limited human contact and controlled access at point of use | Minimal to High | |
Process /Boiler Water | Limited human contact and controlled access at point of use | Minimal to Medium | Limited human contact and controlled access at point of use | Minimal to High | |
Flushing | Uncontrolled access at point of use | Minimal to Medium | Uncontrolled access at point of use | Medium to High | |
Washing | Uncontrolled access at point of use | Medium | Uncontrolled access at point of use | Medium to High | |
Drinking water | Drinking water standards | Drinking water standards | Drinking water standards | Drinking water standards |
1Minimal - pretreatment; Medium - pretreatment + disinfection OR pretreatment + treatment; High - pretreatment + treatment + disinfection