(Created page with "<center><font size=3>'''Erosion Control Technology Council standard specifications for erosion control blankets and mulch control nets'''</font size><br> Link to this Erosi...")
 
m
 
(9 intermediate revisions by 2 users not shown)
Line 1: Line 1:
<center><font size=3>'''Erosion Control Technology Council standard specifications for erosion control blankets and mulch control nets'''</font size><br>
+
<font size=3>'''Erosion Control Technology Council standard specifications for erosion control blankets and mulch control nets'''</font size><br>
 
+
Link to this [[Erosion Control Technology Council standard specifications for erosion control blankets and mulch control nets|table]]
Link to this [[Erosion Control Technology Council standard specifications for erosion control blankets and mulch control nets|table]]</center>
 
  
 
<table class="sortable">
 
<table class="sortable">
 
<tr>
 
<tr>
<th colspan=7>ULTRA SHORT-TERM - Typical 3 month functional longevity</th>
+
<th rowspan=2>Type</th>
</tr>
 
 
 
<tr>
 
<th>Type</th>
 
 
<th rowspan=2>Product Description</th>
 
<th rowspan=2>Product Description</th>
 
<th rowspan=2>Material Composition</th>
 
<th rowspan=2>Material Composition</th>
<th>Slope Applications*</th>
+
<th colspan=2>Slope Applications*</th>
 
<th>Channel Applications*</th>
 
<th>Channel Applications*</th>
 
<th rowspan=2>Minimum Tensile Strength 1</th>
 
<th rowspan=2>Minimum Tensile Strength 1</th>
 
</tr>
 
</tr>
 
 
<tr>
 
<tr>
 
<th>Maximum  Gradient</th>
 
<th>Maximum  Gradient</th>
Line 22: Line 16:
 
<th>Permissible Shear Stresss <sup>3, 4, 6</sup></th>
 
<th>Permissible Shear Stresss <sup>3, 4, 6</sup></th>
 
</tr>
 
</tr>
 
+
<tr>
 
+
<td colspan=7>'''ULTRA SHORT-TERM - Typical 3 month functional longevity'''</td>
 
+
</tr>
 
<tr>
 
<tr>
 
<td>1.A</td>
 
<td>1.A</td>
Line 34: Line 28:
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>1.B</td>
 
<td>1.B</td>
Line 46: Line 37:
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>1.C</td>
 
<td>1.C</td>
Line 58: Line 46:
 
<td>50 lbs/ft (0.73 kN/m)</td>
 
<td>50 lbs/ft (0.73 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>1.D</td>
 
<td>1.D</td>
Line 70: Line 55:
 
<td>75 lbs/ft (1.09 kN/m)</td>
 
<td>75 lbs/ft (1.09 kN/m)</td>
 
</tr>
 
</tr>
 
 
<tr>
 
<tr>
<th colspan=7>SHORT-TERM - Typical 12 month functional longevity</th>
+
<td colspan=7>'''SHORT-TERM - Typical 12 month functional longevity'''</td>
 
</tr>
 
</tr>
 
 
 
<tr>
 
<tr>
 
<td>2.A</td>
 
<td>2.A</td>
Line 85: Line 67:
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>2.B</td>
 
<td>2.B</td>
Line 97: Line 76:
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
<td>5 lbs/ft (0.073 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>2.C</td>
 
<td>2.C</td>
Line 109: Line 85:
 
<td>50 lbs/ft (0.73 kN/m)</td>
 
<td>50 lbs/ft (0.73 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>2.D</td>
 
<td>2.D</td>
Line 121: Line 94:
 
<td>75 lbs/ft (1.09 kN/m)</td>
 
<td>75 lbs/ft (1.09 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
<tr>
 
<tr>
<th colspan=7>EXTENDED-TERM - Typical 24 month functional longevity</th>
+
<td colspan=7>'''EXTENDED-TERM - Typical 24 month functional longevity'''</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>3.A</td>
 
<td>3.A</td>
Line 138: Line 106:
 
<td>25 lbs/ft (0.36 kN/m)</td>
 
<td>25 lbs/ft (0.36 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>3.B</td>
 
<td>3.B</td>
Line 150: Line 115:
 
<td>100 lbs/ft (1.45 kN/m)</td>
 
<td>100 lbs/ft (1.45 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
<tr>
 
<tr>
<th colspan=7>LONG-TERM - Typical 36 month functional longevity</th>
+
<td colspan=7>'''LONG-TERM - Typical 36 month functional longevity'''</td>
 
</tr>
 
</tr>
 
 
 
 
<tr>
 
<tr>
 
<td>4</td>
 
<td>4</td>
Line 167: Line 127:
 
<td>125 lbs/ft (1.82 kN/m)</td>
 
<td>125 lbs/ft (1.82 kN/m)</td>
 
</tr>
 
</tr>
 
 
 
 
 
 
</table>
 
</table>
 +
<font size=1>
 +
<sup>*</sup> [http://www.iwr.msu.edu/rusle/cfactor.htm C factor] and shear stress for [https://www.ectc.org/assets/docs/RECPDocs/ectc_july2017_recpspecification%20final.pdf Types 1.A., 2.A. and 3.A mulch control nettings] must be obtained with netting used in conjunction with pre-applied mulch material.<br>
 +
<sup>1</sup> Minimum Average Roll Values when tested in the machine direction using ECTC Modified ASTM D 5035.<br>
 +
<sup>2</sup> C Factor calculated as ratio of soil loss from RECP (rolled erosion control product) protected slope (tested at specified or greater gradient, h:v) to ratio of soil loss from unprotected (control) plot in large-scale testing. These performance test values should be *supported by periodic bench scale testing under similar test conditions using [http://applications.roadauthority.com/Standards/?Id=35413B9C-6E61-4E21-BA56-6FA7618E65E8 ECTC Test Method # 2].<br>
 +
<sup>3</sup> Minimum shear stress RECP (unvegetated) can sustain without physical damage or excess erosion > 12.7 mm(0.5 in) soil loss] during a 30-minute flow event in large-scale testing. These performance test values should be *supported by periodic bench scale testing under similar test conditions and failure criteria using ECTC Test Method #3.<br>
 +
<sup>4</sup> The permissible shear stress levels established for each performance category are based on historical experience with products characterized by Manning's roughness coefficients in the range of 0.01 - 0.05.<br>
 +
<sup>5</sup> Acceptable large-scale test methods may include [https://www.astm.org/ ASTM D6459] or other independent testing deemed acceptable by the engineer.<br>
 +
<sup>6</sup>Acceptable large-scale testing protocol may include [https://www.astm.org/ ASTM D6460] or other independent testing deemed acceptable by the engineer.</font size>
  
Notes: 
+
<noinclude>
<sup>*</sup> C factor and shear stress for Types 1.A., 2.A. and 3.A mulch control nettings must be obtained with netting used in conjunction with preapplied mulch material.
+
[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Erosion prevention]]
<sup>1</sup> Minimum Average Roll Values when tested in the machine direction using ECTC Modified ASTM D 5035.
+
</noinclude>
<sup>2</sup> C Factor calculated as ratio of soil loss from RECP protected slope (tested at specified or greater gradient, h:v) to ratio of soil loss from unprotected (control) plot in large-scale testing. These performance test values should be supported by periodic bench scale testing under similar test conditions using ECTC Test Method # 2.
 
<sup>3</sup> Minimum shear stress RECP (unvegetated) can sustain without physical damage or excess erosion [> 12.7 mm(0.5 in) soil loss] during a 30-minute flow event in large-scale testing. These performance test values should be supported by periodic bench scale testing under similar test conditions and failure criteria using ECTC Test Method #3.
 
<sup>4</sup> The permissible shear stress levels established for each performance category are based on historical experience with products characterized by Manning's roughness coefficients in the range of 0.01 - 0.05.
 
<sup>5</sup> Acceptable large-scale test methods may include ASTM D6459 or other independent testing deemed acceptable by the engineer.
 
<sup>6</sup>Acceptable large-scale testing protocol may include ASTM D6460 or other independent testing deemed acceptable by the engineer.
 
 
 
 
 
 
 
 
 
[[category:Table]]
 

Latest revision as of 21:44, 22 December 2022

Erosion Control Technology Council standard specifications for erosion control blankets and mulch control nets
Link to this table

Type Product Description Material Composition Slope Applications* Channel Applications* Minimum Tensile Strength 1
Maximum Gradient C Factor 2, 5 Permissible Shear Stresss 3, 4, 6
ULTRA SHORT-TERM - Typical 3 month functional longevity
1.A Mulch Control Nets A photodegradable synthetic mesh or woven biodegradable natural fiber netting. 5:1 (H:V) < 0.10 @ 5:1 = 0.25 lbs/ft2 (12 Pa) 5 lbs/ft (0.073 kN/m)
1.B Netless Rolled Erosion Control Blankets Natural and/or polymer fibers mechanically interlocked and/or chemically adhered together to form a RECP. 4:1 (H:V) < 0.10 @ 4:1 = 0.5 lbs/ft2 (24 Pa) 5 lbs/ft (0.073 kN/m)
1.C Single-net Erosion Control Blankets & Open Weave Textiles Processed degradable natural and/or polymer fibers mechanically bound together by a single rapidly degrading, synthetic or natural fiber netting or an open weave textile of processed rapidly degrading natural or polymer yarns or twines woven into a continuous matrix. 3:1 (H:V) < 0.15 @ 3:1 = 1.5 lbs/ft2 (72 Pa) 50 lbs/ft (0.73 kN/m)
1.D Double-net Erosion Control Blankets Processed degradable natural and/or polymer fibers mechanically bound together between two rapidly degrading, synthetic or natural fiber nettings. 2:1 (H:V) < 0.20 @ 2:1 = 1.75 lbs/ft2 (84 Pa) 75 lbs/ft (1.09 kN/m)
SHORT-TERM - Typical 12 month functional longevity
2.A Mulch Control Nets A photodegradable synthetic mesh or woven biodegradable natural fiber netting. 5:1 (H:V) < 0.10 @ 5:1 = 0.25 lbs/ft2 (12 Pa) 5 lbs/ft (0.073 kN/m)
2.B Netless Rolled Erosion Control Blankets Natural and/or polymer fibers mechanically interlocked and/or chemically adhered together to form a RECP. 4:1 (H:V) < 0.10 @ 4:1 = 0.5 lbs/ft2 (24 Pa) 5 lbs/ft (0.073 kN/m)
2.C Single-net Erosion Control Blankets & Open Weave Textiles An erosion control blanket composed of processed degradable natural or polymer fibers mechanically bound together by a single degradable synthetic or natural fiber netting to form a continuous matrix or an open weave textile composed of processed degradable natural or polymer yarns or twines woven into a continuous matrix. 3:1 (H:V) < 0.15 @ 3:1 = 1.5 lbs/ft2 (72 Pa) 50 lbs/ft (0.73 kN/m)
2.D Double net Erosion Control Blankets Processed degradable natural and/or polymer fibers mechanically bound together between two degradable, synthetic or natural fiber nettings. 2:1 (H:V) < 0.20 @ 2:1 = 1.75 lbs/ft2 (84 Pa) 75 lbs/ft (1.09 kN/m)
EXTENDED-TERM - Typical 24 month functional longevity
3.A Mulch Control Nets A slow degrading synthetic mesh or woven natural fiber netting. 5:1 (H:V) < 0.10 @ 5:1 = 0.25 lbs/ft2 (12 Pa) 25 lbs/ft (0.36 kN/m)
3.B Erosion Control Blankets & Open Weave Textiles An erosion control blanket composed of processed slow degrading natural or polymer fibers mechanically bound together between two slow degrading synthetic or natural fiber nettings to form a continuous matrix or an open weave textile composed of processed slow degrading natural or polymer yarns or twines woven into a continuous matrix. 1.5:1 (H:V) < 0.25 @ 1.5:1 = 2.00 lbs/ft2 (96 Pa) 100 lbs/ft (1.45 kN/m)
LONG-TERM - Typical 36 month functional longevity
4 Erosion Control Blankets & Open Weave Textiles An erosion control blanket composed of processed slow degrading natural or polymer fibers mechanically bound together between two slow degrading synthetic or natural fiber nettings to form a continuous matrix or an open weave textile composed of processed slow degrading natural or polymer yarns or twines woven into a continuous matrix. 1:1 (H:V) < 0.25 @ 1:1 = 2.25 lbs/ft2 (108 Pa) 125 lbs/ft (1.82 kN/m)

* C factor and shear stress for Types 1.A., 2.A. and 3.A mulch control nettings must be obtained with netting used in conjunction with pre-applied mulch material.
1 Minimum Average Roll Values when tested in the machine direction using ECTC Modified ASTM D 5035.
2 C Factor calculated as ratio of soil loss from RECP (rolled erosion control product) protected slope (tested at specified or greater gradient, h:v) to ratio of soil loss from unprotected (control) plot in large-scale testing. These performance test values should be *supported by periodic bench scale testing under similar test conditions using ECTC Test Method # 2.
3 Minimum shear stress RECP (unvegetated) can sustain without physical damage or excess erosion > 12.7 mm(0.5 in) soil loss] during a 30-minute flow event in large-scale testing. These performance test values should be *supported by periodic bench scale testing under similar test conditions and failure criteria using ECTC Test Method #3.
4 The permissible shear stress levels established for each performance category are based on historical experience with products characterized by Manning's roughness coefficients in the range of 0.01 - 0.05.
5 Acceptable large-scale test methods may include ASTM D6459 or other independent testing deemed acceptable by the engineer.
6Acceptable large-scale testing protocol may include ASTM D6460 or other independent testing deemed acceptable by the engineer.