m |
m |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 8: | Line 8: | ||
<th>O & M Considerations</th> | <th>O & M Considerations</th> | ||
</tr> | </tr> | ||
− | |||
<tr> | <tr> | ||
<th colspan=3>Human Health Risks</th> | <th colspan=3>Human Health Risks</th> | ||
</tr> | </tr> | ||
− | |||
− | |||
<tr> | <tr> | ||
<td>Source area pollutants</td> | <td>Source area pollutants</td> | ||
Line 26: | Line 23: | ||
</td> | </td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Hazardous spills in the source area, including sudden air releases of hazardous substances that could deposit in the collection and storage systems</td> | <td>Hazardous spills in the source area, including sudden air releases of hazardous substances that could deposit in the collection and storage systems</td> | ||
<td> | <td> | ||
− | *Incorporate at least a 72-hour residence time of harvested stormwater in storage unit to contain hazardous spills in the source area prior to distribution | + | *Incorporate at least a 72-hour residence time of harvested stormwater in storage unit to contain hazardous spills in the source area prior to distribution |
*Incorporate an emergency bypass in the collection system | *Incorporate an emergency bypass in the collection system | ||
</td> | </td> | ||
Line 41: | Line 35: | ||
</td> | </td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Metals and other chemicals from roofing materials (link to table 4 in WQ considerations) </td> | <td>Metals and other chemicals from roofing materials (link to table 4 in WQ considerations) </td> | ||
Line 51: | Line 42: | ||
*Regular inspection and cleaning of system components to prevent degradation</td> | *Regular inspection and cleaning of system components to prevent degradation</td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Bacteria, viruses</td> | <td>Bacteria, viruses</td> | ||
Line 66: | Line 54: | ||
</td> | </td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Mosquito and other vector-borne illnesses</td> | <td>Mosquito and other vector-borne illnesses</td> | ||
Line 74: | Line 59: | ||
*Install insect screens on exposed pipe and other openings | *Install insect screens on exposed pipe and other openings | ||
*See the following websites for information on mosquito control in storage ponds: | *See the following websites for information on mosquito control in storage ponds: | ||
− | **[http://ipm.ucanr.edu/PMG/PESTNOTES/mosquitostormwater5.html UC-IPM | + | **[http://ipm.ucanr.edu/PMG/PESTNOTES/mosquitostormwater5.html UC-IPM] |
**[http://stormwater.pca.state.mn.us/index.php/Mosquito_control_and_stormwater_management MPCA] | **[http://stormwater.pca.state.mn.us/index.php/Mosquito_control_and_stormwater_management MPCA] | ||
</td> | </td> | ||
Line 82: | Line 67: | ||
</td> | </td> | ||
</tr> | </tr> | ||
− | |||
− | |||
<tr> | <tr> | ||
<th colspan=3>Ecological Risks</th> | <th colspan=3>Ecological Risks</th> | ||
</tr> | </tr> | ||
− | |||
− | |||
<tr> | <tr> | ||
<td>Plant communities</td> | <td>Plant communities</td> | ||
Line 99: | Line 80: | ||
*Irrigation rates that optimize the saturation of soils without interfering with plant growth. </td> | *Irrigation rates that optimize the saturation of soils without interfering with plant growth. </td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Soils</td> | <td>Soils</td> | ||
Line 109: | Line 87: | ||
*Regular monitoring of stormwater runoff and soil quality if salt contamination of soils is a concern </td> | *Regular monitoring of stormwater runoff and soil quality if salt contamination of soils is a concern </td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Aquatic ecosystems</td> | <td>Aquatic ecosystems</td> | ||
Line 122: | Line 97: | ||
*Regular monitoring of storage pond for adverse ecological impacts</td> | *Regular monitoring of storage pond for adverse ecological impacts</td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Local hydrology</td> | <td>Local hydrology</td> | ||
Line 132: | Line 104: | ||
*Regular inspection and maintenance of storage, overflow and distribution system components</td> | *Regular inspection and maintenance of storage, overflow and distribution system components</td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Equipment degradation</td> | <td>Equipment degradation</td> | ||
Line 144: | Line 113: | ||
*Regular inspection and cleaning of system components</td> | *Regular inspection and cleaning of system components</td> | ||
</tr> | </tr> | ||
− | |||
− | |||
− | |||
</table> | </table> | ||
− | + | <noinclude>[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Harvest and reuse]]</noinclude> | |
− | |||
− | |||
− | |||
− | [[ |
Elements of design, operation, and maintenance that address potential risks associated with stormwater harvesting and use
Link to this table
Risk Type | Design Considerations | O & M Considerations |
---|---|---|
Human Health Risks | ||
Source area pollutants |
|
|
Hazardous spills in the source area, including sudden air releases of hazardous substances that could deposit in the collection and storage systems |
|
|
Metals and other chemicals from roofing materials (link to table 4 in WQ considerations) |
|
|
Bacteria, viruses |
|
|
Mosquito and other vector-borne illnesses |
|
|
Ecological Risks | ||
Plant communities |
|
|
Soils |
|
|
Aquatic ecosystems |
|
|
Local hydrology |
|
|
Equipment degradation |
|
|
This page was last edited on 3 August 2022, at 19:53.