m (→Related pages) |
|||
(11 intermediate revisions by the same user not shown) | |||
Line 8: | Line 8: | ||
==Changes to Version 4 of the MIDS Calculator== | ==Changes to Version 4 of the MIDS Calculator== | ||
− | {{alert| | + | {{alert|Updates have been made to Version 4 of the MIDS Calculator|alert-info}} |
+ | *'''The USER must enter a bypass percent for this BMP.''' [https://stormwater.pca.state.mn.us/index.php?title=Estimating_and_calculating_bypass_for_the_Minimal_Impact_Design_Standards_(MIDS)_Calculator See the guidance for determining bypass percent.] | ||
*Users can specify a constructed stormwater pond with an iron-enhanced filtration bench to allow dissolved phosphorus removal. To achieve this, the user is asked whether amendments have been incorporated into the pond design. The user answers yes or no. If the user answers "No", there is no removal of dissolved phosphorus. If the user answers "Yes", phosphorus removal is 40 percent of the influent dissolved phosphorus. This removal value is not affected by the pond design level. | *Users can specify a constructed stormwater pond with an iron-enhanced filtration bench to allow dissolved phosphorus removal. To achieve this, the user is asked whether amendments have been incorporated into the pond design. The user answers yes or no. If the user answers "No", there is no removal of dissolved phosphorus. If the user answers "Yes", phosphorus removal is 40 percent of the influent dissolved phosphorus. This removal value is not affected by the pond design level. | ||
*The particulate phosphorus credit has been reduced from 62 to 60 percent for Design Level 1 ponds to match the TSS reduction. Particulate pollutant removal cannot exceed sediment removal. | *The particulate phosphorus credit has been reduced from 62 to 60 percent for Design Level 1 ponds to match the TSS reduction. Particulate pollutant removal cannot exceed sediment removal. | ||
Line 39: | Line 40: | ||
{{alert|If a pond does not meet the basic requirements of Level 1, it should not be included in your site calculations as the pond is unlikely to provide adequate treatment|alert-warning}} | {{alert|If a pond does not meet the basic requirements of Level 1, it should not be included in your site calculations as the pond is unlikely to provide adequate treatment|alert-warning}} | ||
− | *Design Level 1 (TSS = 60%, DP = 0%, PP =60%, TP = 34%): Must meet all of the design requirements for Design Level 1 and does not meet all design requirements for Design Level 2 | + | *Design Level 1 (TSS = 60%, DP = 0%, PP =60%, TP = 34%): Must meet all of the design requirements for Design Level 1 and does not meet all design requirements for Design Level 2 |
**Dead (or permanent) storage of at least 1800 cubic feet per acre (=1/2 inch of impervious area) that drains to the pond | **Dead (or permanent) storage of at least 1800 cubic feet per acre (=1/2 inch of impervious area) that drains to the pond | ||
**The pond’s permanent storage volume must reach a minimum depth of at least 3 feet and must have no depth greater than 10 feet. The basin must be configured such that scour or resuspension of solids is minimized. | **The pond’s permanent storage volume must reach a minimum depth of at least 3 feet and must have no depth greater than 10 feet. The basin must be configured such that scour or resuspension of solids is minimized. | ||
− | **Flow path length to pond width ratio | + | **<span title="The route that water takes when moving through a channel, bmp (e.g. a stormwater pond), or other structure."> '''Flow path'''</span> length to pond width ratio less than 1:1 or greater than 10:1 (scouring occurs at ratios greater than 10:1) |
− | *Design Level 2 (TSS = 84%, DP = | + | *Design Level 2 (TSS = 84%, DP = 0.08%, PP = 84%, TP = 50%): Meets all of the requirements for Design Levels 1 and 2 (except flow path) and does not meet all design requirements for Design Level 3 |
**Water quality volume (flood pool volume) >= 1 inch of impervious area | **Water quality volume (flood pool volume) >= 1 inch of impervious area | ||
− | **Discharge rate of water quality volume does not exceed 5.66 cubic feet per second per acre of surface area of the pond | + | **Discharge rate of water quality volume does not exceed 5.66 cubic feet per second per acre of surface area of the pond |
**Flow path length to pond width ratio = 1:1 to 3:1. A ratio of 3:1 is recommended. | **Flow path length to pond width ratio = 1:1 to 3:1. A ratio of 3:1 is recommended. | ||
− | *Design Level 3 (TSS 90%, DP = 23%, PP = 90%, TP = 60%): Must meet all of the design requirements | + | *Design Level 3 (TSS 90%, DP = 0.23%, PP = 90%, TP = 60%): Must meet all of the following design requirements |
+ | **Water quality volume (flood pool volume) > 1.5 inch of impervious area | ||
+ | **Discharge rate of water quality volume does not exceed 5.66 cubic feet per second per acre of surface area of the pond | ||
**Wet extended detention or multi-cell system | **Wet extended detention or multi-cell system | ||
**Sediment forebay at all major inflows | **Sediment forebay at all major inflows | ||
**Flow path length to pond width ratio 3:1 to 10:1 | **Flow path length to pond width ratio 3:1 to 10:1 | ||
− | |||
NOTE: The user can modify event mean concentrations (EMCs) on the Site Information tab in the calculator. Default concentrations are 54.5 milligrams per liter for total suspended solids (TSS) and 0.3 milligrams per liter for total phosphorus (particulate plus dissolved). The calculator will notify the user if the default is changed. Changing the default EMC will result in changes to the total pounds of pollutant reduced. | NOTE: The user can modify event mean concentrations (EMCs) on the Site Information tab in the calculator. Default concentrations are 54.5 milligrams per liter for total suspended solids (TSS) and 0.3 milligrams per liter for total phosphorus (particulate plus dissolved). The calculator will notify the user if the default is changed. Changing the default EMC will result in changes to the total pounds of pollutant reduced. | ||
Line 60: | Line 62: | ||
{{alert|If a pond does not meet the basic requirements of Level 1, it should not be included in your site calculations as the pond is unlikely to provide adequate treatment|alert-warning}} | {{alert|If a pond does not meet the basic requirements of Level 1, it should not be included in your site calculations as the pond is unlikely to provide adequate treatment|alert-warning}} | ||
− | *Design Level 1 (TSS = 60%, DP = 40%, PP = | + | *Design Level 1 (TSS = 60%, DP = 40%, PP =60%, TP = 52%): Must meet all of the design requirements for Design Level 1 and does not meet all design requirements for Design Level 2 |
**Dead (or permanent) storage of at least 1800 cubic feet per acre (=1/2 inch of impervious area) that drains to the pond | **Dead (or permanent) storage of at least 1800 cubic feet per acre (=1/2 inch of impervious area) that drains to the pond | ||
**The pond’s permanent storage volume must reach a minimum depth of at least 3 feet and must have no depth greater than 10 feet. The basin must be configured such that scour or resuspension of solids is minimized. | **The pond’s permanent storage volume must reach a minimum depth of at least 3 feet and must have no depth greater than 10 feet. The basin must be configured such that scour or resuspension of solids is minimized. | ||
− | **Flow path length to pond width ratio | + | **<span title="The route that water takes when moving through a channel, bmp (e.g. a stormwater pond), or other structure."> '''Flow path'''</span> length to pond width ratio less than 1:1 or greater than 10:1 (scouring occurs at ratios greater than 10:1) |
− | *Design Level 2 (TSS = 84%, DP = 40%, PP = 84%, TP = | + | *Design Level 2 (TSS = 84%, DP = 40%, PP = 84%, TP = 64%): Meets all of the requirements for Design Levels 1 and 2 (except flow path) and does not meet all design requirements for Design Level 3 |
**Water quality volume (flood pool volume) >= 1 inch of impervious area | **Water quality volume (flood pool volume) >= 1 inch of impervious area | ||
− | **Discharge rate of water quality volume does not exceed 5.66 cubic feet per second per acre of surface area of the pond | + | **Discharge rate of water quality volume does not exceed 5.66 cubic feet per second per acre of surface area of the pond |
**Flow path length to pond width ratio = 1:1 to 3:1. A ratio of 3:1 is recommended. | **Flow path length to pond width ratio = 1:1 to 3:1. A ratio of 3:1 is recommended. | ||
− | *Design Level 3 (TSS 90%, DP = 40%, PP = 90%, TP = | + | *Design Level 3 (TSS 90%, DP = 40%, PP = 90%, TP = 68%): Must meet all of the following design requirements |
+ | **Water quality volume (flood pool volume) > 1.5 inch of impervious area | ||
+ | **Discharge rate of water quality volume does not exceed 5.66 cubic feet per second per acre of surface area of the pond | ||
**Wet extended detention or multi-cell system | **Wet extended detention or multi-cell system | ||
**Sediment forebay at all major inflows | **Sediment forebay at all major inflows | ||
**Flow path length to pond width ratio 3:1 to 10:1 | **Flow path length to pond width ratio 3:1 to 10:1 | ||
− | |||
==Routing== | ==Routing== | ||
Line 82: | Line 85: | ||
*The constructed stomwater pond meets all design requirements for the selected Design Level. | *The constructed stomwater pond meets all design requirements for the selected Design Level. | ||
− | ==Example for Constructed Stormwater Pond | + | ==Example for Constructed Stormwater Pond== |
[[File:Schematic for constructed pond example.jpg|left|thumb|300 px|alt=schematic for MIDS calculator constructed pond example|<font size=3>Schematic for the MIDS calculator example for a constructed stormwater pond. See Step 1.</font size>]] | [[File:Schematic for constructed pond example.jpg|left|thumb|300 px|alt=schematic for MIDS calculator constructed pond example|<font size=3>Schematic for the MIDS calculator example for a constructed stormwater pond. See Step 1.</font size>]] | ||
[[File:Site information tab constructed pond example.png|thumb|300px|alt=screen shot of Site Information tab for constructed pond|<font size=3>Screen shot of Site Information tab for MIDS calculator example for constructed stormwater pond. See Step 2.</font size>]] | [[File:Site information tab constructed pond example.png|thumb|300px|alt=screen shot of Site Information tab for constructed pond|<font size=3>Screen shot of Site Information tab for MIDS calculator example for constructed stormwater pond. See Step 2.</font size>]] | ||
[[File:Schematic tab constructed pond example.png|thumb|300px|alt=screen shot schematic tab for constructed pond|<font size=3>Screen shot of Schematic tab for MIDS calculator example for constructed stormwater pond. See Step 3.</font size>]] | [[File:Schematic tab constructed pond example.png|thumb|300px|alt=screen shot schematic tab for constructed pond|<font size=3>Screen shot of Schematic tab for MIDS calculator example for constructed stormwater pond. See Step 3.</font size>]] | ||
+ | |||
+ | This version was created using Version 2 of the Calculator. | ||
A stormwater pond is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area. All of the runoff from the watershed will be treated by the stormwater pond. The soils in the area have a unified soils classification of SM ([[Glossary#H|HSG]] type B soil). The stormwater pond will be designed to meet the specification of Design Level 2 for pollutant removal. The following steps detail how this system would be set up in the MIDS calculator. | A stormwater pond is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area. All of the runoff from the watershed will be treated by the stormwater pond. The soils in the area have a unified soils classification of SM ([[Glossary#H|HSG]] type B soil). The stormwater pond will be designed to meet the specification of Design Level 2 for pollutant removal. The following steps detail how this system would be set up in the MIDS calculator. | ||
Line 146: | Line 151: | ||
*[[Requirements, recommendations and information for using stormwater pond as a BMP in the MIDS calculator]] | *[[Requirements, recommendations and information for using stormwater pond as a BMP in the MIDS calculator]] | ||
− | [[Category:MIDS | + | [[Category:Level 3 - Models and modeling/Specific models/MIDS Calculator]] |
− | [[Category: | + | [[Category:Level 3 - Best management practices/Structural practices/Wet pond ]] |
</noinclude> | </noinclude> |
A constructed stormwater pond is a non-volume reducing BMP. While this BMP does not provide stormwater volume reduction toward the performance goal or on an annual basis, it does provide annual pollutant load reductions. Annual pollutant reductions are applied in three levels based on pond design.
For constructed stormwater pond BMP, the user must input the following parameters to calculate the pollutant load reductions associated with the BMP.
Required treatment volume, or the volume of stormwater runoff delivered to the BMP, equals the performance goal (1.1 inches or user-specified performance goal) times the impervious area draining to the BMP. This stormwater is delivered to the BMP instantaneously.
This BMP does not provide volume reduction towards the performance goal.
Pollutant load reductions are calculated on an annual basis. A stormwater pond does not provide annual stormwater volume reduction. Annual pollutant load reductions are applied based on the selected Design Level and whether or not an amendment is incorporated into the BMP. To apply a design level in the calculator the constructed stormwater pond must meet the design requirements described in the next two sections. NOTE:DP = dissolved phosphorus, PP = particulate phosphorus, TP = total phosphorus
If the User selects "NO" to the question about the presence of an amendment, the design levels and pollutant removal is as follows.
NOTE: The user can modify event mean concentrations (EMCs) on the Site Information tab in the calculator. Default concentrations are 54.5 milligrams per liter for total suspended solids (TSS) and 0.3 milligrams per liter for total phosphorus (particulate plus dissolved). The calculator will notify the user if the default is changed. Changing the default EMC will result in changes to the total pounds of pollutant reduced.
If the User selects "YES" to the question about the presence of an amendment, the design levels and pollutant removal is as follows.
A constructed stormwater pond can be routed to any other BMP except for a green roof and a swale side slope or any BMP in a treatment sequence that would cause stormwater to be rerouted back to the stormwater pond already in the sequence. All BMPs except for a swale side slope can be routed to a constructed stormwater pond.
The following general assumptions apply in calculating the credit for a stormwater pond. If these assumptions are not followed, the pollutant reduction credits cannot be applied.
This version was created using Version 2 of the Calculator.
A stormwater pond is to be constructed in a watershed that contains a 1.4 acre parking lot surrounded by 0.8 acres of pervious area. All of the runoff from the watershed will be treated by the stormwater pond. The soils in the area have a unified soils classification of SM (HSG type B soil). The stormwater pond will be designed to meet the specification of Design Level 2 for pollutant removal. The following steps detail how this system would be set up in the MIDS calculator.
Step 1: Determine the watershed characteristics of your entire site. For this example we have a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. The pervious area does not include the pond area.
Step 2: Fill in the site specific information into the Site Information tab. This includes entering a Zip Code (55414 for this example) and the watershed information in Step 1.
Step 3: Goto the Schematic tab and drag and drop the Stormwater Pond icon into the Schematic Window
Step 4: Open the BMP properties for the stormwater pond by right clicking on the Constructed stormwater Pond icon and selecting Edit BMP properties, or by double clicking on the Constructed stormwater pond icon.
Step 5: If help is needed, click on the Minnesota Stormwater Manual Wiki link or the Help button to review input parameter specifications and calculation specific to the Constructed stormwater pond BMP.
Step 6: Determine the watershed characteristics for the stormwater pond. For this example the entire site is draining to the wetland. The watershed parameters therefore include a 2.2 acre site with 1.4 acres of impervious area and 0.8 acres of pervious turf area in type B soils. There is no routing for this BMP. Fill in the BMP specific watershed information (1.4 acres on impervious cover and 0.8 acres of Managed Turf in B soils).
Step 7: Enter the BMP design parameters for the constructed stormwater pond into the BMP parameters tab. For this BMP all that is required is to specify the Design Level that the stormwater pond meets. This pond will be constructed to meet Design Level 2. Press the help button to review design specification required for each design level. Pollutant reduction rates are associated with each design level. A constructed stormwater pond does not provide volume reduction towards the performance goal or on an annual basis.
Step 8: Click on BMP Summary tab to view results for this BMP.
Step 9: Click on the OK button to exit the BMP properties screen.
Step 10: Click on Results tab to see overall results for the site.
This page was last edited on 23 November 2022, at 19:09.