<font size=3>'''Summary of State of Minnesota water quality guidelines for stormwater harvesting and reuse systems for Irrigation'''</font size><br>
<center><font size=3>'''Summary of sate of Minnesota water quality guidelines for stormwater harvesting and reuse systems for Irrigation'''</font size><br>
+
Link to this [[Summary of sate of Minnesota water quality guidelines for stormwater harvesting and reuse systems for Irrigation|table]]
Link to this [[Summary of sate of Minnesota water quality guidelines for stormwater harvesting and reuse systems for Irrigation|table]]</center>
 
 
<table class="sortable">
 
<table class="sortable">
 
<tr>
 
<tr>
Line 19: Line 18:
 
<td>2,3</td>
 
<td>2,3</td>
 
</tr>
 
</tr>
 
 
<tr>
 
<tr>
 
<td>Turbidity</td>
 
<td>Turbidity</td>
Line 37: Line 35:
 
<td>4,5,6</td>
 
<td>4,5,6</td>
 
</tr>
 
</tr>
 
 
<tr>
 
<tr>
 
<td>pH</td>
 
<td>pH</td>
Line 46: Line 43:
 
<td>4</td>
 
<td>4</td>
 
</tr>
 
</tr>
 
 
<tr>
 
<tr>
 
<td>Chloride</td>
 
<td>Chloride</td>
Line 55: Line 51:
 
<td>7</td>
 
<td>7</td>
 
</tr>
 
</tr>
 
 
<tr>
 
<tr>
 
<td>Zinc</td>
 
<td>Zinc</td>
Line 64: Line 59:
 
<td>8</td>
 
<td>8</td>
 
</tr>
 
</tr>
 
 
<tr>
 
<tr>
 
<td>Copper</td>
 
<td>Copper</td>
Line 85: Line 79:
  
 
</table>
 
</table>
<p><sup>2</sup> – MPCA Bacterial Impairment Standard: 126 E. coli/100mL (geometric mean of 5 samples in 30 day period); no individual samples greater than 1260 E. coli/100mL</p>
+
<font size=1><sup>2</sup> – MPCA Bacterial Impairment Standard: 126 E. coli/100mL (geometric mean of 5 samples in 30 day period); no individual samples greater than 1260 E. coli/100mL<br>
<p><sup>3</sup> – EPA 2012 Recreational Water Quality Criteria – Recommendation 1 (Estimated illness rate = 36/1000)</p>
+
<sup>3</sup> – EPA 2012 Recreational Water Quality Criteria – Recommendation 1 (Estimated illness rate = 36/1000)<br>
<p><sup>4</sup> – Based on typical range/value for water reuse programs in other states</p>
+
<sup>4</sup> – Based on typical range/value for water reuse programs in other states<br>
<p><sup>5</sup> –Useful for distribution system design, but often used a general indicator parameter, too.</p>
+
<sup>5</sup> –Useful for distribution system design, but often used a general indicator parameter, too.<br>
<p><sup>6</sup> – TSS guidance provided by Cathy Tran, DLI</p>
+
<sup>6</sup> – TSS guidance provided by Cathy Tran, DLI<br>
<p><sup>7</sup> – Per Table R.3b.6 in Metropolitan Council Stormwater Reuse Guide</p>
+
<sup>7</sup> – Per Table R.3b.6 in Metropolitan Council Stormwater Reuse Guide<br>
<p><sup>8</sup> – Suggested by Bruce Wilson. Per Table R.3b.5 in Metropolitan Council Stormwater Reuse Guide</p>
+
<sup>8</sup> – Suggested by Bruce Wilson. Per Table R.3b.5 in Metropolitan Council Stormwater Reuse Guide<br>
<p><sup>9</sup> - Recommendation from Anita Anderson on 12/6/2012 email as temperature impacts bacterial growth</p>
+
<sup>9</sup> - Recommendation from Anita Anderson on 12/6/2012 email as temperature impacts bacterial growth<br>
<p><sup>10</sup> –Per Tables R.1a.1 and R.3b.5 in Metropolitan Council Stormwater Reuse Guide</p>
+
<sup>10</sup> –Per Tables R.1a.1 and R.3b.5 in Metropolitan Council Stormwater Reuse Guide</font size>
  
[[category:Table]]
+
<noinclude>[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Harvest and reuse]]</noinclude>

Latest revision as of 20:16, 3 August 2022

Summary of State of Minnesota water quality guidelines for stormwater harvesting and reuse systems for Irrigation
Link to this table

Water Quality Parameter Impact of Parameter 10 Water Quality Guideline – Public Access Areas Water Quality Guideline – Restricted Access Areas Water Quality Guideline – Irrigation of Food Crops Comments
E. coli Public Health 126 E. coli/100mL Guidance to be determined at a future date Guidance to be determined at a future date 2,3
Turbidity Irrigation System Function 2-3 NTU Guidance to be determined at a future date Guidance to be determined at a future date 4,5
TSS Irrigation System Function 5 mg/L Guidance to be determined at a future date Guidance to be determined at a future date 4,5,6
pH Plant Health 6-9 Guidance to be determined at a future date Guidance to be determined at a future date 4
Chloride Plant Health; Corrosion of Metals 500 mg/L Guidance to be determined at a future date Guidance to be determined at a future date 7
Zinc Plant Health 2 mg/L (longterm use); 10 mg/L (shortterm use) Guidance to be determined at a future date Guidance to be determined at a future date 8
Copper Plant Health 0.2 mg/L (longterm use); 5 mg/L (shortterm use) Guidance to be determined at a future date Guidance to be determined at a future date 8
Temperature Public Health Guidance to be determined at a future date Guidance to be determined at a future date Guidance to be determined at a future date 9

2 – MPCA Bacterial Impairment Standard: 126 E. coli/100mL (geometric mean of 5 samples in 30 day period); no individual samples greater than 1260 E. coli/100mL
3 – EPA 2012 Recreational Water Quality Criteria – Recommendation 1 (Estimated illness rate = 36/1000)
4 – Based on typical range/value for water reuse programs in other states
5 –Useful for distribution system design, but often used a general indicator parameter, too.
6 – TSS guidance provided by Cathy Tran, DLI
7 – Per Table R.3b.6 in Metropolitan Council Stormwater Reuse Guide
8 – Suggested by Bruce Wilson. Per Table R.3b.5 in Metropolitan Council Stormwater Reuse Guide
9 - Recommendation from Anita Anderson on 12/6/2012 email as temperature impacts bacterial growth
10 –Per Tables R.1a.1 and R.3b.5 in Metropolitan Council Stormwater Reuse Guide