m |
m |
||
Line 1: | Line 1: | ||
− | <center><font size=3>''' | + | <center><font size=3>'''This table shows comparison of phosphorus removal for different BMPs.<sup>a,e,f</sup> Values represent the percent of incoming pollutant that is removed. Source: MPCA Minnesota Stormwater Manual.</font size>'''<br> |
Link to this [[BMP pollutant removal for phosphorus|table]]</center> | Link to this [[BMP pollutant removal for phosphorus|table]]</center> | ||
{{alert|Removal rates shown here are composite averages intended solely for use in comparing performance between BMP designs and for use in calculating load reduction in site-based TP models. They have been adapted, rounded and slightly discounted from statistical values published in BMP performance databases.|alert-caution}} | {{alert|Removal rates shown here are composite averages intended solely for use in comparing performance between BMP designs and for use in calculating load reduction in site-based TP models. They have been adapted, rounded and slightly discounted from statistical values published in BMP performance databases.|alert-caution}} | ||
Line 90: | Line 90: | ||
<sup>g</sup>Note that soluble P can transfer from surface water to groundwater, but this column refers only to surface water<br> | <sup>g</sup>Note that soluble P can transfer from surface water to groundwater, but this column refers only to surface water<br> | ||
<sup>h</sup>Note that 100% is assumed for all infiltration, but only for that portion of the flow fully treated in the infiltration facility; by-passed runoff or runoff diverted via underdrain does not receive this level of treatment.</font size> | <sup>h</sup>Note that 100% is assumed for all infiltration, but only for that portion of the flow fully treated in the infiltration facility; by-passed runoff or runoff diverted via underdrain does not receive this level of treatment.</font size> | ||
+ | [[category:table]] |
BMP group | BMP design variation | Average TP removal rateb | Maximum TP removal ratec | Average soluble P removal rated,g |
---|---|---|---|---|
Bioretention | Underdrain | 65 | 75 | 60 |
Infiltration | 100 | 100 | 100 | |
Filtration | Sand filter | 50 | 55 | 0 |
Dry swale | 0 | 55 | 0 | |
Wet swale | 65 | 75 | 70 | |
Infiltrationf | Infiltration trench | 100 | 100 | 100 |
Infiltration basin | 100 | 100 | 100 | |
Stormwater ponds | Wet pond | 50 | 65 | 70 |
Multiple pond | 60 | 75 | 75 | |
Stormwater wetlands | Shallow wetland | 40 | 55 | 50 |
Pond/wetland | 55 | 75 | 65 |
a Removal rates show in table are a composite of five sources: [(http://www.bmpdatabase.org ASCE/EPA International Database]; Caraco (Center for Watershed protection, 2001); Maryland Department of the Environment(2000); Winer (Center for Watershed Protection, 2000); P8 modeling (William Walker)
b Average removal efficiency expected under MPCA Sizing Rules 1 and 3
c Upper limit on phosphorus removal with increased sizing and design features, based on national review
d Average rate of soluble phosphorus removal in the literature
e See section on calculating credits for each BMP in this Manual.
f Note that the performance numbers apply only to that portion of total flow actually being treated; it does not include any runoff that bypasses the BMP
gNote that soluble P can transfer from surface water to groundwater, but this column refers only to surface water
hNote that 100% is assumed for all infiltration, but only for that portion of the flow fully treated in the infiltration facility; by-passed runoff or runoff diverted via underdrain does not receive this level of treatment.