m |
m |
||
Line 15: | Line 15: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>BMP is < 100 feet from drinking well in sensitive aquifer</td> | + | <td>BMP is < 100 feet from drinking well in sensitive aquifer<sup>3</sup></td> |
<td>X</td> | <td>X</td> | ||
<td></td> | <td></td> | ||
Line 21: | Line 21: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>BMP is < 50 feet from drinking well in a non-sensitive aquifer</td> | + | <td>BMP is < 50 feet from drinking well in a non-sensitive aquifer<sup>3</sup></td> |
<td>X</td> | <td>X</td> | ||
<td></td> | <td></td> | ||
Line 118: | Line 118: | ||
</table> | </table> | ||
<font size=1><sup>1</sup>see discussion below for conditions under which infiltration is acceptable.<br> | <font size=1><sup>1</sup>see discussion below for conditions under which infiltration is acceptable.<br> | ||
− | <sup>2</sup>CGP = Construction Stormwater General Permit</font size> | + | <sup>2</sup>CGP = Construction Stormwater General Permit<br> |
+ | <sup>3</sup>See [https://www.revisor.mn.gov/rules/?id=4725.4450 Minnesota Rules Chapter 4725]</font size> |
Summary of situations where infiltration of stormwater runoff is prohibited or not recommended.
Link to this table
Condition | Prohibited | Not recommended | Not recommended unless conditions are met1 |
---|---|---|---|
Local rule or ordinance prohibits infiltration | X | ||
BMP is < 100 feet from drinking well in sensitive aquifer3 | X | ||
BMP is < 50 feet from drinking well in a non-sensitive aquifer3 | X | ||
BMP receives discharges from vehicle fueling and maintenance areas | if CGP applies2 | X | |
There is less than 3 of separation to bedrock or saturated soil | if CGP applies | X | |
BMP receives discharges from certain industrial facilities | if CGP applies | ||
BMP receives discharges from areas of contaminated soil | if CGP applies | X | |
Infiltration into BMP will mobilize contaminants in soil or groundwater | if CGP applies | X | |
BMP is located in D soils, unless infiltration allowed by LGU | if CGP applies | X | |
BMP is 1,000 feet up-gradient or 100 feet down-gradient of active karst, unless infiltration allowed by LGU | if CGP applies | X | |
BMP is located within a DWSMA, unless infiltration allowed by LGU | if CGP applies | ||
BMP is located in soils with infiltration rate > 8.3 in/hr | if CGP applies | X | |
BMP is located within 1 year travel time of drinking supply well | X | ||
BMP located within 10 feet of building or structure | X | ||
BMP located within 35 feet of a septic system | X | ||
BMP located less than 200 feet from toe of slope that exceeds 20% | X | ||
BMP receives discharges from a confirmed stormwater hotspot | X | ||
A mound beneath the BMP extends into the BMP | X |
1see discussion below for conditions under which infiltration is acceptable.
2CGP = Construction Stormwater General Permit
3See Minnesota Rules Chapter 4725