Chochstein (talk | contribs) m |
Chochstein (talk | contribs) m |
||
Line 1: | Line 1: | ||
− | <center><font size="3">''' | + | <center><font size="3">'''Table summarizing stormwater wetland design criteria'''</font size><br> |
Link to this [[Stormwater wetland design criteria|table]]</center> | Link to this [[Stormwater wetland design criteria|table]]</center> | ||
<table class="sortable"> | <table class="sortable"> |
Design Criteria | Shallow Wetland | Pond/Wetland | ED Shallow Wetland* |
---|---|---|---|
Wetland/Watershed Ratio (Ac/Ac) | 0.2 | 0.1 | 0.1 |
Minimum Drainage Area (Ac) | 25 | 10 | 25 |
Length to Width Ratio (minimum)(ft/ft) | 2:1 | 2:1 | 2:1 |
Extended Detention (ED) | No | Optional | Yes |
Allocation of Vwq (pool/marsh/ED) in % | 25/75/0 | 70/30/0(includes pond volume) | 25/25/50 |
Allocation of Surface Area (deepwater/low marsh/high marsh/semi-wet) in % | 20/35/40/5 | 45/25/25/5 (includes pond surface area) | 10/35/45/10 |
Forebay | Required | Required | Required |
Micropool | Required | Required | Required |
Outlet Configuration | Reverse-slope pipe or hooded broad-crested weir | Reverse-slope pipe or hooded broad-crested weir | Reverse-slope pipe or hooded broad-crested weir |
*Note: The ED Shallow Wetland design guidance does not meet the MPCA requirements for permanent volume. The guidance may be applied in a stormwater retrofit situation where area requirements preclude the use of a Shallow Wetland