Link to this table

Stormwater BMP Illustration Pollutant Removal Mechanism Location in Treatment Train Pollutant Removal 1,2 Potential Application 1
Infiltration Basin
Infiltration basin icon.png
Sedimentation / Infiltration End TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High

Pathogens: High
Residential: Yes

Commercial: Yes Ultra Urban: Limited Industrial: Limited Retrofit: Yes

Highway/Road: Limited
Bioinfiltration Basin
Bioinfiltration icon.png
Sedimentation / Infiltration Beginning TSS: High

TN: Low/Medium TP: Medium/High Chloride: Low Metals: High

Oils and Grease: High
Residential: Yes

Commercial: Yes Ultra Urban: Limited Industrial: Limited Retrofit: Yes

Highway/Road: Limited
Infiltration Trench Synonym: Infiltration Gallery
Infiltration trench icon.png
Infiltration nd TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High

Pathogens: High
Residential: Yes

Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes

Highway/Road: Yes
Dry Well Synonym: Infiltration Tube, French Drain, Soak‐Away Pits, Soak Holes
Dry well icon.png
Infiltration throughout TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High

Pathogens: High
Residential: Yes

Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes

Highway/Road: No
Underground Infiltration
Underground infiltration icon.png
Sedimentation / Infiltration / Flotation/Skimming End TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High

Pathogens: High
Residential: Yes

Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes

Highway/Road: Limited
Dry Swale with Check Dams
Swale check icon.png
Sedimentation / Infiltration Throughout TSS: High

TN: Low/Medium TP: Low/Medium Chloride: Low Metals: High Oils and Grease: High

Pathogens: Medium
Residential: Yes

Commercial: Yes Ultra Urban: Limited Industrial: Yes Retrofit: Limited

Highway/Road: Yes
Permeable Pavement
Permeable pavement icon.png
Infiltration Beginning TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High

Oils and Grease: High
Residential: Yes

Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes

Highway/Road: Limited
Tree Trench/Tree Box
Tree trench icon.png
Infiltration, Transpiration Throughout TSS: High

TN: Medium/High TP: Medium/High Chloride: Low Metals: High Oils and Grease: High

Pathogens: High
Residential: Limited

Commercial: Yes Ultra Urban: Yes Industrial: Limited Retrofit: Yes

Highway/Road: Limited

1 Treatment Capabilities and Potential Applications referenced from Manual Section BMP's for stormwater infiltration
2 Low = < 30%; Medium = 30‐65%; High = 65‐100%