m ()
m ()
Line 125: Line 125:
 
</tr>
 
</tr>
 
<tr>
 
<tr>
<td colspan=9><font size=1><sup>1</sup> Only data meeting TAPE inflow requirements was available.</font size></td>
+
<td colspan=11><font size=1><sup>1</sup> Only data meeting TAPE inflow requirements was available.</font size></td>
 
</tr>
 
</tr>
 
</table>
 
</table>

Revision as of 15:22, 21 July 2021

Data summary for manufactured treatment devices
Link to this table

Manufactured treatment device Median inflow TP (mg/L) TP Removal (%) TSS removal (%)
Median Mean LCL TAPE median TAPE LCL Median Mean TAPE median LCL
Filterra 0.09 67.0 60.1 52.2 78.5 69.2 89.5 86.2 89.3 82.8
Phosphosorb 0.28 81.5 77.4 70.0 78.7 63.6 91.6 88.1 84.8 91.6
Up-Flo 0.11 43.1 32.1 19.1 57.1 49.9 75 67.6 77.5 59.9
Modular wetland 0.1 62.1 60.2 52.7 63.3 54.0 81.9 76.6 82.9 71.2
BayFilter1 0.16 68.6 64.0 59.4 68.6 58.2 89.3 86.1 89.3 79.2 - 81.1
StormGarden 0.078 58.7 56.3 51.6 58.9 43.2 89.2 86.0 91.9 82.8
BioPod 0.104 71.7 66.7 59.5 75.4 62.4 83.3 86.5 91.9 82.1
FloGard 0.123 63.6 60.1 50.7; 55.4 without outlier 70.7 48.8 (60.6 without outlier) 80.6 74.7 81.1 68.5
1 Only data meeting TAPE inflow requirements was available.