Temporary sediment control: corrective actions
Link to this table
Item |
Corrective Action Required if |
Corrective Action1 |
Storm drain inlet protection |
- Inlet opening unprotected
- Emergency overflow not provided where required
- Device not cleaned out
- Improper inlet protection for scope of work
- Flooding occurring in public use drive lanes
|
- Immediately install inlet control device appropriate to the work
- Immediately correct missing overflow condition
- Immediately restore function of inlet control device
- Immediately correct inlet device for scope of work
- Immediately correct flooding condition by changing device or flow constriction
|
1The number corresponds with the same number in the column "Corrective Action Required"