m
m
Line 1: Line 1:
<font size=3>'''Minimum setback requirements.  This represents the minimum distance from the infiltration practice to the structure of concern.  If the structure is aboveground, the distance is measured from the edge of the permeable pavement to the structure.  If the structure is underground, the setback distance represents the distance from the point of infiltration through the bottom of the permeable pavement system to the structure.'''</font size><br>
+
<font size=3>'''Recommended minimum setback requirements.  This represents the minimum distance from the infiltration practice to the structure of concern.  If the structure is aboveground, the distance is measured from the edge of the permeable pavement to the structure.  If the structure is underground, the setback distance represents the distance from the point of infiltration through the bottom of the permeable pavement system to the structure.'''</font size><br>
 
Link to this [[Minimum setback requirements|table]]
 
Link to this [[Minimum setback requirements|table]]
 
<table class="sortable"><tr>
 
<table class="sortable"><tr>

Revision as of 13:05, 7 April 2014

Recommended minimum setback requirements. This represents the minimum distance from the infiltration practice to the structure of concern. If the structure is aboveground, the distance is measured from the edge of the permeable pavement to the structure. If the structure is underground, the setback distance represents the distance from the point of infiltration through the bottom of the permeable pavement system to the structure.
Link to this table

Setback from Minimum Distance [feet]
Property Line 10
Building Foundation* 10
Private Well 50
Public Water Supply Well 50
Septic System Tank/Leach Field 35