[[File:Swale with underdrain BMP parameters tab.png|300px|thumb|alt=Schematic of Swale with underdrain BMP parameters tab|<font size=3>Schematic of BMP parameters tab for Swale Main Channel (with underdrain). The user must enter values for all blank cells.</font size>]] | [[File:Swale with underdrain BMP parameters tab.png|300px|thumb|alt=Schematic of Swale with underdrain BMP parameters tab|<font size=3>Schematic of BMP parameters tab for Swale Main Channel (with underdrain). The user must enter values for all blank cells.</font size>]] | ||
− | A swale main channel with an underdrain behaves similarly to a [[Bioretention|bioretention]] BMP with an [[Glossary#U|underdrain]]. Volume retention is achieved through [[Glossary#I|infiltration]] of water stored in the pore spaces of engineered media between the invert of an elevated underdrain and the native soils. If the underdrain is not elevated above the native soils then volume reduction is achieved through infiltration below the underdrain. Volume retention also occurs by [[Glossary#E|evapotranspiration]] through the vegetation in the swale. If runoff to the main channel flows over a side slope through sheet flow, a swale side slope BMP should be used in combination with the swale main channel BMP. All pollutants in the infiltrated water are credited as being reduced. A portion of pollutants in the stormwater that flows through an underdrain are removed through [[Glossary#F|filtration]]. | + | A swale main channel with an underdrain behaves similarly to a [[Bioretention|bioretention]] BMP with an [[Glossary#U|underdrain]]. Volume retention is achieved through [[Glossary#I|infiltration]] of water stored in the pore spaces of engineered media between the invert of an elevated underdrain and the native soils. If the underdrain is not elevated above the native soils then volume reduction is achieved through infiltration below the underdrain. Volume retention also occurs by [[Glossary#E|evapotranspiration]] through the vegetation in the swale. If runoff to the main channel flows over a side slope through sheet flow, then a swale side slope BMP should be used in combination with the swale main channel BMP in the MIDS calculator. All pollutants in the infiltrated water are credited as being reduced. A portion of pollutants in the stormwater that flows through an underdrain are removed through [[Glossary#F|filtration]]. |
==MIDS calculator user inputs for swale main channel (with underdrain)== | ==MIDS calculator user inputs for swale main channel (with underdrain)== | ||
Line 14: | Line 14: | ||
*'''Watershed tab''' | *'''Watershed tab''' | ||
**'''BMP Name:''' this cell is auto-filled but can be changed by the user. | **'''BMP Name:''' this cell is auto-filled but can be changed by the user. | ||
− | **'''Routing/downstream BMP:''' if this BMP is part of a [[Using the treatment train approach to BMP selection|treatment train]] and water is being routed from this BMP to another BMP, the user selects the name of the BMP | + | **'''Routing/downstream BMP:''' if this BMP is part of a [[Using the treatment train approach to BMP selection|treatment train]] and water is being routed from this BMP to another BMP, the user selects the name of the BMP to which water is being routed from the dropdown box. All water must be routed to a single downstream BMP. Note that the BMP receiving the routed water must be included by the user in the Schematic tab or the BMP will not appear in the dropdown box. |
**'''BMP Watershed Area:''' BMP watershed areas are the areas draining directly to the BMP. Values can be added for four soil types ([[Glossary#H|Hydrologic Soil Groups]] (HSG) A, B, C, D) and for three Land Cover types (Forest/Open Space, Managed Turf and Impervious). The surface area of the BMP should be included as managed turf land cover of the hydrologic soil type of the native soils that are located under the BMP. Units are in acres. | **'''BMP Watershed Area:''' BMP watershed areas are the areas draining directly to the BMP. Values can be added for four soil types ([[Glossary#H|Hydrologic Soil Groups]] (HSG) A, B, C, D) and for three Land Cover types (Forest/Open Space, Managed Turf and Impervious). The surface area of the BMP should be included as managed turf land cover of the hydrologic soil type of the native soils that are located under the BMP. Units are in acres. | ||
− | **If a swale side slope is routed to this BMP, do not include the side slope watershed areas in the Watershed tab for the swale main channel since this would effectively double-count the side slope contributing area. | + | ***If a swale side slope is routed to this BMP, do not include the side slope watershed areas in the Watershed tab for the swale main channel since this would effectively double-count the side slope contributing area. |
*'''BMP Parameters tab''' | *'''BMP Parameters tab''' | ||
Line 28: | Line 28: | ||
**'''Media porosity minus field capacity (n - FC)''' - This is the amount of water between [[Glossary#P|media porosity]] and [[Glossary#F|field capacity]] stored between the underdrain invert and the bottom of the media (top of native soil). If multiple types of media are used in the BMP, this value should be a weighted average of [[Soil water storage properties|the soil water storage values of the media ]] installed between the underdrain and the native soils. The user inputs this value in cubic feet of pore space per cubic feet of media. The recommended range for this value is 0.15 to 0.35. | **'''Media porosity minus field capacity (n - FC)''' - This is the amount of water between [[Glossary#P|media porosity]] and [[Glossary#F|field capacity]] stored between the underdrain invert and the bottom of the media (top of native soil). If multiple types of media are used in the BMP, this value should be a weighted average of [[Soil water storage properties|the soil water storage values of the media ]] installed between the underdrain and the native soils. The user inputs this value in cubic feet of pore space per cubic feet of media. The recommended range for this value is 0.15 to 0.35. | ||
**'''Planting media mix:''' The user selects the type of [[Design criteria for bioretention#Materials specifications - filter media|media mix]] installed for planting from a predefined list of Media mixes: Media mix A (water quality blend), Media mix B (enhanced filtration blend), Media mix C (North Carolina State University water quality blend), Media mix D, or Other. This value is used to determine the annual phosphorus load reduction credit. | **'''Planting media mix:''' The user selects the type of [[Design criteria for bioretention#Materials specifications - filter media|media mix]] installed for planting from a predefined list of Media mixes: Media mix A (water quality blend), Media mix B (enhanced filtration blend), Media mix C (North Carolina State University water quality blend), Media mix D, or Other. This value is used to determine the annual phosphorus load reduction credit. | ||
− | **'''Is the P content of the media less than 30 mg/kg?:''' This is a YES/NO question. The P content of the planting media should be tested using the [[Design criteria for bioretention#Notes about soil phosphorus testing: applicability and interpretation|Mehlich 3 test]] or an acceptable alternative method. Select YES if the P content of the planting media is less than 30 milligrams per kilogram and NO if it is greater. P content testing is not needed for planting media C or D; therefore, this item will automatically populate to YES if one of those two media types are selected. This value is used to determine the annual phosphorus load reduction credit. | + | **'''Is the P content of the media less than 30 mg/kg?:''' This is a YES/NO question. The P content of the planting media should be tested using the [[Design criteria for bioretention#Notes about soil phosphorus testing: applicability and interpretation|Mehlich 3 test]] or an [[Design criteria for bioretention#Notes about soil phosphorus testing: applicability and interpretation|acceptable alternative method]]. Select YES if the P content of the planting media is less than 30 milligrams per kilogram and NO if it is greater. P content testing is not needed for planting media C or D; therefore, this item will automatically populate to YES if one of those two media types are selected. This value is used to determine the annual phosphorus load reduction credit. |
**'''Is a soil amendment used to attenuate phosphorus?:''' This is a YES/NO question. Answer YES if the bioretention filter media contains soil amendments to enhance phosphorus sorption and NO if amendments are not used. This value is used to determine the annual phosphorus load reduction credit. | **'''Is a soil amendment used to attenuate phosphorus?:''' This is a YES/NO question. Answer YES if the bioretention filter media contains soil amendments to enhance phosphorus sorption and NO if amendments are not used. This value is used to determine the annual phosphorus load reduction credit. | ||
**'''Underlying soil - Hydrologic Soil Group:''' The user selects the most restrictive soil (lowest hydraulic conductivity) occurring within the 3 feet below the media/native soil interface of the swale main channel. There are 14 soil options that fall into 4 different Hydrologic Soil Groups (Hydrologic Soil Group (HSG) A, B, C, or D) for the user. Once a soil type is selected, the corresponding [[Design infiltration rates|infiltration rate]] will populate the “Infiltration rate of underlying soils” field. The user may also select “User Defined.” This selection will activate the “User Defined Infiltration Rate” cell, allowing the user to enter a different value from the values in the predefined selection list. The maximum allowable infiltration rate is 1.63 inches per hour. | **'''Underlying soil - Hydrologic Soil Group:''' The user selects the most restrictive soil (lowest hydraulic conductivity) occurring within the 3 feet below the media/native soil interface of the swale main channel. There are 14 soil options that fall into 4 different Hydrologic Soil Groups (Hydrologic Soil Group (HSG) A, B, C, or D) for the user. Once a soil type is selected, the corresponding [[Design infiltration rates|infiltration rate]] will populate the “Infiltration rate of underlying soils” field. The user may also select “User Defined.” This selection will activate the “User Defined Infiltration Rate” cell, allowing the user to enter a different value from the values in the predefined selection list. The maximum allowable infiltration rate is 1.63 inches per hour. | ||
− | **'''Required drawdown time:''' This is the time in which the stormwater captured by | + | **'''Required drawdown time:''' This is the time in which the stormwater captured below the underdrain by this BMP must drain into the underlying soil. The user may select from predefined values of 48 or 24 hours. The [http://www.pca.state.mn.us/index.php/water/water-types-and-programs/stormwater/construction-stormwater/index.html MPCA Construction Stormwater General Permit] ''requires'' drawdown within 48 hours, but 24 hours is <i>Highly Recommended</i> when discharges are to a trout stream. The calculator uses the underlying soil infiltration rate and the “Depth below underdrain” to check if the BMP meets the drawdown time requirement. The user will encounter an error and be required to enter a new “Depth below underdrain” if the water stored in the BMP cannot drawdown in the required time. |
*'''BMP Summary Tab:''' The BMP Summary tab summarizes the volume and pollutant reductions provided by the specific BMP. It details the performance goal volume reductions and annual average volume, dissolved P, particulate P, and TSS load reductions. Included in the summary are the total volume and pollutant loads received by the BMP from its direct watershed, from upstream BMPs, and a combined value of the two. Also included in the summary are the volume and pollutant load reductions provided by the BMP, along with the volume and pollutant loads that exit the BMP through the outflow. This outflow load and volume is what is routed to the downstream BMP, if one is defined in the Watershed tab. Finally, percent reductions are provided for the percent of the performance goal achieved, percent annual runoff volume retained, total percent annual particulate phosphorus reduction, total percent annual dissolved phosphorus reduction, total percent annual TP reduction, and total percent annual TSS reduction. | *'''BMP Summary Tab:''' The BMP Summary tab summarizes the volume and pollutant reductions provided by the specific BMP. It details the performance goal volume reductions and annual average volume, dissolved P, particulate P, and TSS load reductions. Included in the summary are the total volume and pollutant loads received by the BMP from its direct watershed, from upstream BMPs, and a combined value of the two. Also included in the summary are the volume and pollutant load reductions provided by the BMP, along with the volume and pollutant loads that exit the BMP through the outflow. This outflow load and volume is what is routed to the downstream BMP, if one is defined in the Watershed tab. Finally, percent reductions are provided for the percent of the performance goal achieved, percent annual runoff volume retained, total percent annual particulate phosphorus reduction, total percent annual dissolved phosphorus reduction, total percent annual TP reduction, and total percent annual TSS reduction. | ||
A swale main channel with an underdrain behaves similarly to a bioretention BMP with an underdrain. Volume retention is achieved through infiltration of water stored in the pore spaces of engineered media between the invert of an elevated underdrain and the native soils. If the underdrain is not elevated above the native soils then volume reduction is achieved through infiltration below the underdrain. Volume retention also occurs by evapotranspiration through the vegetation in the swale. If runoff to the main channel flows over a side slope through sheet flow, then a swale side slope BMP should be used in combination with the swale main channel BMP in the MIDS calculator. All pollutants in the infiltrated water are credited as being reduced. A portion of pollutants in the stormwater that flows through an underdrain are removed through filtration.
For a swale main channel with underdrain system, the user must input the following parameters to calculate the volume and pollutant load reductions associated with the BMP.
If the following requirements for inputs into the MIDS calculator are not met, then an error message will inform the user to change the input to meet the requirement.
\(DDT_{calc} = D_U / (I_R / 12)\)
Where
If the DDTcalc is greater than the user-defined required drawdown time then the user will be prompted to enter a new depth below the underdrain or infiltration rate of the native soils.
Required treatment volume, or the volume of stormwater runoff delivered to the BMP, is calculated as the performance goal (1.1 inches or user-specified performance goal) times the impervious area draining to the BMP. This stormwater is delivered to the BMP instantaneously following the Kerplunk method.
The volume reduction achieved by a BMP compares the capacity of the BMP to the required treatment volume. The Volume reduction capacity of BMP [V] is calculated using BMP inputs provided by the user. For this BMP, the location of the underdrain determines how the volume reduction capacity is calculated.
Underdrain located at BMP bottom: If the underdrain is located at the bottom of the BMP, then the Volume reduction capacity of BMP [V] is determined based on infiltration into the bottom of the BMP (Vinf_b) and evapotranspiration in the planting media above the underdrain (VET).
Even with an underdrain present, under saturated media conditions some water will infiltrate through the bottom soils as water in the basin draws down. The Volume reduction from basin bottom infiltration (Vinf_b) of the BMP equals the following
\(V_{Inf_B} = I_R * DDT * W_B * L_C/(12in/ft)\)
Where
The default infiltration rate is set at 0.06 inches per hour to represent a D soil. This rate was selected because it is assumed that most of the stormwater will pass through the underdrain before it can infiltrate through the bottom of the BMP. This may be a conservative assumption if underdrains are small, spaced far apart, and the underlying soil has an infiltration rate greater than 0.06 inches per hour. Conversely, more closely spaced or larger underdrains may allow the basin to drain in less than the required drawdown time, resulting in a slight overestimation of infiltration loss through the basin bottom. If the user specifies that an impermeable liner is present at the bottom of the BMP, then no credit is given for infiltration into the bottom soils.
In addition to the credit given for the infiltration below the underdrain, a swale main channel BMP can also achieve stormwater volume reduction through evapotranspiration (VET). The Volume reduction of BMP from ET (VET) is the smaller of two calculated values, potential ET (ETpot) and measured ET (ETmea).
\(ET_{pot} = (D_M - D_U ) * L_C * W_B * (FC - WP)\)
Where
\(ET_{mea} = L_C * W_B * 0.2 in/day * 0.5 *3 days / (12 in/ft) \)
ETmea and ETpot are compared and the estimated Volume reduction of BMP from ET (VET) is the smaller of the two values.
Elevated Underdrain: If the underdrain is elevated above the bottom of the BMP, then the volume reduction credit is determined based on the storage capacity in the media between the underdrain and the native soils, and evapotranspiration in the media above the underdrain (VET).
The Volume reduction stored below the underdrain is given by
\(V = L_C * W_B * (n-FC) * D_U\)
Where
The stored water must drain within the specified drawdown time. The underlying soil controls the infiltration rate. The user must input the soil with the most restrictive hydraulic conductivity in the 3 feet directly below the basin (i.e. below the bottom of the engineered media).
The VET credit is calculated with the same methods as when the underdrain is located at the bottom of the BMP (see discussion above).
The Volume of retention provided by BMP is the amount of volume credit the BMP provides toward the performance goal. This value is equal to the Volume reduction capacity of BMP [V], calculated using the above method, as long as the volume reduction capacity is less than or equal to the Required treatment volume. If Volume reduction capacity of BMP [V] is greater than Required treatment volume, then the BMP volume credit is equal to Required treatment volume. This check makes sure the BMP is not getting more credit than the amount of water it receives. For example, if the BMP is oversized the user will only receive credit for Required treatment volume routed to the BMP.
Pollutant load reductions are calculated on an annual basis. Therefore, the first step in calculating annual pollutant load reductions is converting the Volume reduction capacity of BMP, which is an instantaneous volume reduction, to an annual volume reduction percentage. This is accomplished through the use of performance curves developed from multiple modeling scenarios. The performance curves use the Volume reduction capacity of BMP [V], the infiltration rate of the underlying soils, the contributing watershed percent impervious area, and the size of the contributing watershed to calculate a percent annual volume reduction. While oversizing a BMP above the Required treatment volume will not provide additional credit towards the performance goal volume, it may provide additional pollutant reduction.
All pollutants in the infiltrated water are considered captured for a 100 percent removal. Stormwater that is captured by the swale system but that is not infiltrated or lost through ET is assumed to flow through the filter media and out the underdrain. A constant 68 percent TSS removal rate is applied to the filtered stormwater. The removal rates for particulate phosphorus and dissolved phosphorus in the filtered stormwater depend on the answers given to the three user inputs: “Planting media mix”, “Is the P content of the media less than 30 mg/kg?” and “Is a soil amendment used to attenuate phosphorus?”
Particulate Phosphorus: The particulate phosphorus credit given is either 0 percent or 45 percent depending on the media mix used and its P content.
Dissolved Phosphorus: The dissolved phosphorus credit given is between 0 percent and 60 percent depending on the media mix, the media P content, and if the media was amended to attenuate phosphorus.
\(credit = 20 * ((D_M - D_U)) / (2 ft)\)
where (DM - DU) represents the media depth above the underdrain. The credit is calculated as a percent reduction with a maximum value of 20 percent for media depths above the underdrain greater than 2 feet. If the media depth above the underdrain is less than 2 feet the credit is reduced equivalently.
Annual removal rates of particulate phosphorus and dissolved phosphorus in filtered stormwater are summarized in the following table.
NOTE: The user can modify event mean concentrations (EMCs) on the Site Information tab in the calculator. Default concentrations are 54.5 milligrams per liter for total suspended solids (TSS) and 0.3 milligrams per liter for total phosphorus (particulate plus dissolved). The calculator will notify the user if the default is changed. Changing the default EMC will result in changes to the total pounds of pollutant reduced.
Overflow from a swale main channel with an underdrain can be routed to any other BMP except for a green roof, a swale side slope, or any BMP in a stormwater treatment sequence that would cause stormwater to be rerouted back to the swale main channel already in that sequence. All BMPs can be routed to the swale main channel with an underdrain.
The following general assumption applies in calculating the credit for a swale main channel with an underdrain. If this assumption is not followed the volume and pollutant reduction credits cannot be applied.