m |
|||
Line 11: | Line 11: | ||
*Depth below underdrain (D<sub>U</sub>): The depth of the media between the underdrain invert and the native soils. Units are typically in feet. | *Depth below underdrain (D<sub>U</sub>): The depth of the media between the underdrain invert and the native soils. Units are typically in feet. | ||
*Interception capacity (IC): Depth of water (precipitation) that is intercepted by a tree. Average values used in the MIDS calculator are 0.043 inches for deciduous trees and 0.087 inches for conifers. Units are typically in inches. | *Interception capacity (IC): Depth of water (precipitation) that is intercepted by a tree. Average values used in the MIDS calculator are 0.043 inches for deciduous trees and 0.087 inches for conifers. Units are typically in inches. | ||
− | *Infiltration rate of native soils (I<sub>R</sub>): The rate at which water infiltrates into soils beneath a BMP. Usually assumed to be equal to the saturated hydraulic conductivity for a soil. Typically expressed in inches per hour. | + | *Infiltration rate of native soils (I<sub>R</sub>): The rate at which water infiltrates into soils beneath a BMP. Usually assumed to be equal to the saturated hydraulic conductivity for a soil. Typically expressed in inches per hour. Link [[Design infiltration rates|here]] for recommended design infiltration rates for different soils. |
− | *Leaf area index (LAI): a dimensionless quantity that characterizes plant canopies, defined as the one-sided green leaf area per unit ground surface area (LAI = leaf area / ground area, m2 / m2) in broadleaf canopies. Varies with tree type and tree size. | + | *Leaf area index (LAI): a dimensionless quantity that characterizes plant canopies, defined as the one-sided green leaf area per unit ground surface area (LAI = leaf area / ground area, m2 / m2) in broadleaf canopies. Varies with [http://stormwater.pca.state.mn.us/index.php/Calculating_credits_for_tree_trenches_and_tree_boxes#Evapotranspiration tree type and tree size]. |
*Measured ET (ET<sub>mea</sub>): The amount of water lost to ET as measured using available data. Units are typically cubic feet. | *Measured ET (ET<sub>mea</sub>): The amount of water lost to ET as measured using available data. Units are typically cubic feet. | ||
− | *Media field capacity minus wilting point (FC-WP): This is the amount of water between field capacity and the permanent wilting point stored in the media above the underdrain. This is water often considered to be available for uptake by plants. If multiple types of media are used in the BMP, this value should be a weighted average of the soil water storage values of the media installed above the underdrain. Values for field capacity and wilting point based on soil type can be found here. Units are typically in cubic feet of water per cubic feet of media. The recommended range for this value is 0.05 to 0.17. | + | *Media field capacity minus wilting point (FC-WP): This is the amount of water between field capacity and the permanent wilting point stored in the media above the underdrain. This is water often considered to be available for uptake by plants. If multiple types of media are used in the BMP, this value should be a weighted average of the soil water storage values of the media installed above the underdrain. Values for field capacity and wilting point based on soil type can be found here. Units are typically in cubic feet of water per cubic feet of media. The recommended range for this value is 0.05 to 0.17. For information on soil storage properties, link [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties here]. |
− | *Media porosity minus field capacity (n - FC): This is the amount of water between media porosity and field capacity stored in the media between the underdrain invert and the bottom of the media (top of native soil). If multiple types of media are used in the BMP, this value should be a weighted average of the soil water storage values of the media installed between the underdrain and the native soils. Values for porosity and field capacity based on soil type can be found here. Units are typically in cubic feet of pore space per cubic feet of media. The recommended range for this value is 0.15 to 0.35. | + | *Media porosity minus field capacity (n - FC): This is the amount of water between media porosity and field capacity stored in the media between the underdrain invert and the bottom of the media (top of native soil). If multiple types of media are used in the BMP, this value should be a weighted average of the soil water storage values of the media installed between the underdrain and the native soils. Values for porosity and field capacity based on soil type can be found here. Units are typically in cubic feet of pore space per cubic feet of media. The recommended range for this value is 0.15 to 0.35. For information on soil storage properties, link [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties here]. |
*Media surface area (A<sub>M</sub>): This is the surface area at the bottom of the ponded water within a BMP. This is therefore the area at the surface of the engineered media. Units are typically in square feet. | *Media surface area (A<sub>M</sub>): This is the surface area at the bottom of the ponded water within a BMP. This is therefore the area at the surface of the engineered media. Units are typically in square feet. | ||
*Overflow depth (D<sub>O</sub>): This is the maximum depth of ponded water within a BMP (i.e., vertical distance from the overflow elevation to the top of the soil or media). Units are typically in feet. | *Overflow depth (D<sub>O</sub>): This is the maximum depth of ponded water within a BMP (i.e., vertical distance from the overflow elevation to the top of the soil or media). Units are typically in feet. | ||
− | *Potential ET (ET<sub>pot</sub>): The amount of water stored between field capacity and the wilting point in the media above the underdrain. This water is assumed to be taken up by plants and evapotranspired. Units are typically cubic feet. | + | *Potential ET (ET<sub>pot</sub>): The amount of water stored between field capacity and the wilting point in the media above the underdrain. This water is assumed to be taken up by plants and evapotranspired. Units are typically cubic feet. For information on soil storage properties, link [http://stormwater.pca.state.mn.us/index.php/Soil_water_storage_properties here]. |
*Side slope (H:V): The ratio between the horizontal (H) and vertical (V) components of a side slope (H:V). | *Side slope (H:V): The ratio between the horizontal (H) and vertical (V) components of a side slope (H:V). | ||
*Soil volume per tree (S<sub>V</sub>): The soil volume available for each individual tree in a tree trench system. Units are typically cubic feet | *Soil volume per tree (S<sub>V</sub>): The soil volume available for each individual tree in a tree trench system. Units are typically cubic feet | ||
− | *Storage volume behind a check dam (V<sub>CD</sub>): The volume of ponded water in a swale main channel stored behind a check dam that will infiltrate into the soils. | + | *Storage volume behind a check dam (V<sub>CD</sub>): The volume of ponded water in a swale main channel stored behind a check dam that will infiltrate into the underlying soils. |
*Surface area at overflow (A<sub>O</sub>): This is the surface area of the BMP at the lowest outlet point of the surface overflow from the ponding area of the BMP. Units are typically in square feet. | *Surface area at overflow (A<sub>O</sub>): This is the surface area of the BMP at the lowest outlet point of the surface overflow from the ponding area of the BMP. Units are typically in square feet. | ||
*Surface area at underdrain (A<sub>U</sub>): This is the surface area of the BMP at the invert elevation of the underdrain. Units are in typically square feet. | *Surface area at underdrain (A<sub>U</sub>): This is the surface area of the BMP at the invert elevation of the underdrain. Units are in typically square feet. |