m
m
Line 1: Line 1:
 
Swales retain solids and associated pollutants by settling and filtering. A typical method for assessing the performance of of BMPs with underdrains is therefore measuring and comparing pollutant concentrations at the influent and effluent. If the swale is designed for infiltration, see [[Assessing the performance of bioretention]].
 
Swales retain solids and associated pollutants by settling and filtering. A typical method for assessing the performance of of BMPs with underdrains is therefore measuring and comparing pollutant concentrations at the influent and effluent. If the swale is designed for infiltration, see [[Assessing the performance of bioretention]].
  
An [http://stormwaterbook.safl.umn.edu/content/monitoring-data-analysis online manual] for assessing BMP treatment performance was developed in 2010 by Andrew Erickson, Peter Weiss, and John Gulliver from the University of Minnesota and St. Anthony Falls Hydraulic Laboratory. The manual advises on a four-level process to assess the performance of a Best Management Practice.
+
An [http://stormwaterbook.safl.umn.edu/ online manual] for assessing BMP treatment performance was developed in 2010 by Andrew Erickson, Peter Weiss, and John Gulliver from the University of Minnesota and St. Anthony Falls Hydraulic Laboratory. The manual advises on a four-level process to assess the performance of a Best Management Practice.
*Level 1: [http://stormwaterbook.safl.umn.edu/content/visual-inspection-filtration Visual Inspection]. The website includes links to a downloadable checklist.
+
*Level 1: Visual Inspection. This includes assessments for [http://stormwaterbook.safl.umn.edu/infiltration-practices/visual-inspection-infiltration-practices infiltration practices] and for [http://stormwaterbook.safl.umn.edu/filtration-practices/visual-inspection-filtration-practices filtration practices]. The website includes links to a downloadable checklist.
*Level 2: [http://stormwaterbook.safl.umn.edu/content/capacity-testing-filtration Capacity Testing]
+
*Level 2: Capacity Testing. Level 2 testing can be applied to both [http://stormwaterbook.safl.umn.edu/infiltration-practices/capacity-testing-infiltration-practices infiltration] and [http://stormwaterbook.safl.umn.edu/filtration-practices/capacity-testing-filtration-practices filtration] practices.
*Level 3: [http://stormwaterbook.safl.umn.edu/content/synthetic-runoff-testing-filtration Synthetic Runoff Testing]. Synthetic runoff test results can be used to develop an accurate characterization of pollutant retention or removal, but can be limited by the need for an available water volume and discharge.
+
*Level 3: Synthetic Runoff Testing for [http://stormwaterbook.safl.umn.edu/infiltration-practices/synthetic-runoff-testing-infiltration-practices infiltration] and [http://stormwaterbook.safl.umn.edu/filtration-practices/synthetic-runoff-testing-filtration-practices filtration] practices. Synthetic runoff test results can be used to develop an accurate characterization of pollutant retention or removal, but can be limited by the need for an available water volume and discharge.
*Level 4: [http://stormwaterbook.safl.umn.edu/content/monitoring-filtration Monitoring]
+
*Level 4: Monitoring for [http://stormwaterbook.safl.umn.edu/infiltration-practices/monitoring-infiltration-practices infiltration] or [http://stormwaterbook.safl.umn.edu/filtration-practices/monitoring-filtration-practices filtration] practices
  
 
Level 1 activities do not produce numerical performance data that could be used to obtain a stormwater management credit.  BMP owners and operators who are interested in using data obtained from Levels 2 and 3 should consult with the MPCA or other regulatory agency to determine if the results are appropriate for credit calculations.  Level 4, Monitoring, is the method most frequently used for assessment of the performance of a BMP.
 
Level 1 activities do not produce numerical performance data that could be used to obtain a stormwater management credit.  BMP owners and operators who are interested in using data obtained from Levels 2 and 3 should consult with the MPCA or other regulatory agency to determine if the results are appropriate for credit calculations.  Level 4, Monitoring, is the method most frequently used for assessment of the performance of a BMP.
  
 
Use these links to obtain detailed information on the following topics related to BMP performance monitoring:
 
Use these links to obtain detailed information on the following topics related to BMP performance monitoring:
*[http://stormwaterbook.safl.umn.edu/content/developing-assessment-program Developing an Assessment Program]
+
*[http://stormwaterbook.safl.umn.edu/developing-assessment-program Developing an Assessment Program]
*[http://stormwaterbook.safl.umn.edu/content/water-budget-measurement Water Budget Measurement]
+
*[http://stormwaterbook.safl.umn.edu/developing-assessment-program/water-budget-measurement Water Budget Measurement]
*[http://stormwaterbook.safl.umn.edu/content/sampling-methods Sampling Methods]
+
*[http://stormwaterbook.safl.umn.edu/developing-assessment-program/sampling-methods Sampling Methods]
*[http://stormwaterbook.safl.umn.edu/content/analysis-water-and-soils Analysis of Water and Soils]
+
*[http://stormwaterbook.safl.umn.edu/developing-assessment-program/analysis-water-and-soils Analysis of Water and Soils]
*[http://stormwaterbook.safl.umn.edu/content/monitoring-data-analysis Data Analysis for Monitoring]
+
*[http://stormwaterbook.safl.umn.edu/developing-assessment-program/analysis-water-and-soils Data Analysis for Monitoring]
  
 
Additional information on designing a monitoring network and performing field monitoring are found at [http://stormwater.pca.state.mn.us/index.php/Calculating_credits_for_swales#Credits_based_on_field_monitoring this link].
 
Additional information on designing a monitoring network and performing field monitoring are found at [http://stormwater.pca.state.mn.us/index.php/Calculating_credits_for_swales#Credits_based_on_field_monitoring this link].

Revision as of 20:35, 5 April 2016

Swales retain solids and associated pollutants by settling and filtering. A typical method for assessing the performance of of BMPs with underdrains is therefore measuring and comparing pollutant concentrations at the influent and effluent. If the swale is designed for infiltration, see Assessing the performance of bioretention.

An online manual for assessing BMP treatment performance was developed in 2010 by Andrew Erickson, Peter Weiss, and John Gulliver from the University of Minnesota and St. Anthony Falls Hydraulic Laboratory. The manual advises on a four-level process to assess the performance of a Best Management Practice.

  • Level 1: Visual Inspection. This includes assessments for infiltration practices and for filtration practices. The website includes links to a downloadable checklist.
  • Level 2: Capacity Testing. Level 2 testing can be applied to both infiltration and filtration practices.
  • Level 3: Synthetic Runoff Testing for infiltration and filtration practices. Synthetic runoff test results can be used to develop an accurate characterization of pollutant retention or removal, but can be limited by the need for an available water volume and discharge.
  • Level 4: Monitoring for infiltration or filtration practices

Level 1 activities do not produce numerical performance data that could be used to obtain a stormwater management credit. BMP owners and operators who are interested in using data obtained from Levels 2 and 3 should consult with the MPCA or other regulatory agency to determine if the results are appropriate for credit calculations. Level 4, Monitoring, is the method most frequently used for assessment of the performance of a BMP.

Use these links to obtain detailed information on the following topics related to BMP performance monitoring:

Additional information on designing a monitoring network and performing field monitoring are found at this link.


Related pages

Links to pages discussing assessment of other BMPs can be found at this page.