Line 27: |
Line 27: |
| <td>Diversion channels/ditches</td> | | <td>Diversion channels/ditches</td> |
| <td> | | <td> |
− | *Most appropriate for short duration projects with low <span title="Baseflow (also called drought flow, groundwater recession flow, low flow, low-water flow, low-water discharge and sustained or fair-weather runoff) is the portion of streamflow delayed shallow subsurface flow". '''baseflows'''</span>. | + | *Most appropriate for short duration projects with low baseflows. |
| *Requires sufficient area in the stream corridor to construct the diversion channel. | | *Requires sufficient area in the stream corridor to construct the diversion channel. |
| *Requires a positive slope to allow flow through the channel. | | *Requires a positive slope to allow flow through the channel. |
Revision as of 22:17, 4 June 2019
Typical diversion methods for working in the dry and their applicability.
Link to this table
Diversion practice |
Applicability |
Limitations |
Partial stream diversion |
- Suitable when work area is on one side of the stream channel or stream bank.
- Appropriate stream size and duration of use depends on materials.
- Structures are placed in the stream to confine flow to one side while work progresses on the “dry” side.
- Sand bags, stone, or similar diversions are appropriate for smaller streams and work areas, while coffer dams, portable dams, or other similar barriers are necessary for larger water bodies.
|
- Not easily moved or adjusted after installation.
- Sand bag or stone in-channel diversions are typically not appropriate for larger streams.
- May be subject to failure or erosion during storm events.
- Results in a smaller area of stream access compared to other diversion methods.
- See Diversion barrier controls (cofferdams/ temporary dikes) for more information
|
Diversion channels/ditches |
- Most appropriate for short duration projects with low baseflows.
- Requires sufficient area in the stream corridor to construct the diversion channel.
- Requires a positive slope to allow flow through the channel.
|
- Not easily moved or adjusted after installation.
- Insufficient flow capacity in pipe can cause diversion failure and severe erosion.
|
Piped diversions/ culverts (bypass pipe) |
- Most appropriate for short duration projects with low baseflows.
- Appropriate when the required flow diversion can be accomplished without pumping.
|
- Construction equipment cannot be driven over pipes.
- Insufficient flow capacity in pipe can cause diversion failure and severe erosion.
|
Pumped diversions (“pump-arounds”) |
- Most appropriate for short duration projects with low baseflows.
- Typically used when there is limited space for a diversion.
- Pump(s) must be sized to accommodate stream baseflow.
|
- Limited by pump capacity, and continuous pumping can be costly.
- Pump failure can result in delays and additional costs.
|