Revision as of 19:45, 13 April 2020

Temporary sediment control: corrective actions
Link to this table

Item Corrective Action Required if Corrective Action1
Storm drain inlet protection
  1. Inlet opening unprotected
  2. Emergency overflow not provided where required
  3. Device not cleaned out
  4. Improper inlet protection for scope of work
  5. Flooding occurring in public use drive lanes
  1. Immediately install inlet control device appropriate to the work
  2. Immediately correct missing overflow condition
  3. Immediately restore function of inlet control device
  4. Immediately correct inlet device for scope of work
  5. Immediately correct flooding condition by changing device or flow constriction

1The number corresponds with the same number in the column "Corrective Action Required"