Line 180: | Line 180: | ||
In addition to establishing a standardized, repeatable methodology for performing routing visual inspections, it is critical to inventory and rank the relative inspection priority of stormwater ponds to ensure ponds with higher likelihood of requiring maintenance are inspected with higher frequency. Development of an inspection prioritization system is discussed further in Section 3.1.2. | In addition to establishing a standardized, repeatable methodology for performing routing visual inspections, it is critical to inventory and rank the relative inspection priority of stormwater ponds to ensure ponds with higher likelihood of requiring maintenance are inspected with higher frequency. Development of an inspection prioritization system is discussed further in Section 3.1.2. | ||
− | + | {{:Inspection skill level descriptions}} | |
[[Inspection action recommendations]] | [[Inspection action recommendations]] |
This page provides guidance related to assessing the total suspended sediment (TSS) and total phosphorus (TP) removal efficiency of permittee owned/operated ponds constructed and used for the collection and treatment of stormwater. Four (4) evaluation strategies are discussed.
The TSS and TP removal efficiency of constructed stormwater ponds degrades over time due to the loss of storage volume to sedimentation and/or sediment phosphorus release. For this reason, it is critical that stormwater ponds be sized correctly for their contributing drainage area and that pond inspection and assessments be performed routinely to monitor sedimentation and identify potential maintenance needs. In addition to evaluating pollutant removal efficiency through comparison to design standards and evaluation of sedimentation, the water quality performance of stormwater ponds can be evaluated using various water quality modeling programs or measured directly through water quality monitoring.
Guidance presented will assist MS4s (Municipal Separate Storm Sewer System) evaluate the TSS and TP treatment effectiveness of ponds post-construction and over their design life. The adjacent table provides a summary of the four (4) TSS and TP removal efficiency evaluation strategies discussed within this memorandum.
TSS and TP Removal Efficiency Evaluation Strategies
Link to this table
Pollutant Removal Assessment Strategy | Description | Relative effort | Relative accuracy |
---|---|---|---|
Evaluation of MPCA stormwater pond design criteria | Evaluation of pond sizing criteria against MPCA stormwater pond design standards to produce a relative evaluation of pond performance | Low | Low |
Stormwater pond inspection/assessment | Guidance related to scheduling and performing routing visual inspections and less-frequent assessments of pond sedimentation depth | Medium/high | NA1 |
Stormwater pond pollutant removal modeling | Evaluation of the pollutant reduction achieved by stormwater ponds through the use of empirically-based or physically-based water quality models | Low/medium | Medium |
Stormwater pond water quality monitoring | Evaluation of the pollutant reduction achieved by stormwater ponds through direct monitoring of pollutant concentrations into and leaving the pond | High | High |
1Stormwater pond inspection/assessment does not inherently provide an estimate of TSS/TP removal. However, inspection/assessment efforts are critical to ensuring a stormwater pond is performing as originally designed.
The MPCA Minnesota Stormwater Manual contains detailed design criteria for many water quality best management practices (BMPs), including constructed stormwater ponds. In addition to outlining construction stormwater pond requirements stipulated by the MPCA Construction General Permit (CGP), the Minnesota Stormwater Manual’s Design Criteria for Stormwater Ponds contains guidance and recommendations related to many aspects of stormwater pond design and construction, from grading and site layout, to overflow spillway design and development of a landscaping plan. Although guidance within the Design Criteria for Stormwater Ponds is primarily focused on requirements related to construction of design of stormwater ponds for new development, elements within the guidance related to sizing of the pond permanent pool volume and live storage water quality volume can be used to evaluate (a) the impact of sedimentation over time and (b) the impact of development and changing land use over time on the water quality performance of existing stormwater ponds. The following subsections outline how design criteria can be used to evaluate the water quality treatment efficiency of existing stormwater ponds and how design criteria can be used to estimate pollutant load reduction.
As discussed in Section 2.0, the Minnesota Stormwater Manual’s Design Criteria for Stormwater Ponds contains guidance and requirements related to the sizing of pond permanent pool volume (Vpp) and live storage water quality volume (Vwq). As defined by the Minnesota Stormwater Manual, the permanent pool (aka, “dead storage”) is the volume of water below the pond outlet, and the water quality volume (aka, “live storage”) is the storage volume between the pond outlet and the pond overflow elevation as shown in Figure 1.
The Minnesota Stormwater Manual’s Design Criteria for Stormwater Ponds outlines minimum requirements for permanent pool volume (Vpp) and water quality volume (Vwq) as outlined by the CGP. Narrative descriptions and resulting equations used to evaluate minimum volume required are outlined below.
The Required minimum permanent pool volume, or dead storage (Vpp), below the outlet elevation), is 1800 cubic feet of storage below the outlet pipe for each acre that drains to the pond
\(V_{pp} = 1800A\)
where
or
\(V_{pp} = 0.0417 A \)
where
The equations and definitions, above, were created for designing and constructing a stormwater pond to treat runoff from new development. Existing stormwater ponds may have larger Vpp than the minimum required by the CGP, or may have larger or smaller Vwq than required. To estimate the water quality performance of existing stormwater ponds, methodology outlined in the Minnesota Stormwater Manual’s MIDS Calculator documentation for stormwater ponds requires the user to evaluate the tributary area to the pond and volume dimension of the pond to determine the “design level” (e.g., Design Level 2) of the pond, and recommends assumed pollutant removal efficiency values based on the design level (e.g., 84% TSS removal for Design Level 2). Criteria for each MIDS stormwater pond design level are summarized in Table 2.
MIDS Calculator stormwater pond design level criteria related to pond volume
Link to this table
MIDS Stormwater Pond Design Level1 | Permanent Pool Volume (Vpp), ft3 | Water Quality Volume (Vwq), ft3 | Pollutant reduction (%)2 | |||
---|---|---|---|---|---|---|
TSS | TP | PP | DP | |||
Design Level 1 | ≥ 1,800 ft3 per acre of tributary area | <= 1 inch from impervious area | 60 | 34 | 62 | 0 |
Design Level 2 | <= 1 inch from impervious area | 84 | 50 | 84 | 8 | |
Design Level 3 | <= 1.5 inch from impervious area | 90 | 60 | 90 | 23 |
1From MIDS Calculator documentation for stormwater ponds. Note: the table summarizes design-level criteria related to permanent pool volume and water quality volume. The complete list of criteria for each design level is summarized on the MIDS calculator
website linked above.
2 TSS = total suspended solids; TP = total phosphorus; PP = particulate phosphorus; and DP = dissolved phosphorus. Pollutant
reduction values cited assume no upstream treatment within tributary area to pond (i.e., untreated urban runoff).
Steps for summarizing the estimating water quality performance of existing stormwater ponds using methodology outlined in the Minnesota Stormwater Manual’s Design Criteria for Stormwater Ponds and MIDS Calculator documentation for stormwater ponds are outlined, below.
1) Determine the permanent pool volume (Vpp) of the pond – the VPP can be determined through a number of sources, including record drawings, as-builts, and bathymetric survey. Note: before using record drawing or as-built data, a pond assessment (Section 3.0) should be conducted to determine the extent to which sedimentation has reduced the Vpp. If estimating volume from bathymetric contour data, the following equation can be used to calculate volume between any two bathymetric contours. The total bathymetric volume can then be calculated by summing the volume between all available bathymetric contours
\( 𝑽_{𝟏−𝟐} = (𝑨_𝟏 + 𝑨_𝟐)/2 × (𝑬_𝟐 − 𝑬_𝟏) \)
Where,
After calculating the volume between each bathymetric contour, the total bathymetric volume can be calculated by summing the volume calculated between each set of contours
\( ∑ 𝑽_𝒊 = (𝑨_{𝒏+𝟏} + 𝑨_n)/𝟐 × (𝑬_{𝒏+𝟏} − 𝑬_𝒏) \)
If only the area at the bottom of the pond (App) and the area at the permanent pool of the pond (Abot) is known, the bathymetric volume can be calculated using the simplified equation
\( ∑ 𝑽_{bathymetric} = (𝑨_{pp} + 𝑨_{bot})/𝟐 × (𝑬_{pp} − 𝑬_{bot}) \)
Where
2) Determine the water quality volume (Vwq) of the pond – as shown in Figure 1, the Vwq is the volume between the ponds permanent pool and the natural or designed overflow elevation. The Vwq can be determined through a number of sources, including record drawings, as-builts, survey data, and surface LiDAR data. A rough estimate of Vwq can be calculated by determining the permanent pool area and the area at the natural or designed overflow elevations. Equation 3, above, can then be used using these two elevations and areas.
3) Evaluate the Vpp of the pond – determine the CGP required Vpp based on the total drainage area to the stormwater pond using Equation 1, above (i.e., 1,800 ft3 per acre of drainage area). If the Vpp is greater than 1,800 ft3, proceed to step 4. If the Vpp of the pond is less than 1,800 ft3 per acre of drainage area, guidance within the Minnesota Stormwater Manual suggests that the pond should not be included in site pollutant removal calculations, as the pond is unlikely to provide adequate treatment. To estimate the water quality performance of a stormwater pond not meeting minimum Vpp requirements, calculations in the following steps can proceed by using only the area for which the Vpp is sized to adequately treat (i.e., Vpp ÷ 1,800 ft3 /acre = treated area (acres)). The remaining portion of the total drainage area to the pond would then be assumed to bypass (i.e., 0% treatment). Alternatively, water quality performance of undersized stormwater ponds can be evaluated through modeling (Section 4.0) or monitoring (Section 5.0).
4) Evaluate the tributary impervious area to the pond – for small sites (e.g., developments less than two acres, etc.), impervious area can be determined through manual evaluation of site impervious cover from record drawings or site plans. For larger drainage stormwater ponds with larger drainage areas (e.g. regional stormwater ponds with drainage areas greater than five acres), land use datasets can be used to estimate total impervious area within the ponds drainage area. The Minnesota Geospatial Information Office (MnGeo) maintains a database of current and historic land use which can be used to evaluate land use and estimate impervious area. Additionally, the University of Minnesota (UMN) provides land cover and impervious data at varying resolution statewide and for specific regions throughout Minnesota (e.g. Twin Cities Metro, Duluth, Rochester, etc.).
5) Determine the impervious area treatment depth in the pond Vwq – using the pond Vwq (Step 2) tributary impervious area (step 4), calculate the impervious area treatment depth using Equation 4, below. Note: Equation 4 is the same as Equation 2 but rearranged to calculate the impervious area treatment depth provided by the pond Vwq.
\( 𝑫_𝒊 = 𝑽_𝒘 𝑨_𝒊 × 𝟏_{𝒊𝒇} \)
Where
6) Determine the MIDS pond design level and corresponding pollutant reduction (%) – after confirming the Vpp is greater than 1,800 ft3 per tributary acre (Step 3) and determining the impervious area treatment depth in the Vwq (Step 5), reference Table 2 to determine the MIDS pond design level (e.g., Design Level 2) and corresponding pollutant reduction (e.g. 84% TSS reduction). Note: pollutant reduction values (%) included in Table 2 assume no upstream water quality BMPs in the tributary area to the stormwater pond (i.e., untreated stormwater runoff). If BMPs within the watershed to the stormwater pond provide significant treatment (e.g., 50% of the tributary area passes through a large infiltration basin before discharging to the stormwater pond), water quality performance should instead be evaluated through modeling (Section 4.0) or monitoring (Section 5.0).
7) Determine influent pollutant loading and pollutant load reduction (lbs) – after determining the pond level design pollutant removal efficiency (%) from Table 2, annual pollutant mass removal (e.g., pounds to TSS removal per year) can be determined by applying the pollutant removal efficiency (%) to the annual influent pollutant mass load. Methodology for determining the annual influent pollutant mass load to the stormwater pond and calculating the pollutant mass removal within the stormwater pond is discussed in Section 2.2.
To estimate the pollutant mass reduction (e.g., pounds of TSS removal per year) in an existing stormwater pond, it is first critical to determine the annual pollutant mass load from the tributary watershed to the stormwater pond. One method of estimating annual pollutant export associated with runoff from a watershed is the Simple Method (Schueler, 1987; CWP & CSN, 2008). The Simple Method is utilized by many annualized water quality models (e.g., the MPCA Simple Estimator spreadsheet model, see Section 4.0) and is a recommended method for calculating credits for stormwater ponds in the Minnesota Stormwater Manual. The Simple Method equation is shown below (Equation 5), followed by steps for determining Simple Method parameter inputs, calculating annual pollutant loading, and calculating annual pollutant reduction
\( 𝑳_{annual} = 𝟎.𝟐 × 𝑨 × 𝑷 × 𝑷_𝒋 × 𝑹_𝒗 × 𝑬MC_{𝒑ollutant} \)
Where
Pj = fraction of rainfall events that produce runoff (default value of 0.9);
1) Determine Simple Method input parameters – the following defines each Simple Method input parameter and provides a summary of how to determine or estimate each parameter:
Note: average annual precipitation depth within the state of Minnesota by zip code can be determined using the MIDS Calculator.
and impervious fraction is provided in Section 2.1, Step 4. Alternatively, the area-weighted watershed Rv value can be calculated using the land use-based Rv values from the MPCA Simple Estimator shown in Table 3.
\( 𝑹_𝒗 = 𝟎.𝟎5 + 𝟎𝟎9 × 𝑰 \)
Where,
MPCA Simple Estimator: Rv, TSS EMC, and TP EMC Values for Land Use Types
Link to this table
Land use | Runoff coefficient (Rv)1 | Event mean concentration (EMC)(mg/L) | |
---|---|---|---|
Total phosphorus (TP) | Total suspended solids (TSS) | ||
Commercial | 0.8 | 0.200 | 75 |
Industrial | 0.8 | 0.235 | 93 |
Institutional | 0.75 | 0.25 | 80 |
Mixed use | 0.5 | 0.290 | 76 |
Open space | 0.2 | 0.190 | 21 |
Residential | 0.4 | 0.325 | 73 |
Transportation | 0.8 | 0.280 | 87 |
1Runoff coefficients vary with soil and slope. Link here
2) Calculate annual pollutant load reduction – after calculating the annual pollutant loading to the stormwater pond (Step 1), the stormwater pond annual pollutant mass load reduction (e.g., pounds of TSS removed per year) can be calculated using the equation, below
\( 𝑹_{annual} = 𝑳_{annual} × 𝑷R_{pollutant} \)
Where, Rannual = annual pollutant load reduction (e.g. pounds of TSS removed per year, lbs TSS/yr); Lannual = annual pollutant load to the stormwater pond (e.g., pounds of TSS per year, lbs TSS/yr); and PRpollutant = pollutant reduction efficiency of the stormwater pond (%). Note: determination of pollutant reduction efficiency is discussed in Section 2.1.
The MPCA stormwater pond design criteria described in Section 2.0 is a simplified methodology used to provide an estimate of stormwater pond water quality performance when other, more accurate methods (see methods listed in Table 1) are not feasible. The following list summarizes limitations of the MPCA stormwater pond design criteria methodology:
As discussed in Section 1.0, the pollutant removal efficiency of constructed stormwater ponds degrades over time due to the loss of storage volume to sedimentation. Additionally, routine maintenance issues (e.g., pond outlet trash rack clogged with debris after storm; sand bar formation at inlet(s); etc.) can significantly reduce the hydraulic and water quality performance of stormwater ponds. For this reason, the municipal separate storm sewer system (MS4) General Permit requires permittees to: a) Perform routine visual inspection of structural BMPs (i.e., inspection), and b) Develop procedures and a schedule to determining the total suspended solids (TSS) and total phosphorus (TP) treatment effectiveness of all municipally owned/operated stormwater ponds (i.e., assessment) (MS4 General Permit Part III.D.6.), including evaluation of sedimentation.
For the purposes of evaluating the pollutant removal efficiency of stormwater ponds, “inspection” is defined as all components of routine visual inspection (Section 3.1). This typically involves walking the pond perimeter, inspecting outlets, and looking for signs of sedimentation and potential maintenance needs (e.g., clogged outlet).
A stormwater pond “assessment” encompasses all activities related to determining the total suspended solids (TSS) and total phosphorus (TP) treatment effectiveness of permittee owned and operated stormwater ponds (Section 3.2). As outlined by the MS4 General Permit, this involves developing procedures to evaluate TSS and TP treatment effectiveness, including development of a schedule for completing assessments of all municipal owned and operated stormwater ponds. Because the pollutant removal efficiency of a stormwater pond can be reduced as permanent pool volume is lost to sedimentation, a pond assessment should include an evaluation of sediment accumulation within the pond. Guidance in Sections 2.0, 4.0, and 5.0 provides methods for estimating, modeling, and directly monitoring the TSS and TP removal efficiency of ponds, respectively, but do not provide guidance on evaluating the permanent pool volume lost to sedimentation. For this reason, the assessment subsection (Section 3.2) provides guidance on how to estimate and directly measure sedimentation volume.
The following subsections provide guidance and recommendations related to the development of inspection and assessment procedures for stormwater ponds.
Although the MS4 General Permit requires annual inspection of structural BMPs (Part III.D.E), the permit makes special exception for stormwater ponds, requiring only one (1) inspection of all ponds and outfalls prior to the expiration date of the permit. Due to critical hydraulic, water quality, and flood protection functions of stormwater ponds, it is recommended that inspection plans be developed to ensure that that:
1) Visual inspection of all municipal stormwater ponds and associated inlets and outlets occurs at least once per year; and that 2) Additional visual inspections are performed as needed in response to large storms (e.g., a rainfall event greater than 2 inches).
Developing a visual inspection standard operating procedure (SOP) for stormwater ponds is critical for ensuring that visual inspections are carried out in a standardized and repeatable fashion. Standardization allows results of inspections from different ponds to be compared to assess relative priority of inspection and maintenance needs, and repeatability allows results of inspections of the same pond to be tracked year to year to evaluate how condition of the stormwater pond has changed. In addition to allowing for evaluation of inspection prioritization (discussed further in Section 3.1.2), an inspection SOP checklist also increases the efficiency and effectiveness of inspectors / municipal operators while performing routing visual inspections.
Although there are many examples for visual inspection SOP checklists which can be used as templates for designing a stormwater pond inspection SOP (see example in Appendix A), it is recommended that an individual use these documents as templates and revise as needed based on conditions within the MS4 (e.g., number of stormwater ponds managed, staff availability and skills, etc.). The following list outlines specific recommendations that should be included or considered in the development of a visual inspection SOP for stormwater ponds:
typically not conducted during routine visual assessment, but signs of sedimentation/changes in sedimentation observed during visual inspection can indicate need to perform an assessment of pond sedimentation (Section 3.2).
An example of a stormwater pond visual inspection SOP checklist from the EPA’s Stormwater Wet Pond and Wetland Management Guidebook (USEPA, 2019) is included in Appendix A. In addition to providing a detailed inspection checklist, the guidebook outlines detailed recommendations related to recommended frequency of pond inspection and maintenance. Adapted from the guidebook (USEPA, 2019), Table 5 and Table 6 outline the inspection operator skill level required and recommended frequency for various inspection tasks. Note: some inspection tasks outlined in Table 6 are in excess of the once annual visual inspection recommendation outlined in this memorandum, and are included to provide context and frequency recommendations for a wide range of inspection actions which should be considered based on factors unique to the MS4 (e.g., number of ponds managed, staff availability and qualifications, etc.) when developing a stormwater pond inspection SOP.
In addition to establishing a standardized, repeatable methodology for performing routing visual inspections, it is critical to inventory and rank the relative inspection priority of stormwater ponds to ensure ponds with higher likelihood of requiring maintenance are inspected with higher frequency. Development of an inspection prioritization system is discussed further in Section 3.1.2.
Inspection skill level descriptions (Source (adapted): USEPA Stormwater Wet Pond and Wetland Management Guidebook (USEPA, 2019).)
Link to this table
Inspection skill level | Definition |
---|---|
0 (low) | No special skills or prior experience required, but some basic training via manual, video, or other materials is necessary. |
1 | Inspector, maintenance crew member or citizen with prior experience with ponds and wetlands |
2 | Inspector or contractor with extensive experience with pond and wetland maintenance issues |
3 (high) | Professional engineering consultant required. |
Inspection action recommendations
Due to the need for routine inspection, if an inventory of all stormwater ponds is available (as required by MS4 General Permit Part III.C.2), it is recommended that MS4s develop an inspection prioritization list for all municipal stormwater ponds. The purpose of an inspection prioritization list is to help ensure that ponds likely to have maintenance needs are inspected annually, and to help identify ponds with lower maintenance needs which may be inspected less frequently (e.g., once every two years). Note: this recommendation is targeted at MS4s responsible for inspection of many stormwater ponds and wetlands, where annual inspection may not be feasible for all ponds. For MS4s with a small number of stormwater ponds or staff availability and resources to perform annual inspection on all stormwater ponds, annual inspection is recommended and inspection prioritization may not be necessary.
After establishment of an, inspection program using a standardized stormwater pond inspection SOP checklist (see Section 3.1.1), inspection prioritization can be ranked using results of inspection SOP worksheets, including quantitative metrics used to rank maintenance needs. An example of ranking categories and associated inspection frequency is shown in Table 7. Note: ranking categories and the inspection frequency assigned to each can be highly dependent on conditions unique to the MS4 (e.g., number of stormwater ponds managed, staff availability, etc.). For this reason, the categories and recommendations provided in Table 7 are meant to serve only as an example of one method of inspection prioritization.
Example of inspection prioritization categories
Prior to the establishment of a routine visual inspection program (Section 3.1.1), other metrics related to the potential pollutant loading and hydraulic function of MS4 stormwater ponds can be used to create an inspection prioritization list. Prior to establishing a database of visual inspection metrics, it is recommended that any or all of the following metrics be used to create a ranked prioritization list, as available:
may require delineation using available stormsewer infrastructure data and topography.