m
m
Line 109: Line 109:
 
<td>89.3</td>
 
<td>89.3</td>
 
<td>86.1</td>
 
<td>86.1</td>
<td>79.2 - 81.1</td>
+
<td>81.1<sup>2</sup></td>
 
<td>89.3</td>
 
<td>89.3</td>
 
</tr>
 
</tr>
Line 217: Line 217:
 
</td>
 
</td>
 
<tr>
 
<tr>
<td colspan=14><font size=1><sup>1</sup> Only data meeting TAPE inflow requirements was available.</font size></td>
+
<td colspan=14><font size=1><sup>1</sup> Only data meeting TAPE inflow requirements was available.</font size>,br>
 +
<sup>2</sup> Six outflow concentrations were at the reporting level of 2.5 mg/L; we used half the reporting limit in our analysis</td>
 
</tr>
 
</tr>
 
</table>
 
</table>

Revision as of 15:42, 23 November 2021

Data summary for manufactured treatment devices
Link to this table

Manufactured treatment device Median inflow TP (mg/L) Median inflow TSS (mg/L) TP Removal (%) TSS removal (%)
Number samples All data TAPE analysis All data TAPE analysis
All data Meeting TAPE criteria Median Mean LCL TAPE median TAPE LCL Median Mean LCL TAPE median
Filterra 0.090 43.5 22 10 67.0 60.1 52.2 78.5 69.2 89.5 86.2 82.8 89.3
Bioscape - see Filterra
Phosphosorb 0.280 389 17 16 81.5 77.4 70.0 78.7 63.6 91.6 88.1 91.6 84.8
Up-Flo 0.109 29 24 13 43.1 32.1 19.1 57.1 49.9 75 67.6 59.9 77.5
Modular wetland 0.103 44 27 16 62.1 60.2 52.7 63.3 54.0 81.9 76.6 71.2 82.9
BayFilter1 0.160 53 11 10 68.6 64.0 59.4 68.6 58.2 89.3 86.1 81.12 89.3
StormGarden 0.078 29 22 15 58.7 56.3 51.6 58.9 43.2 89.2 86.0 82.8 91.9
BioPod 0.104 40 13 7 71.7 66.7 59.5 75.4 62.4 83.3 86.5 82.1 91.9
FloGard 0.123 62.5 22 15 63.6 60.1 50.7; 55.4 without outlier 70.7 48.8 (60.6 without outlier) 80.6 74.7 68.5 81.1
Kraken 0.142 53 13 10 82.7 74.8 67.1 83.6 71.3 90.6 87.4 77.5 90.7
Jellyfish 0.338 134 21 18 75.2 73.6 68.2 71.0 66.8 86.2 80.0 74.1 78.4
Media Filtration System Though this device is GULD certified, it is not used in Minnesota. We therefore did not analyze the data.
Stormfilter using ZPG Media Though this device is GULD certified, it is not used in Minnesota. We therefore did not analyze the data.
ecoStorm plus
1 Only data meeting TAPE inflow requirements was available.,br> 2 Six outflow concentrations were at the reporting level of 2.5 mg/L; we used half the reporting limit in our analysis