m |
PKalinosky (talk | contribs) m |
||
Line 99: | Line 99: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td>BMP located less than 200 feet from | + | <td>BMP located less than 200 feet from crest of slope that exceeds 20%</td> |
<td></td> | <td></td> | ||
<td>X</td> | <td>X</td> |
Summary of situations where infiltration of stormwater runoff is prohibited or not recommended.
Link to this table
Condition | Prohibited | Not recommended | Not recommended unless conditions are met1 |
---|---|---|---|
Local rule or ordinance prohibits infiltration | X | ||
BMP is < 100 feet from drinking well in sensitive aquifer3 | X | ||
BMP is < 50 feet from drinking well in a non-sensitive aquifer3 | X | ||
BMP receives discharges from vehicle fueling and maintenance areas | X | ||
There is less than 3 of separation to bedrock or saturated soil | if CGP applies2 | X | |
BMP receives discharges from certain industrial facilities4 | if CGP applies | ||
BMP is in areas where high levels of contaminants in soil or groundwater will be mobilized by the infiltrating stormwater | if CGP applies | X | |
BMP is located in D soils | if CGP applies | X | |
BMP is 1,000 feet up-gradient or 100 feet down-gradient of active karst | if CGP applies | X | |
BMP is located within an Emergency Response Area in a DWSMA exhibiting high or very high vulnerability | if CGP applies | X | |
BMP is located within an Emergency Response Area (ERA) in a DWSMA exhibiting moderate vulnerability, or outside an ERA in a DWSMA exhibiting high or very high vulnerability | if CGP applies, unless a higher engineering review indicates infiltration is acceptable | X | |
BMP is located in soils with infiltration rate > 8.3 in/hr | if CGP applies | X | |
BMP is located within 1 year travel time of drinking supply well | X | ||
BMP located within 10 feet of building or structure | X | ||
BMP located within 35 feet of a septic system | X | ||
BMP located less than 200 feet from crest of slope that exceeds 20% | X | ||
BMP receives discharges from a confirmed stormwater hotspot | X | ||
A groundwater mound formed beneath the BMP during infiltration extends into the BMP | X |
1see discussion for conditions under which infiltration is acceptable.
2CGP = Construction Stormwater General Permit
3See Minnesota Rules Chapter 4725
4To determine if infiltration is allowed for a specific industrial sector or subsector, go to the list of sectors, select the sector of interest, and review section 8 for that sector (Use of Infiltration Devices and/or Industrial Stormwater Ponds for Stormwater Treatment and Disposal)
This page was last edited on 18 January 2024, at 20:17.