Infiltration media and material specifications
Link to this table
Component | Infiltration basin | Bioinfiltration basin | Infiltration trench | Underground infiltration | Dry well | Dry swale with check dams | Permeable pavement | Tree trench/box/planter |
---|---|---|---|---|---|---|---|---|
Observation well | *Vertical 4- to 6-inch Schedule 40 PVC perforated pipe according to MNDOT Manual Section 3248 with a lockable cap and anchor plate within gravel portion of bed.
|
*Vertical 4- to 6-inch Schedule 40 PVC perforated pipe according to MNDOT Manual Section 3248 with a lockable cap and anchor plate within gravel portion of bed.
|
*Vertical 4- to 6-inch Schedule 40 PVC perforated pipe according to MNDOT Manual Section 3248 with a lockable cap and anchor plate within gravel portion of bed.
|
|||||