Summary of water reuse criteria for select nonpotable applications from reuse programs from several statesa
Link to this table
Water Quality Parameter | Water Quality Limit – Food Crop Irrigation | Water Quality Limit – Restricted Access Irrigation | Water Quality Limit – Unrestricted Access Irrigation |
---|---|---|---|
Total Coliform | 2.2 total coliform | 23 total coliform/100mL | 2.2 total coliform/100mL |
Fecal Coliform | No Detect/100mL (some states prohibit usea) | 200 fecal coliform/100mL | No Detect/100mL – 20 fecal coliform/100mL |
E. coli | N/A | 126 E. coli/100mL (only CO uses E. coli as a standard) | 126 E. coli/100mL (only CO uses E. coli as a standard) |
Turbidity | 2 NTU | N/A | 2 NTU – 3 NTU |
TSS | N/A | 20-30 mg/L | 5 mg/L |
BOD | 10 mg/L BOD | 20-30 mg/L | 5-10 mg/L |
CBOD | N/A | 15-20 mg/L | 5-20 mg/L |
pH | N/A | N/A | N/A |
Note: Many of these standards are based on water quality limits established for reclaimed water (treated wastewater), not stormwater specifically
a – Includes review of water reuse programs in AZ, CA, CO, FL, GA, HI, NV, NM, NC, OR, TX, UT, WA, and US EPA guidelines