Data summary for manufactured treatment devices
Link to this table
Manufactured treatment device | Median inflow TP (mg/L) | TP Removal (%) | TSS removal (%) | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Median | Mean> | LCL | TAPE median | TAPE LCL | Median | Mean> | TAPE median | LCL | ||
Filterra | 0.09 | 67 | 60.1 | 52 | 78.5 | 69.4 | 89.5 | 86.2 | 91 | 82.8 |
Phosphosorb | 0.28 | 81.5 | 77.4 | 69.7 | 81.5 | 69 | 91.6 | 88.1 | 84.8 | 91.6 |
Up-Flo | 0.11 | 43.1 | 32.1 | 19.1 | 57.1 | 49.9 | 75 | 67.6 | 77.5 | 59.9 |
Modular wetland | 0.1 | 61.3 | 60.2 | 58.8 | 63.3 | 54.1 | 81.9 | 76.6 | 82.9 | 71 |