Data summary for manufactured treatment devices
Link to this table

<StormGarden
Manufactured treatment device Median inflow TP (mg/L) TP Removal (%) TSS removal (%)
Median Mean LCL TAPE median TAPE LCL Median Mean TAPE median LCL
Filterra 0.09 67 60.1 52 78.5 69.4 89.5 86.2 91 82.8
Phosphosorb 0.28 81.5 77.4 69.7 81.5 69 91.6 88.1 84.8 91.6
Up-Flo 0.11 43.1 32.1 19.1 57.1 49.9 75 67.6 77.5 59.9
Modular wetland 0.1 61.3 60.2 58.8 63.3 54.1 81.9 76.6 82.9 71
BayFilter1 68.6 59.4 89.3 87.4
0.078 58.7 56.3 58.9 57.5 89.2 86.0 91.9 82.8

1 Only data meeting TAPE inflow requirements was available.