Percent P Removed Via Non-Volume Reduction Treatment
Link to this table
Particulate P | Dissolved P | |||
---|---|---|---|---|
Current | Proposed | Current | Proposed | |
No underdrain | 0% | 0% | 0% | 0% |
Elevated underdrain | 45% | Is soil P content tested to be < 36 mg/kg per Mehlich III test?
If yes, 40 % If no, 0% |
0% | Is soil P content tested to be < 36 mg/kg per Mehlich III test?
If no, 0% If yes, is there at least 2 feet of soil above the elevated underdrain? If yes, 20% credit, If no, credit = 0.2*x Where x = (soil depth above elevated underdrain) /2’ Credit for approved P-sorbing soil amendments*? For iron enhanced soils, Imbrium or WTRs, additional 40% credit |
Underdrain at the bottom | 91% | Is soil P content tested to be < 36 mg/kg per Mehlich III test?
If yes, 40 % If no, 0% |
0% | Is soil P content tested to be < 36 mg/kg per Mehlich III test?
If yes, 20 % If no, 0% Does the system include approved P-sorbing soil amendments*? For iron enhanced soils, Imbrium or WTRs, additional 40% credit |
Internal Water Storage (IWS) | Is soil P content tested to be < 36 mg/kg per Mehlich III test?
If yes, 40 % If no, 0% |
Is soil P content tested to be < 36 mg/kg per Mehlich III test?
If yes, 20 % If no, 0% Does the system include approved P-sorbing soil amendments*? For iron enhanced soils, Imbrium or WTRs, additional 40% credit |
Approved P sorption amendments: