m |
m |
||
Line 8: | Line 8: | ||
{{:Determination of Appropriate Monitoring Level(s) for a Stormwater Treatment Practice}} | {{:Determination of Appropriate Monitoring Level(s) for a Stormwater Treatment Practice}} | ||
+ | |||
+ | ==Filter Media Capacity Testing== | ||
+ | Assessing Filter Media consists of collection and analysis of filter media for iron, soluble reactive phosphorus and total phosphorus to estimate remaining service life of the media. Current research is designed to enable a relationship between filter media iron and phosphorus in samples and the remaining life of the IESF. | ||
+ | Water sampling: Total phosphorus at the outlet of the iron-sand filter that consistently exceeds 60 to 70 micrograms per liter may be used as an indicator that the phosphorus binding capacity of the iron-enhanced sand bed has been consumed. If this condition is true, then it is recommended that samples be taken from the iron-sand bed and analyzed for total phosphorus and total iron. NOTE: Poor phosphate capture can also indicate short-circuiting or bypass of the IESF media. Capacity testing, synthetic runoff testing, or monitoring can be used to determine if short-circuiting is the cause of poor performance. | ||
+ | Media: Take two samples of the IESF media at five roughly evenly-spaced locations throughout the media; the first sample at mid-depth and the second towards the bottom of the media, Total phosphorus to total iron ratios that exceed 5 milligrams of phosphorus per gram of elemental iron (Erickson et al., 2007, 2012) indicate the phosphorus binding capacity of the iron-sand bed is exhausted and should be replaced. | ||
+ | Alternatively, IESF media samples can be used in benchtop batch studies (aka jar tests) to determine whether the media has capacity to capture phosphate. Media samples of a known mass (e.g., 10g) can be added to clean, washed jars of known water volume at known phosphate concentration (e.g., 100-300 µg/L), and then mixed for between 10 minutes and up to 24 hours. Then, water samples from the jars can be collected and analyzed for phosphate concentration. From this data, the phosphate capture capacity can be estimated (Erickson et al., 2018). | ||
+ | |||
+ | ==Monitoring IESFs== | ||
+ | Monitoring is the most comprehensive assessment technique and can be used to assess water volume reduction, peak flow reduction, and pollutant removal efficiency by measuring discharge and pollutant concentration during natural runoff events through flow measurements and water sample analysis. | ||
+ | The two types of monitoring recommended for IESFs are as follows: | ||
+ | #Flow Monitoring, which consists of measurements of the inflow and outflow for the IESF using techniques described in Water Budget Measurement. The sum of inflows and outflows measured at the IESF inlet(s) and outlet(s) is used for mass balance calculations for Level 4 Monitoring. Flow monitoring allows for calculation of filtration rate, ponding duration, and rate control. | ||
+ | #Pollutant Removal, which consists of water sample collection from the IESF inlet(s) and outlet(s) for analysis of concentration of pollutants of concern. Four methods of sampling (in situ, on-site, grab, and automatic) are described in Sampling Methods. Paired with flow monitoring, analysis of pollutant concentrations allows for the calculation of pollutant load removal, as detailed in Data Analysis for Monitoring for both individual storm events and long-term monitoring. The recommended monitoring parameters for IESFs are TSS, soluble reactive phosphorus and total phosphorus. | ||
+ | |||
+ | ==Stormwater Pollution Reduction Credits== | ||
+ | Monitoring your IESF may qualify your practice for stormwater pollution reduction credits, depending on the level of monitoring and consultation with the MPCA. | ||
+ | |||
+ | ==References and additional information== | ||
+ | Use these links to obtain detailed information on the following topics related to BMP performance monitoring: | ||
+ | *[http://stormwaterbook.safl.umn.edu/developing-assessment-program Developing an Assessment Program] | ||
+ | *[https://stormwaterbook.safl.umn.edu/water-budget-measurement Water Budget Measurement] | ||
+ | *[https://stormwater.pca.state.mn.us/index.php/MIDS_calculator Determination of Filter Service Life] | ||
+ | *[https://stormwaterbook.safl.umn.edu/sampling-methods Sampling Methods] | ||
+ | *[https://stormwaterbook.safl.umn.edu/analysis-water-and-soils Analysis of Water and Soils] | ||
+ | *Analysis of Filter Media | ||
+ | *[https://stormwaterbook.safl.umn.edu/data-analysis Data Analysis for Monitoring] | ||
+ | |||
+ | Additional information on designing a monitoring network and performing field monitoring [http://stormwater.pca.state.mn.us/index.php/Calculating_credits_for_sand_filter#Credits_based_on_field_monitoring are found at this link]. | ||
+ | |||
+ | '''References''': | ||
+ | *Erickson, A.J., V.J. Taguchi, and J.S. Gulliver. (2018). "The Challenge of Maintaining Stormwater Control Measures: A Synthesis of Recent Research and Practitioner Experience." Journal of Sustainability Special Issue, 10, 3666. http://dx.doi.org/10.3390/su10103666. | ||
+ | *Gulliver, J.S., A.J. Erickson, and P.T. Weiss (editors). 2010. "Stormwater Treatment: Assessment and Maintenance. University of Minnesota, St. Anthony Falls Laboratory. Minneapolis, MN. https://stormwaterbook.safl.umn.edu/ |
Iron-enhanced sand filters (IESFs) retain solids and associated pollutants by filtering and through adsorption of phosphate (soluble reactive phosphorus) from stormwater. A typical method for assessing the performance of BMPs with underdrains is therefore measuring and comparing pollutant concentrations at the influent to the filter and effluent from the underdrain outlet. Before developing an assessment program, it is important to have well-defined goals so that the effort required to develop and implement the program is focused to achieve the desired results. The need for assessment can be determined by permit, voluntary watershed management goals, TMDL allocation, or protection efforts, among others. Rather than proposing a series of rigid procedures, four assessment options are provided below that can be used in various combinations depending on information needs, budgetary constraints, time frames, and legal requirements. An online manual for assessing BMP treatment performance (Gulliver, et al. 2010) advises on a four-level process to assess the performance of a Best Management Practice.
Determination of Appropriate Monitoring Level(s) for a Stormwater Treatment Practice.
Link to this table
Level | When should I perform this assessment? | Advantages | Requirements/limitations | Recommended frequency | Can this be used to obtain a stormwater credit? |
---|---|---|---|---|---|
Visual inspection | Recommended for all practices | Quick and cost-effective | Available personnel. Does not necessarily identify causes of poor performance. | ≥ 1x / year, at start of rainy season | No |
Capacity testing | If there are suspected filtration rate problems with the practice, or to determine if the media has capacity for phosphorus removal | Applicable for practices of all sizes, quickly identify specific areas that require maintenance, less time and expense than monitoring | A Modified Philip-Dunne Infiltrometer is recommended for filtration rate testing. | Every few years | Consult with MPCA (Minnesota Pollution Control Agency) or regulatory agency to determine eligibility |
Synthetic runoff testing | If there are suspected problems with filtration or pollutant removal, or to establish a baseline condition or baseline performance level | Controlled method to accurately measure drawdown time and/or pollutant removal efficiency |
|
Every few years | Consult with MPCA or regulatory agency to determine eligibility |
Monitoring | Goals include obtaining stormwater credits, assessing performance results and life of filter media, or complying with a permit or regulatory agency | Most comprehensive assessment technique and measures the response to natural rainfall events |
|
Continuously from construction of the IESF | Yes |
Assessing Filter Media consists of collection and analysis of filter media for iron, soluble reactive phosphorus and total phosphorus to estimate remaining service life of the media. Current research is designed to enable a relationship between filter media iron and phosphorus in samples and the remaining life of the IESF. Water sampling: Total phosphorus at the outlet of the iron-sand filter that consistently exceeds 60 to 70 micrograms per liter may be used as an indicator that the phosphorus binding capacity of the iron-enhanced sand bed has been consumed. If this condition is true, then it is recommended that samples be taken from the iron-sand bed and analyzed for total phosphorus and total iron. NOTE: Poor phosphate capture can also indicate short-circuiting or bypass of the IESF media. Capacity testing, synthetic runoff testing, or monitoring can be used to determine if short-circuiting is the cause of poor performance. Media: Take two samples of the IESF media at five roughly evenly-spaced locations throughout the media; the first sample at mid-depth and the second towards the bottom of the media, Total phosphorus to total iron ratios that exceed 5 milligrams of phosphorus per gram of elemental iron (Erickson et al., 2007, 2012) indicate the phosphorus binding capacity of the iron-sand bed is exhausted and should be replaced. Alternatively, IESF media samples can be used in benchtop batch studies (aka jar tests) to determine whether the media has capacity to capture phosphate. Media samples of a known mass (e.g., 10g) can be added to clean, washed jars of known water volume at known phosphate concentration (e.g., 100-300 µg/L), and then mixed for between 10 minutes and up to 24 hours. Then, water samples from the jars can be collected and analyzed for phosphate concentration. From this data, the phosphate capture capacity can be estimated (Erickson et al., 2018).
Monitoring is the most comprehensive assessment technique and can be used to assess water volume reduction, peak flow reduction, and pollutant removal efficiency by measuring discharge and pollutant concentration during natural runoff events through flow measurements and water sample analysis. The two types of monitoring recommended for IESFs are as follows:
Monitoring your IESF may qualify your practice for stormwater pollution reduction credits, depending on the level of monitoring and consultation with the MPCA.
Use these links to obtain detailed information on the following topics related to BMP performance monitoring:
Additional information on designing a monitoring network and performing field monitoring are found at this link.
References: