m |
m |
||
Line 1: | Line 1: | ||
− | <font size="3">'''Design restrictions for special | + | <font size="3">'''Design restrictions for special waters - constructed ponds and wetlands'''</font size><br> |
− | Link to this [[Design restrictions for special | + | Link to this [[Design restrictions for special waters - constructed ponds and wetlands|table]] |
<table class="sortable"> | <table class="sortable"> | ||
Design restrictions for special waters - constructed ponds and wetlands
Link to this table
A Lakes |
B Trout Waters |
C Drinking Water* |
D Wetlands |
E Impaired Waters |
|
Constructed wetlands | Some variations NOT RECOMMENDED due to poor P removal, combined with other treatments. | NOT RECOMMENDED except for wooded wetlands |
RECOMMENDED | RECOMMENDED but no use of natural wetlands |
RECOMMENDED |
Wet Extended Detention Pond | RECOMMENDED | Some variations NOT RECOMMENDED due to pool and stream warming concerns | RECOMMENDED | RECOMMENDED (alteration of natural wetlands as stormwater wetlands not allowed) | RECOMMENDED |
*Applies to groundwater drinking source areas only; use the sensitive lakes category to define BMP Design restrictions for surface water drinking supplies