Example sizing information for riprap energy dissipators at culvert outlets
Link to this table
Culvert size Avg. rock diameter Apron width1 Apron length2 Apron length3
8" 3" 2–3 ft. 3–5 ft. 5–7 ft.
12" 5" 3–4 ft 4–6 ft. 8–12 ft.
18" 8" 4–6 ft. 6–8 ft. 12–18 ft.
24" 10" 6–8 ft. 8–12 ft. 18–22 ft.
30" 12" 8–10 ft. 12–14 ft. 22–28 ft.
36" 14" 10–12 ft. 14–16 ft. 28–32 ft.
42" 16" 12–14 ft. 16–18 ft. 32–38 ft.
48" 20" 14–16 ft. 18–25 ft. 38–44 ft.
  • 1Apron width at the narrow end (pipe or channel outlet)
  • 2Apron length for slow-flow (no pressure head) culverts
  • 3Apron length for high flow (pressure head) culverts

Source: Kentucky Division of Water