m
m
Line 19: Line 19:
 
<td>ASTM C-33 fine aggregate concrete sand</td>
 
<td>ASTM C-33 fine aggregate concrete sand</td>
 
<td>0.02” to 0.04”</td>
 
<td>0.02” to 0.04”</td>
<td>   </td>
+
<td> </td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
+
 
 
<td>Check Dam (pressure treated)</td>
 
<td>Check Dam (pressure treated)</td>
 
<td>AWPA Standard C6</td>
 
<td>AWPA Standard C6</td>
Line 50: Line 50:
 
</tr>
 
</tr>
 
<tr>
 
<tr>
<tdUnder-drain gravel</td>
+
<td>Under-drain gravel</td>
 
<td>per pre-cast manufacturer</td>
 
<td>per pre-cast manufacturer</td>
 
<td>1.5” to 3.5”</td>
 
<td>1.5” to 3.5”</td>
<td>   </td>
+
<td> </td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
Line 65: Line 65:
 
<td>See local Standards and Specs</td>
 
<td>See local Standards and Specs</td>
 
<td>n/a</td>
 
<td>n/a</td>
<td>   </td>
+
<td> </td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
Line 71: Line 71:
 
<td>per local criteria</td>
 
<td>per local criteria</td>
 
<td>size per equirements based on 10- year design flow</td>
 
<td>size per equirements based on 10- year design flow</td>
<td>   </td>
+
<td> </td>
 
</tr>
 
</tr>
 
</table>
 
</table>

Revision as of 21:05, 4 February 2013


Open vegetated swale and filter strip materials specifications.
Link to this table
Parameter pecification Size Notes
Dry swale soil USCS; ML, SM, SC n/a soil with a higher percent organic content is preferred
Dry Swale sand ASTM C-33 fine aggregate concrete sand 0.02” to 0.04”
Check Dam (pressure treated) AWPA Standard C6 6” by 6” or 8” by 8” do not coat with creosote; embed at least 3’ into side slopes
Check Dam (natural wood) Black Locust, Red Mulberry, Cedars, Catalpa, White Oak, Chestnut Oak, Black Walnut 6” to 12” diameter; notch as necessary do not use the following, as these species have a predisposition towards rot: Ash, Beech, Birch, Elm, Hackberry, Hemlock, Hickories, Maples, Red and Black Oak, Pines, Poplar, Spruce, Sweetgum, Willow
Filter Strip sand/gravel pervious berm

sand: per dry swale sand

gravel; AASHTO M-43
sand: 0.02” to 0.04” gravel: 1/2” to 1” Mix with approximately 25% loam soil to support grass cover crop; see Bioretention planting soil notes for more detail
Pea gravel diaphragm and curtain drain ASTM D 448 varies (No. 6) or (1/8” to 3/8”) use clean bank-run gravel
Under-drain gravel per pre-cast manufacturer 1.5” to 3.5”
Under-drain ASTM D-1785 or AASHTO M-278 6” rigid Schedule 40 PVC 3/8” perf. @ 6” o.c.; 4 holes per row
Geotextile See local Standards and Specs n/a
Rip rap per local criteria size per equirements based on 10- year design flow