Tree trench performance summary for ultra-urban treatment train scenario.
Link to this table

Event Runoff Volume Performance Summary Event Runoff Volume Performance Summary Small Trench
Runoff Volume from Direct Watershed (ft3) 80 48
Runoff Volume from Upstream BMPs (ft3) 49 0
Retention Volume Provided by BMP (ft3) 419 209
Outflow Volume from BMP (ft3)) 0 0
Percent Performance Goal Achieved (%) 100 100
Annual Performance Goal Summary
Volume Runoff from Direct Watershed (acre-ft.) 0.05 0.03
Runoff from Upstream BMPs (acre-ft.) 0.44 0.00
Retention Volume Provided by BMP (acre-ft.) 0.49 0.03
Outflow Volume from BMP (acre-ft.) 0 0
Percent Performance Goal Achieved (%) 100 100
Phosphorus (P) Particulate P from Watershed (lbs.) 0.02 0.01
Particulate P from Upstream BMPs (lbs.) 0.36 0
Particulate P Load Reduction (lbs.) 0.38 0.01
Particulate P Outflow 0 0
Total Percent Particulate P Reduction 100 100
Dissolved P from Watershed (lbs.) 0.02 0.01
Dissolved P from Upstream BMPs (lbs.) 0.29 0
Dissolved P Load Reduction (lbs.) 0.31 0.01
Dissolved P Outflow (lbs.) 0 0
Total Percent Dissolved P Reduction (%) 100 100
Total Suspended Solids (TSS) TSS from Watershed (lbs.) 7 4
TSS from Upstream BMPs (lbs.) 5 0
TSS Load Reduction (lbs.) 12 4
TSS Outflow (lbs.) 0 0
Total Percent TSS Reduction (%) 100 100