m
m
Line 51: Line 51:
 
<font size=1>Note that the routed method for the 1-year design (R124) is much less than the Instantaneous volume due to the more constricted orifice.</font size>
 
<font size=1>Note that the routed method for the 1-year design (R124) is much less than the Instantaneous volume due to the more constricted orifice.</font size>
  
<noinclude>[[category:Table]]</noinclude>
+
<noinclude>[[category:Pond table]]</noinclude>

Revision as of 18:18, 16 April 2020

Wet detention pond - Channel protection / water quality outlet configuration
Link to this table

Design methodology
1-yr 24-hr Instantaneous volume 1-yr 24-hr routed (R124) 1/2 Pre-development 2-yr 24-hr peak Instantaneous volume 1/2 Pre-development 2-yr 24-hr peak routed (R224)
Orifice diameter (inches) 10.5 6.9 10.0 11.6
Oriface elevation (ft) 105.0 105.0 105.0 105.0
Surface area at orifice elevation (ac) 0.6 0.6 0.6 0.6
Peak discharge per design event (cfs) 6.4 2.1 5.8 5.8
Peak water elevation per design event (ft) 107.9 108.2 108.7 108.5

Note that the routed method for the 1-year design (R124) is much less than the Instantaneous volume due to the more constricted orifice.