m |
m |
||
(17 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | + | <font size=3>'''This table shows a list of BMPs and associated pollutant removal mechanisms. Primary (removal) means the BMP was designed for this specific mechanism. Secondary (removal) means the BMP provides additional removal of pollutants for this mechanism even though the BMP was not designed for that purpose. An empty cell means the BMP provides limited or no removal for that mechanism.'''</font size><br> | |
− | + | Link to this [[Primary and secondary pollutant removal mechanisms|table]]. | |
− | Link to this [[Primary and secondary pollutant removal mechanisms|table]]. | ||
<table class="sortable"> | <table class="sortable"> | ||
<tr> | <tr> | ||
<th rowspan="3"><center>BMP group</center></th> | <th rowspan="3"><center>BMP group</center></th> | ||
− | <th colspan=" | + | <th colspan="6"><center>Pollutant removal mechanisms</center></th> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<th colspan="6"><center>Water quality</center></th> | <th colspan="6"><center>Water quality</center></th> | ||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <th>Filtration</th> | + | <th width="9%">Filtration</th> |
− | <th>Infiltration</th> | + | <th width="9%">Infiltration</th> |
− | <th>Settling</th> | + | <th width="9%">Settling</th> |
− | <th>Biological uptake</th> | + | <th width="9%">Biological uptake</th> |
− | <th>Temperature control</th> | + | <th width="9%">Temperature control</th> |
− | <th>Soil adsorption | + | <th width="9%">Soil adsorption</th> |
− | |||
− | |||
− | |||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Pollution prevention</td> | <td>Pollution prevention</td> | ||
− | <td colspan=" | + | <td colspan="6"><center>Not applicable - pollutants not exposed to stormwater</center></td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Better Site Design/low impact development</td> | <td>Better Site Design/low impact development</td> | ||
− | <td> | + | <td>primary</td> |
− | + | <td>secondary</td> | |
− | + | <td>secondary</td> | |
− | + | <td>secondary</td> | |
− | + | <td>secondary</td> | |
− | <td> | + | <td>secondary</td> |
− | <td> | ||
− | <td> | ||
− | <td> | ||
− | <td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Runoff volume minimization</td> | <td>Runoff volume minimization</td> | ||
<td></td> | <td></td> | ||
− | <td> | + | <td>secondary</td> |
− | |||
− | |||
− | |||
<td></td> | <td></td> | ||
− | |||
− | |||
<td></td> | <td></td> | ||
+ | <td>secondary</td> | ||
<td></td> | <td></td> | ||
</tr> | </tr> | ||
Line 58: | Line 44: | ||
<td></td> | <td></td> | ||
<td></td> | <td></td> | ||
− | <td> | + | <td>primary</td> |
− | |||
− | |||
<td></td> | <td></td> | ||
<td></td> | <td></td> | ||
− | |||
− | |||
<td></td> | <td></td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Bioretention</td> | <td>Bioretention</td> | ||
− | <td> | + | <td>primary</td> |
− | <td> | + | <td>secondary</td> |
− | <td> | + | <td>secondary</td> |
− | <td> | + | <td>secondary</td> |
− | <td> | + | <td>secondary</td> |
− | <td> | + | <td>secondary</td> |
− | |||
− | |||
− | |||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Filtration</td> | <td>Filtration</td> | ||
− | <td> | + | <td>primary</td> |
− | <td> | + | <td>secondary</td> |
− | |||
− | |||
<td></td> | <td></td> | ||
− | <td> | + | <td>secondary</td> |
<td></td> | <td></td> | ||
− | <td> | + | <td>secondary</td> |
− | |||
− | |||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Infiltration</td> | <td>Infiltration</td> | ||
− | <td> | + | <td>secondary</td> |
− | + | <td>primary</td> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | <td></td> | ||
<td></td> | <td></td> | ||
+ | <td>secondary</td> | ||
+ | <td>primary</td> | ||
+ | <td>secondary</td> | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>Stormwater ponds</td> | <td>Stormwater ponds</td> | ||
<td></td> | <td></td> | ||
− | <td> | + | <td>secondary</td> |
− | <td> | + | <td>primary</td> |
− | + | <td>secondary</td> | |
− | <td></td> | ||
<td></td> | <td></td> | ||
<td></td> | <td></td> | ||
− | |||
− | |||
− | |||
</tr> | </tr> | ||
+ | <tr> | ||
<td>Stormwater wetlands</td> | <td>Stormwater wetlands</td> | ||
− | <td> | + | <td>secondary</td> |
− | <td> | + | <td>secondary</td> |
− | <td> | + | <td>primary</td> |
− | <td> | + | <td>primary</td> |
<td></td> | <td></td> | ||
− | <td> | + | <td>secondary</td> |
− | + | </tr> | |
− | |||
− | |||
− | |||
<tr> | <tr> | ||
<td>Supplemental treatment</td> | <td>Supplemental treatment</td> | ||
− | <td colspan=" | + | <td colspan="6"><center>Each supplemental and proprietary device should be carefully studied to learn the primary and secondary removal functions</center></td> |
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | <noinclude> | ||
+ | [[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Pollutant removal]] | ||
+ | </noinclude> |
This table shows a list of BMPs and associated pollutant removal mechanisms. Primary (removal) means the BMP was designed for this specific mechanism. Secondary (removal) means the BMP provides additional removal of pollutants for this mechanism even though the BMP was not designed for that purpose. An empty cell means the BMP provides limited or no removal for that mechanism.
Link to this table.
Filtration | Infiltration | Settling | Biological uptake | Temperature control | Soil adsorption | |
---|---|---|---|---|---|---|
Pollution prevention | ||||||
Better Site Design/low impact development | primary | secondary | secondary | secondary | secondary | secondary |
Runoff volume minimization | secondary | secondary | ||||
Temporary construction sediment control | primary | |||||
Bioretention | primary | secondary | secondary | secondary | secondary | secondary |
Filtration | primary | secondary | secondary | secondary | ||
Infiltration | secondary | primary | secondary | primary | secondary | |
Stormwater ponds | secondary | primary | secondary | |||
Stormwater wetlands | secondary | secondary | primary | primary | secondary | |
Supplemental treatment |
This page was last edited on 15 December 2022, at 02:54.