<font size=1>Reference links: [http://www.iowadnr.gov/Portals/idnr/uploads/water/stormwater/manual/iswmm_chapter11.pdf?ver=2016-04-12-161256-770 1]; [https://www.njstormwater.org/pdf/FDHC_Certification_2017-03-09.pdf 2]; | <font size=1>Reference links: [http://www.iowadnr.gov/Portals/idnr/uploads/water/stormwater/manual/iswmm_chapter11.pdf?ver=2016-04-12-161256-770 1]; [https://www.njstormwater.org/pdf/FDHC_Certification_2017-03-09.pdf 2]; | ||
[http://www.imbriumsystems.com/stormwater-treatment-solutions/stormceptor-systems 3]; [http://www.njcat.org/uploads/newDocs/BarracudaVerificationReportFinal.pdf 4]; | [http://www.imbriumsystems.com/stormwater-treatment-solutions/stormceptor-systems 3]; [http://www.njcat.org/uploads/newDocs/BarracudaVerificationReportFinal.pdf 4]; | ||
− | [https://oldcastleinfrastructure.com/product/dual-vortex-separator-dvs-square/ 5]; [https://biocleanenvironmental.com/sciclone | + | [https://oldcastleinfrastructure.com/product/dual-vortex-separator-dvs-square/ 5]; [https://biocleanenvironmental.com/sciclone-separator 6]</font size> |
+ | |||
+ | <noinclude> | ||
+ | [[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Pollutant removal]] | ||
+ | [[Category:Level 3 - Best management practices/Pretreatment practices/Tables]] | ||
+ | [[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Pretreatment]] | ||
+ | </noinclude> |
Hydrodynamic separation devices - pollutant removal characteristics
Link to this table
Proprietary devices | Primary mechanism | Secondary mechanism | Other mechanism | Pollutants removed |
---|---|---|---|---|
Vortechs TM by Contech1 | Hydrodynamic separation | Settling | Buoyancy/Skimming | Sediment, particulates > 50 microns, floatables |
Continuous Deflective Separation (CDS) R by Contech1 | Hydrodynamic separation | Settling/straining | Buoyancy/Skimming | Sediment, trash, floatables |
Downstream Defender TM H.I.L. Technology1 | Hydrodynamic separation | Settling | Buoyancy/Skimming | Particles >150 microns, floatables, oil and grease |
First Defense R by Hydro International2 | Hydrodynamic separation | Settling | Buoyancy/Skimming | Total suspended solids, sediment, trash, hydrocarbons, oil and grease |
Stormceptor R by Imbrium or Rinker Materials3 | Hydrodynamic separation | Settling | Buoyancy/Skimming | Sediment, oil and grease |
Barracuda by BaySaver4 | Hydrodynamic separation | Settling | Total suspended solids | |
Dual Vortex Separator by OldCastle5 | Hydrodynamic separation | Settling | Total suspended solids, gross solids, trash, debris, oil and grease | |
SciClone TM by BioClean6 | Hydrodynamic separation | Buoyancy/skimming | Total suspended solids, trash, oil and grease |