(Created page with "<font size=3>'''This table shows a list of BMPs and associated volume removal mechanisms. Primary (removal) means the BMP was designed for this specific mechanism. Secondary (...")
 
m
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
<font size=3>'''This table shows a list of BMPs and associated volume removal mechanisms. Primary (removal) means the BMP was designed for this specific mechanism. Secondary (removal) means the BMP provides additional removal of pollutants for this mechanism even though the BMP was not designed for that purpose. An empty cell means the BMP provides limited or no removal for that mechanism.'''</font size><br>
+
<font size=3>'''This table shows a list of BMPs and associated volume removal mechanisms. Primary (removal) means the BMP was designed for this specific mechanism. Secondary (removal) means the BMP provides some volume control for this mechanism even though the BMP was not designed for that purpose. An empty cell means the BMP provides limited or no removal for that mechanism.'''</font size><br>
Link to this [[Primary and secondary pollutant removal mechanisms|table]].
+
Link to this [[Primary and secondary volume removal mechanisms|table]].
  
 
<table class="sortable">
 
<table class="sortable">
Line 8: Line 8:
 
</tr>
 
</tr>
 
<tr>
 
<tr>
<th colspan="6"><center>Water quality</center></th>
 
 
<th colspan="4"><center>Water quantity</center></th>
 
<th colspan="4"><center>Water quantity</center></th>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
<th width="9%">Volume control</th>
+
<th width="15%">Volume control</th>
<th width="9%">Rate control</th>
+
<th width="15%">Rate control</th>
<th width="9%">Velocity control</th>
+
<th width="15%">Velocity control</th>
<th width="9%">ET<sup>a</sup></th>
+
<th width="15%">ET<sup>a</sup></th>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
Line 47: Line 46:
 
<td>secondary</td>
 
<td>secondary</td>
 
<td></td>
 
<td></td>
<td><center>secondary</center></td>
+
<td>secondary</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
Line 76: Line 75:
 
<td>secondary</td>
 
<td>secondary</td>
 
</table>
 
</table>
[[category:table]]
+
 
 +
<noinclude>
 +
[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/General bmp information]]
 +
[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Pollutant removal]]
 +
[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Hydrology and geology]]
 +
</noinclude>

Latest revision as of 12:26, 7 August 2022

This table shows a list of BMPs and associated volume removal mechanisms. Primary (removal) means the BMP was designed for this specific mechanism. Secondary (removal) means the BMP provides some volume control for this mechanism even though the BMP was not designed for that purpose. An empty cell means the BMP provides limited or no removal for that mechanism.
Link to this table.

BMP group
Volume removal mechanisms
Water quantity
Volume control Rate control Velocity control ETa
Pollution prevention
Not applicable
Better Site Design/low impact development primary secondary secondary secondary
Runoff volume minimization primary secondary
Temporary construction sediment control primary secondary
Bioretention secondary secondary secondary
Filtration secondary secondary
Infiltration secondary secondary
Stormwater ponds primary primary secondary
Stormwater wetlands primary primary secondary

This page was last edited on 7 August 2022, at 12:26.