(Created page with "<center><font size=3></font size><br> Link to this table</center> <table class="sortable"><tr> <th>BMP group</th> <th>...") |
m |
||
Line 71: | Line 71: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | <font size=1><sup>a</sup | + | <font size=1><sup>a</sup>See section on [[Unified sizing criteria|unified sizing criteria]] for more information<br> |
− | <sup>b</sup | + | <sup>b</sup>Can be incorporated into the structural control in certain situations<br> |
− | <sup>c</sup | + | <sup>c</sup>May be provided by infiltration<br> |
− | <sup>d</sup | + | <sup>d</sup>When impermeable liners are required or pool intercepts groundwater<br> |
<sup>e</sup>Can be included as part of the treatment train</font size> | <sup>e</sup>Can be included as part of the treatment train</font size> |
BMP group | Rechargea | Water qualitya | Channel protectiona | Peak dischargea | Hot spot runoff |
---|---|---|---|---|---|
Bioretention | Varies | Yes | Possibleb | No | Yes. Needs underdrain |
Filtration - media | No | Yes | No | No | Yes |
Filtration - vegetative | Variesc | Yes | Possibleb | No | Yes |
Infiltration trench | Yes | Yes | No | No | No |
Infiltration basin | Yes | Yes | Yes | Yes | No |
Stormwater ponds | Noc | Yes | Yes | Yes | Yes |
Constructed wetlands | Variesc | Yes | Yes | Yes | Yes. Needs pre-treatment |
Supplemental BMPs | Varies | Nob | Possible | No | Noe |
aSee section on unified sizing criteria for more information
bCan be incorporated into the structural control in certain situations
cMay be provided by infiltration
dWhen impermeable liners are required or pool intercepts groundwater
eCan be included as part of the treatment train