m
m
Line 17: Line 17:
 
<td>1</td>
 
<td>1</td>
 
<td>See section on [http://stormwater.pca.state.mn.us/index.php/Potential_stormwater_hotspots Potential stormwater hotspots] for more information</td>
 
<td>See section on [http://stormwater.pca.state.mn.us/index.php/Potential_stormwater_hotspots Potential stormwater hotspots] for more information</td>
 +
</tr>
 +
<tr>
 +
<td>Constructed ponds or constructed wetlands with less than 3 feet separation from seasonally high water table in a potential hotspot</td>
 +
<td>1</td>
 +
<td></td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>

Revision as of 16:35, 2 December 2015

Design process for selecting the appropriate liner level.
Link to this table

Condition Design level Note
Filtration BMP with less than 3 feet of separation to seasonal saturated soil or bedrock 1 Required under the Construction Stormwater permit
BMP in confirmed PSH with high or very high groundwater pollution potential 1 See section on Potential stormwater hotspots for more information
Constructed ponds or constructed wetlands with less than 3 feet separation from seasonally high water table in a potential hotspot 1
Karst terrain with high or very high groundwater pollution potential 1 See section on karst for more information
Maintain permanent pool in areas underlain by geologic material that is fractured or has a high infiltration rate 2
Separation distances cannot be achieved 2
Separate tree BMP from road, parking lot, sidewalk or adjacent walls or building foundation 2 To prevent tree root intrusion. See link