− | <td>BMP in confirmed | + | <td>BMP in confirmed potential stormwater hotspot with high or very high groundwater pollution potential</td> |
<td>1</td> | <td>1</td> | ||
<td>Applies to all [http://stormwater.pca.state.mn.us/index.php/Post-construction_stormwater_Best_Management_Practices post-construction BMPs]. See section on [http://stormwater.pca.state.mn.us/index.php/Potential_stormwater_hotspots Potential stormwater hotspots] for more information</td> | <td>Applies to all [http://stormwater.pca.state.mn.us/index.php/Post-construction_stormwater_Best_Management_Practices post-construction BMPs]. See section on [http://stormwater.pca.state.mn.us/index.php/Potential_stormwater_hotspots Potential stormwater hotspots] for more information</td> |
Design process for selecting the appropriate liner level.
Link to this table
Condition | Design level | Note |
---|---|---|
Filtration BMP with less than 3 feet of separation to seasonal saturated soil or bedrock | 1 | Required under the Construction Stormwater permit |
BMP in confirmed potential stormwater hotspot with high or very high groundwater pollution potential | 1 | Applies to all post-construction BMPs. See section on Potential stormwater hotspots for more information |
Constructed ponds or constructed wetlands with less than 3 feet separation from seasonally high water table in a potential hotspot | 1 | |
Karst terrain with high or very high groundwater pollution potential | 1 | See section on karst for more information |
Maintain permanent pool in constructed ponds or constructed wetlands in areas underlain by geologic material that is fractured or has a high infiltration rate | 2 | |
Separation distances cannot be achieved | 2 | |
Separate tree BMP from road, parking lot, sidewalk or adjacent walls or building foundation | 2 | To prevent tree root intrusion. See link |