CONTECH Engineered Solutions, LLC. The Kraken is an engineered filtration system designed to filter pollutants from stormwater runoff. It is classified as a <span title="A manufactured treatment device (mtd) is a pre-fabricated stormwater treatment structure utilizing settling (sedimentation), filtration, absorptive/adsorptive materials, vortex separation, vegetative components, and/or other appropriate technology to remove pollutants from stormwater runoff. MTDs are typically proprietary devices."> '''manufactured treatment device'''</span> (mtd). | CONTECH Engineered Solutions, LLC. The Kraken is an engineered filtration system designed to filter pollutants from stormwater runoff. It is classified as a <span title="A manufactured treatment device (mtd) is a pre-fabricated stormwater treatment structure utilizing settling (sedimentation), filtration, absorptive/adsorptive materials, vortex separation, vegetative components, and/or other appropriate technology to remove pollutants from stormwater runoff. MTDs are typically proprietary devices."> '''manufactured treatment device'''</span> (mtd). | ||
− | This page provides information on pollutant removal credits for | + | This page provides information on pollutant removal credits for Contech The Kraken, links to supporting information, and links to information on system design, inspection, operation, and maintenance. |
==TP and TSS credits== | ==TP and TSS credits== | ||
− | When conditions described in this section are met, applicable | + | When conditions described in this section are met, applicable Contech The Kraken systems are approved for the following removals for total suspended solids (TSS) and total phosphorus (TP). |
*TSS: 80 percent removal | *TSS: 80 percent removal | ||
*TP: Tier 1 | *TP: Tier 1 | ||
Line 25: | Line 25: | ||
===Configurations=== | ===Configurations=== | ||
− | For a discussion of | + | For a discussion of Contech The Kraken configurations see [https://stormwater.pca.state.mn.us/index.php?title=BioClean_The_Kraken#Links appropriate configurations in the design, installation, and specification documents]. |
===Use conditions=== | ===Use conditions=== | ||
− | To receive the full credit, | + | To receive the full credit, Contech The Kraken systems must comply with the following conditions. |
− | #Design, assemble, install, operate, and maintain | + | #Design, assemble, install, operate, and maintain Contech The Kraken systems in accordance with applicable [https://stormwater.pca.state.mn.us/index.php?title=BioClean_The_Kraken#Links manuals]. |
#The maximum flow rates through the devices are specified below. | #The maximum flow rates through the devices are specified below. | ||
##Basic Treatment: Sized at a hydraulic loading rate of no more than 0.05000 gpm/ft<sup>2</sup> per cartridge. | ##Basic Treatment: Sized at a hydraulic loading rate of no more than 0.05000 gpm/ft<sup>2</sup> per cartridge. | ||
Line 38: | Line 38: | ||
#Systems are designed to treat a specified water quality volume or annual average runoff volume. The annual average runoff treated can be determined using [https://stormwater.pca.state.mn.us/index.php?title=TP_and_TSS_credits_and_guidance_for_manufactured_treatment_devices_(mtds)#Calculating_annual_volume_treated methods that are specified here]. | #Systems are designed to treat a specified water quality volume or annual average runoff volume. The annual average runoff treated can be determined using [https://stormwater.pca.state.mn.us/index.php?title=TP_and_TSS_credits_and_guidance_for_manufactured_treatment_devices_(mtds)#Calculating_annual_volume_treated methods that are specified here]. | ||
#Each site plan must undergo review before approval of the unit for site installation. | #Each site plan must undergo review before approval of the unit for site installation. | ||
− | #The Kraken media shall conform to the specifications described in [https://biocleanenvironmental.com/wp-content/uploads/2021/03/Specifications-Kraken-Filter.pdf Specifications] and shall be sourced from | + | #The Kraken media shall conform to the specifications described in [https://biocleanenvironmental.com/wp-content/uploads/2021/03/Specifications-Kraken-Filter.pdf Specifications] and shall be sourced from Contech Environmental Services, Inc. (A Forterra Company) with no substitutions. |
#Follow maintenance procedures given in the most recent version of the [https://biocleanenvironmental.com/wp-content/uploads/2021/06/Operations-Maintenance-Kraken-Filter.pdf Operation and Maintenance Manual]. | #Follow maintenance procedures given in the most recent version of the [https://biocleanenvironmental.com/wp-content/uploads/2021/06/Operations-Maintenance-Kraken-Filter.pdf Operation and Maintenance Manual]. | ||
− | #Install the | + | #Install the Contech The Kraken in such a manner that flows exceeding the maximum Contech The Kraken operating rate are conveyed around the Contech The Kraken media and will not resuspend captured sediment. |
− | #Discharges from the | + | #Discharges from the Contech The Kraken units shall not cause or contribute to water quality standards violations in receiving waters. |
#When applicable, adhere to use conditions provided in Washington State Department of Ecology's report (Ecology's Conditions of Use) [https://fortress.wa.gov/ecy/ezshare/wq/tape/use_designations/BIOCLEANkrakenGULD.pdf GENERAL USE LEVEL DESIGNATION (GULD) FOR BASIC (TSS) AND PHOSPHORUS For BioClean Environmental Services, Inc’s The Kraken™ Membrane Filter]. Note that some information in this report is specific to Washington State and not applicable to Minnesota. | #When applicable, adhere to use conditions provided in Washington State Department of Ecology's report (Ecology's Conditions of Use) [https://fortress.wa.gov/ecy/ezshare/wq/tape/use_designations/BIOCLEANkrakenGULD.pdf GENERAL USE LEVEL DESIGNATION (GULD) FOR BASIC (TSS) AND PHOSPHORUS For BioClean Environmental Services, Inc’s The Kraken™ Membrane Filter]. Note that some information in this report is specific to Washington State and not applicable to Minnesota. | ||
Line 74: | Line 74: | ||
*[https://biocleanenvironmental.com/technical-downloads?cat=filtration&term=kraken-filter&tech=specifications,standard-details Technical downloads] - Details and other specifications | *[https://biocleanenvironmental.com/technical-downloads?cat=filtration&term=kraken-filter&tech=specifications,standard-details Technical downloads] - Details and other specifications | ||
*[https://biocleanenvironmental.com/news-video/bio-clean-kraken-filter Video link] | *[https://biocleanenvironmental.com/news-video/bio-clean-kraken-filter Video link] | ||
− | *[https://biocleanenvironmental.com/technical-downloads | + | *[https://biocleanenvironmental.com/technical-downloads Contech technical downloads] |
[[Category:Level 3 - Best management practices/Structural practices/Proprietary devices]] | [[Category:Level 3 - Best management practices/Structural practices/Proprietary devices]] |
CONTECH Engineered Solutions, LLC. The Kraken is an engineered filtration system designed to filter pollutants from stormwater runoff. It is classified as a manufactured treatment device (mtd).
This page provides information on pollutant removal credits for Contech The Kraken, links to supporting information, and links to information on system design, inspection, operation, and maintenance.
When conditions described in this section are met, applicable Contech The Kraken systems are approved for the following removals for total suspended solids (TSS) and total phosphorus (TP).
For more information on credits, see TP and TSS credits and guidance for manufactured treatment devices (mtds)
For a discussion of Contech The Kraken configurations see appropriate configurations in the design, installation, and specification documents.
To receive the full credit, Contech The Kraken systems must comply with the following conditions.
Credits apply only to the water being treated by a device. The applicable treatment volume must be determined using one of the methods described here.
The Tier 1 credit equals the TAPE-approved credits. Tier 2 credit was determined by analyzing water quality data collected at the Lake Union Ship Canal Test Facility in Seattle, WA. The site consisted of 1.69 acres of impervious surface from parking and roadways areas. The unit size was 6 X 11 feet.
MPCA compiled data from General Use Level Designation Technical Evaluation Report. Below are summary statistics for the device.
TAPE means and medians represent values meeting TAPE criteria for TP (inflow concentrations of 0.1 to 0.5 mg/L) and TSS (inflow concentrations greater than 20 mg/L). Of the 14 samples, TAPE medians and means represent 10 samples for TP and 13 samples for TSS.
Meet the conditions specified for the appropriate TP and/or TSS credit.
Meet the following conditions, unless conditions for the appropriate TP and/or TSS credit are more stringent.