Line 41: Line 41:
 
<tr>
 
<tr>
 
<td>Compare TSS/TP removal rate to typical [https://stormwater.pca.state.mn.us/index.php?title=Typical_BMP_TSS_and_TP_removal_rates_from_Minnesota_Stormwater_Manual tabled values]</td>
 
<td>Compare TSS/TP removal rate to typical [https://stormwater.pca.state.mn.us/index.php?title=Typical_BMP_TSS_and_TP_removal_rates_from_Minnesota_Stormwater_Manual tabled values]</td>
<td>Calculate pollutant removal (%) as described in <font color="red">Table 41</font>. Note: must have junction elements upstream and downstream of all control practices</td>
+
<td>Calculate pollutant removal (%) as described [https://stormwater.pca.state.mn.us/index.php?title=Using_WinSLAMM_to_generate_load_reduction_and_WLA_reporting_terms here]. Note: must have junction elements upstream and downstream of all control practices</td>
 
</tr>
 
</tr>
 
</table>
 
</table>

Revision as of 18:59, 6 September 2019

General WinSLAMM result QAQC list
Link to this table

QA/QC review item Related WinSLAMM output
Confirm total watershed area is correct Output Summary → Total Area Modeled (ac)
Confirm area modeled in each land uses is correct Review land use summary table shown in the main model space window
Confirm source areas or applied SLUs are correct for each land use Review source area modeling assumptions for each land use
Confirm correct number of control devices modeled in drainage network and source areas Review control practice summary table shown in the main model space window
Confirm correct parameters modeled in control practices Review parameters applied in control practice parameter window for all modeled drainage area and source area control practices
Confirm land use, junction, and device routing Review routing in main model space window
Confirm precipitation event totals are correct Review precipitation dates and rainfall depth totals. Can be accessed through a number of output tabs including "Junction → Runoff Volume"
Compare source area outflow pollutant concentration to tabled values Output: Land Uses → Pollutants → Concentration (mg/L)
Compare TSS/TP removal rate to typical tabled values Calculate pollutant removal (%) as described here. Note: must have junction elements upstream and downstream of all control practices