Line 13: Line 13:
 
<td rowspan="2">Bioretention<sup>f</sup></td>
 
<td rowspan="2">Bioretention<sup>f</sup></td>
 
<td>Underdrain</td>
 
<td>Underdrain</td>
<td>50</td>
+
<td>see [[Phosphorus credits for bioretention systems with an underdrain]]
<td>65</td>
+
</td>
<td>0</td>
+
<td>see [[Phosphorus credits for bioretention systems with an underdrain]]</td>
 +
<td>see [[Phosphorus credits for bioretention systems with an underdrain]]</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
 
<td>Infiltration<sup>h</sup></td>
 
<td>Infiltration<sup>h</sup></td>
<td>100</td>
+
<td>
<td>100</td>
+
*100 for infiltrated portion
<td>100</td>
+
*0 for non-infiltrated portion</td>
 +
<td>
 +
*100 for infiltrated portion
 +
*0 for non-infiltrated portion</td>
 +
<td>
 +
*100 for infiltrated portion
 +
*0 for non-infiltrated portion</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
Line 32: Line 39:
 
<tr>
 
<tr>
 
<td>Dry swale</td>
 
<td>Dry swale</td>
<td>0</td>
+
<td>see [[Phosphorus credits for bioretention systems with an underdrain]]</td>
<td>55</td>
+
<td>see [[Phosphorus credits for bioretention systems with an underdrain]]</td>
<td>0</td>
+
<td>see [[Phosphorus credits for bioretention systems with an underdrain]]</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
 
<td>Wet swale</td>
 
<td>Wet swale</td>
<td>65</td>
+
<td>0</td>
<td>75</td>
+
<td>35</td>
<td>70</td>
+
<td>0</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
 
<td rowspan="2">Infiltration<sup>f</sup></td>
 
<td rowspan="2">Infiltration<sup>f</sup></td>
 
<td>Infiltration trench<sup>h</sup></td>
 
<td>Infiltration trench<sup>h</sup></td>
<td>100</td>
+
<td>
<td>100</td>
+
*100 for infiltrated portion
<td>100</td>
+
*0 for non-infiltrated portion</td>
 +
<td>
 +
*100 for infiltrated portion
 +
*0 for non-infiltrated portion</td>
 +
<td>
 +
*100 for infiltrated portion
 +
*0 for non-infiltrated portion</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
 
<td>Infiltration basin<sup>h</sup></td>
 
<td>Infiltration basin<sup>h</sup></td>
<td>100</td>
+
<td>
<td>100</td>
+
*100 for infiltrated portion
<td>100</td>
+
*0 for non-infiltrated portion</td>
 +
<td>
 +
*100 for infiltrated portion
 +
*0 for non-infiltrated portion</td>
 +
<td>
 +
*100 for infiltrated portion
 +
*0 for non-infiltrated portion</td>
 
</tr>
 
</tr>
 
<tr>
 
<tr>
 
<td rowspan="2">Stormwater ponds</td>
 
<td rowspan="2">Stormwater ponds</td>
 
<td>Wet pond</td>
 
<td>Wet pond</td>
<td>50</td>
+
<td>46</td>
<td>65</td>
+
<td>75</td>
 
<td>0</td>
 
<td>0</td>
 
</tr>
 
</tr>
Line 71: Line 90:
 
<td rowspan="2">Stormwater wetlands</td>
 
<td rowspan="2">Stormwater wetlands</td>
 
<td>Shallow wetland</td>
 
<td>Shallow wetland</td>
<td>40</td>
+
<td>38</td>
 
<td>55</td>
 
<td>55</td>
 
<td>0</td>
 
<td>0</td>
Line 77: Line 96:
 
<tr>
 
<tr>
 
<td>Pond/wetland</td>
 
<td>Pond/wetland</td>
<td>55</td>
+
<td></td>
<td>75</td>
+
<td></td>
 
<td>0</td>
 
<td>0</td>
 
</tr>
 
</tr>
Line 96: Line 115:
 
<sup>h</sup>Note that 100% is assumed for all infiltration, but only for that portion of the flow fully treated in the infiltration facility; by-passed runoff or runoff diverted via underdrain does not receive this level of treatment.</font size>
 
<sup>h</sup>Note that 100% is assumed for all infiltration, but only for that portion of the flow fully treated in the infiltration facility; by-passed runoff or runoff diverted via underdrain does not receive this level of treatment.</font size>
  
<noinclude>[[category:table]]</noinclude>
+
<noinclude>
 +
[[Category:Level 2 - Pollutants/Pollutant removal]]
 +
[[Category:Level 3 - General information, reference, tables, images, and archives/Tables/Pollutant removal]]
 +
</noinclude>

Latest revision as of 19:48, 1 August 2022

This table shows comparison of phosphorus removal for different BMPs.a,e,f Values represent the percent of incoming pollutant that is removed. Source: MPCA Minnesota Stormwater Manual.
Link to this table

Information: Removal rates shown here are composite averages intended solely for use in comparing performance between BMP designs and for use in calculating load reduction in site-based TP models. They have been adapted, rounded and slightly discounted from statistical values published in BMP performance databases.
BMP group BMP design variation Average TP removal rate (%)b Maximum TP removal rate (%)c Average soluble P removal rate (%)d,f,g
Bioretentionf Underdrain see Phosphorus credits for bioretention systems with an underdrain see Phosphorus credits for bioretention systems with an underdrain see Phosphorus credits for bioretention systems with an underdrain
Infiltrationh
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
Filtration Sand filter 50 55 0
Dry swale see Phosphorus credits for bioretention systems with an underdrain see Phosphorus credits for bioretention systems with an underdrain see Phosphorus credits for bioretention systems with an underdrain
Wet swale 0 35 0
Infiltrationf Infiltration trenchh
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
Infiltration basinh
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
  • 100 for infiltrated portion
  • 0 for non-infiltrated portion
Stormwater ponds Wet pond 46 75 0
Multiple pond 60 75 0
Stormwater wetlands Shallow wetland 38 55 0
Pond/wetland 0

aRemoval rates show in table are a composite of five sources:

  • Caraco (Center for Watershed protection, 2001)
  • Maryland Department of the Environment](2000)
  • Winer (Center for Watershed Protection, 2000)
  • P8 modeling (William Walker)

b Average removal efficiency expected under MPCA Sizing Rules 1 and 3
c Upper limit on phosphorus removal with increased sizing and design features, based on national review
d Average rate of soluble phosphorus removal in the literature
e See section on calculating credits for each BMP in this Manual.
f Note that the performance numbers apply only to that portion of total flow actually being treated; it does not include any runoff that bypasses the BMP
gNote that soluble P can transfer from surface water to groundwater, but this column refers only to surface water
hNote that 100% is assumed for all infiltration, but only for that portion of the flow fully treated in the infiltration facility; by-passed runoff or runoff diverted via underdrain does not receive this level of treatment.

This page was last edited on 1 August 2022, at 19:48.