Common problems and how to troubleshoot them for vegetated filter strips
Link to this table
Symptom | Possible Causes | Solution |
---|---|---|
Channelization of flow | Improper grading | Install infiltration trench or level gravel spreader trench upstream of practice |
Erosion | Improper (too steep) grading and/or plant loss | Correct for drainage and flow path issues to make sure flows are evenly distributed. Make sure the flow paths are unobstructed |
Vegetation is not able to establish | Plant selection is inappropriate for the site | Consult with a landscaper or horticulturist. Check that plants are suited to the local conditions. Make sure BMP is protected from snow storage or salt application. |