==TP and TSS credits== | ==TP and TSS credits== | ||
When conditions described in this section are met, applicable Contech Filterra systems are approved for the following pollutant removals. | When conditions described in this section are met, applicable Contech Filterra systems are approved for the following pollutant removals. | ||
− | *TSS credit: | + | *TSS credit: 82 percent |
− | *Tier 1 | + | *TP: Tier 1 |
**Credit: 50 percent reduction | **Credit: 50 percent reduction | ||
**Conditions for receiving credit: Inspect manufactured treatment device a minimum of twice per year.1 Conduct inspections following manufacturer’s instructions/recommendations. Use maintenance indicators provided by manufacturers to determine if maintenance is needed.2 Maintenance procedures should follow manufacturer’s guidelines. | **Conditions for receiving credit: Inspect manufactured treatment device a minimum of twice per year.1 Conduct inspections following manufacturer’s instructions/recommendations. Use maintenance indicators provided by manufacturers to determine if maintenance is needed.2 Maintenance procedures should follow manufacturer’s guidelines. | ||
− | *Tier 2 | + | *TP: Tier 2 |
**Credit: based on an assessment of 95% lower confidence limits (LCLs) for the device (see discussion below) | **Credit: based on an assessment of 95% lower confidence limits (LCLs) for the device (see discussion below) | ||
**Conditions for receiving credit: To receive this credit the device must meet Tier 1 conditions and the following conditions. | **Conditions for receiving credit: To receive this credit the device must meet Tier 1 conditions and the following conditions. | ||
***DP should be 25 percent or less of TP. If site specific monitoring data do not exist to verify this, acceptable land uses include <span title="Commercial land use is the use of land for commercial purposes including building offices, shops, resorts and restaurants as opposed to construction of a residential house"> '''commercial land use'''</span>, <span title="Land used for commercial establishments, manufacturing plants, public utilities, mining, distribution of goods or services, administration of business activities, research and development facilities, warehousing, shipping, transporting, remanufacturing, stockpiling of raw materials, storage, repair and maintenance of commercial machinery or equipment, and waste management"> '''industrial land use'''</span>, <span title="This land use includes major transportation corridors where the land use is exclusively transportation. These areas are typically highly impervious and may include only small vegetated areas consisting of swales or medians, and relatively small right-of-way areas. This land use does not include arterial streets in residential, commercial, and industrial areas."> '''transportation land use'''</span>, <span title="Highly urban and ultra-urban settings have a large percentage of impermeable surface and typically have limited space to install surface BMPs. An example would be a downtown area."> '''highly urban and ultra-urban environments'''</span> (ultra-urban), or combinations of these. The credit should not be applied in <span title="Residential land use means any real property or portion thereof which is used for housing human beings. This term includes property used for schools, day care centers, nursing homes, or other residential-style facilities or recreational areas"> '''residential land use'''</span>, to roof runoff, areas with extensive tree canopy, or other areas where dissolved phosphorus is likely to exceed 25 percent of total phosphorus ([https://stormwater.pca.state.mn.us/index.php?title=Event_mean_concentrations_of_total_and_dissolved_phosphorus_in_stormwater_runoff#Ratios_of_particulate_to_dissolved_phosphorus link here for discussion of dissolved phosphorus ratios]). Site specific monitoring data collected using following appropriate QA/QC protocols may be used to establish DP:TP ratios. | ***DP should be 25 percent or less of TP. If site specific monitoring data do not exist to verify this, acceptable land uses include <span title="Commercial land use is the use of land for commercial purposes including building offices, shops, resorts and restaurants as opposed to construction of a residential house"> '''commercial land use'''</span>, <span title="Land used for commercial establishments, manufacturing plants, public utilities, mining, distribution of goods or services, administration of business activities, research and development facilities, warehousing, shipping, transporting, remanufacturing, stockpiling of raw materials, storage, repair and maintenance of commercial machinery or equipment, and waste management"> '''industrial land use'''</span>, <span title="This land use includes major transportation corridors where the land use is exclusively transportation. These areas are typically highly impervious and may include only small vegetated areas consisting of swales or medians, and relatively small right-of-way areas. This land use does not include arterial streets in residential, commercial, and industrial areas."> '''transportation land use'''</span>, <span title="Highly urban and ultra-urban settings have a large percentage of impermeable surface and typically have limited space to install surface BMPs. An example would be a downtown area."> '''highly urban and ultra-urban environments'''</span> (ultra-urban), or combinations of these. The credit should not be applied in <span title="Residential land use means any real property or portion thereof which is used for housing human beings. This term includes property used for schools, day care centers, nursing homes, or other residential-style facilities or recreational areas"> '''residential land use'''</span>, to roof runoff, areas with extensive tree canopy, or other areas where dissolved phosphorus is likely to exceed 25 percent of total phosphorus ([https://stormwater.pca.state.mn.us/index.php?title=Event_mean_concentrations_of_total_and_dissolved_phosphorus_in_stormwater_runoff#Ratios_of_particulate_to_dissolved_phosphorus link here for discussion of dissolved phosphorus ratios]). Site specific monitoring data collected using following appropriate QA/QC protocols may be used to establish DP:TP ratios. | ||
***Inspect manufactured treatment device monthly during the frost free season for the first year of operation after construction. Conduct inspections following manufacturer’s instructions/recommendations. Use maintenance indicators provided by manufacturers to determine if maintenance is needed. Maintenance procedures should follow manufacturer’s guidelines. Determine future inspection and maintenance schedules from findings during the first year of operation. | ***Inspect manufactured treatment device monthly during the frost free season for the first year of operation after construction. Conduct inspections following manufacturer’s instructions/recommendations. Use maintenance indicators provided by manufacturers to determine if maintenance is needed. Maintenance procedures should follow manufacturer’s guidelines. Determine future inspection and maintenance schedules from findings during the first year of operation. | ||
− | *Tier 3 | + | *TP: Tier 3 |
**Credit: based on an assessment of medians for the device (see discussion below) | **Credit: based on an assessment of medians for the device (see discussion below) | ||
**Conditions for receiving credit: To receive this credit the device must meet Tier 1 and Tier 2 conditions the following conditions. | **Conditions for receiving credit: To receive this credit the device must meet Tier 1 and Tier 2 conditions the following conditions. |
Contech's Filterra is an engineered bioretention system designed to filter pollutants from stormwater runoff. This page provides information on pollutant removal credits for Filterra, links to supporting information, and links to information on system design, inspecion, operation, and maintenance.
When conditions described in this section are met, applicable Contech Filterra systems are approved for the following pollutant removals.
For more information on credits, see TP and TSS credits and guidance for manufactured treatment devices (mtds)
Applicable configurations (systems) include
To receive the full credit, Filterra systems must comply with the following conditions.
Credits apply only to the water being treated by a device. The applicable treatment volume must be determined using one of the methods described here.
The Tier 1 credit equals the TAPE-approved credits. Tier 2 and Tier 3 credits were determined by analyzing water quality data collected at Bellingham, Washington. The site consisted of residential land use with 0.4 acres of impervious draining to the device. The device was 4 ft by 6.5 ft, with a filter media depth of 1.8 feet and a ponding depth of 0.75 feet.
MPCA compiled data from Appendix K of the report TECHNICAL EVALUATION REPORT - FILTERRA SYSTEM PHOSPHORUS TREATMENT AND SUPPLEMENTAL BASIC TREATMENT PERFORMANCE MONITORING. Summary statistics are shown in the adjacent image. TAPE means and medians represent values meeting TAPE criteria for TP (inflow concentrations of 0.1 to 0.5 mg/L) and TSS (inflow concentrations greater than 20 mg/L). Thus, of the 22 samples, TAPE medians and means represent 10 samples for TP and 18 samples for TSS, while the remaining data in the figure are for all 22 events.
The 95% boot strap LCL is 52% for all data and 69% for TAPE analyzed data. TP removal decreases as the inflow concentration decreases below 0.1. However, if we consider only TP values > 0.05 mg/L, the LCL is 58.9 percent. TP concentrations of 0.05 mg/L or less are uncommon in Minnesota. Consequently, the recommended Tier 2 value is 58%. The median removal for all data was 67% and for TAPE-analyzed data was 78.5%. The recommended Tier 2 value is 65%.
Phosphorus removal, as a percent of influent TP, decreased as influent TP concentration decreased below 0.1 mg/L and as the ratio of Dissolved P:TP increased. For a discussion of effects of these factors on crediting, link here.
To link to the Excel spreadsheet containing water monitoring data click here - File:Water quality data for MTDs Feb 4.xlsx