m |
m |
||
Line 11: | Line 11: | ||
<font size=4>[[Acknowledgements for pretreatment|Acknowledgements]]</font size> | <font size=4>[[Acknowledgements for pretreatment|Acknowledgements]]</font size> | ||
− | + | *[[Overview and methods of pretreatment]] | |
− | + | *Overviews for different types of pretreatment practices | |
− | + | **[[Overview for pretreatment settling devices]] | |
− | + | **[[Overview for pretreatment screens]] | |
− | + | **[[Overview for pretreatment vegetated filter strips]] | |
− | + | *Information for specific types of pretreatment practices | |
**[[Design, construction, operation and maintenance specifications for pretreatment vegetated filter strips]] | **[[Design, construction, operation and maintenance specifications for pretreatment vegetated filter strips]] | ||
+ | **[[Pretreatment - Hydrodynamic separation devices]] | ||
+ | **[[Pretreatment - Screening and straining devices, including forebays]] | ||
+ | **[[Pretreatment - Above ground and below grade storage and settling devices]] | ||
+ | **[[Pretreatment - Filtration devices and practices]] | ||
+ | **[[Pretreatment - Other pretreatment water quality devices and practices]] | ||
+ | *[[Pretreatment - Additional considerations]] | ||
*[[Case studies for pretreatment]] | *[[Case studies for pretreatment]] | ||
*[[References for pretreatment]] | *[[References for pretreatment]] | ||
Line 24: | Line 30: | ||
*[[Supporting material for pretreatment]] | *[[Supporting material for pretreatment]] | ||
*[[Photo gallery for pretreatment]] | *[[Photo gallery for pretreatment]] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
The following page was previously included in this pretreatment section of the manual. Much of this information has been updated and the reader is encouraged to use the information in the updated sections, shown in the above Table of Contents. However, there may be some useful information on this page. We hope to eventually update the information on this page. [[Flow-through structures for pre-treatment]] | The following page was previously included in this pretreatment section of the manual. Much of this information has been updated and the reader is encouraged to use the information in the updated sections, shown in the above Table of Contents. However, there may be some useful information on this page. We hope to eventually update the information on this page. [[Flow-through structures for pre-treatment]] |
The Manual user will notice that many of the stormwater practices discussed in this Manual recommend pretreatment as an integral part of the BMP application. In fact, in many applications (ex. infiltration, stormwater ponds), the BMP would not be properly used if pre-treatment is ignored. The simple reason for the use of pretreatment techniques is the necessity to keep a BMP from being overloaded, primarily by sediment. Pretreatment can also be used to dampen the effects of high or rapid inflow, dissipate energy, and provide additional storage. All of these ancillary benefits help BMP performance.
Pretreatment is a required part of infiltration and filtration practices covered under the Minnesota Construction Stormwater General Permit. This manual describes three general types of pretreatment practices - settling devices, screens, and vegetated filter strips. These are described on the pages below.
The following page was previously included in this pretreatment section of the manual. Much of this information has been updated and the reader is encouraged to use the information in the updated sections, shown in the above Table of Contents. However, there may be some useful information on this page. We hope to eventually update the information on this page. Flow-through structures for pre-treatment